INTRODUCTIONS
1. Power module incorporates an IEC connector, single or double-
fuse (IEC 5 x 20mm or 3AG 6.3 x32mm) holder, optional voltage
selector switch and double-pole power switch, plus an EMI filter
all-in-one easy-to-install unit.
2. Adapts to 110-120V or 220-240V input voltage by simply
reversing the fuse cartridge.
3. All part numbers are UL recognized, CSA certified and VDE
approved.
COMPONENTS
V
D
E
PART NO.
L (mH)
Cx (uF)
03EB3
03EB3A
8
03EB3S
03EB3SA
06EB3
06EB3A
2.5
0.22
06EB3S
06EB3SA
10EB3
10EB3A
10EB3S
1.6
10EB3SA
Lg: 400 uH (EB3A 5B3SA only)
TYPE & FEATURE
DELTA PART NO.
FUSE
IEC CONNECTOR
DOUBLE POLE POWER SWITCH
VOLTAGE SELECTOR SW
ELECTRICAL SCHEMATIC
UL, CSA & VDE approved current rating: UL 10A both at 125VAC & 250V AC;
CSA & VDE-6A at 250VAC.
UL, CSA & VDE approved current rating: UL & CSA 10A both at 125VAC & 250V AC;
_
VDE 10A at 250VAC.
Electrical lifetime: 10,000 cycles.
Maximum inrush current: 70A.
ELECTRICAL SCHEMATIC
SW
L
L
Cy
Cx
R
I
L
N
E
Cy
N
G
FIG. A
POWER ENTRY MODULE EMI FILTERS
Cy (pF)
R ( )
3300
1M
03EB3
03EB3A
05EB3B
06EB3
06EB3A
10EB3
10EB3A
DOUBLE
DOUBLE
FIG. A
FIG. B
_
_
1
F
2
110V
L
O
A
D
110V
3
G'
4
FOR XXEB3S
SPECIFICATIONS
1. Maximum leakage current each
line-to-ground @ 115VAC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.45mA
2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
3. Operating frequency: 50/60Hz
4. Rated voltage: 115/250VAC
V
D
E
PART NO.
L (mH)
05EB3B/S
0.93
03EB3S
03EB3SA
05EB3BS
06EB3S
06EB3SA
10EB3S
10EB3SA
SINGLE
SINGLE
FIG. A
FIG. B
SW
L
L
Cx
R
I
L
N
E
N
G
Lg
4-8
Cx (uF)
Cy (pF)
R ( )
0.01
2200
1M
1
F
2
Cy
L
O
A
Cy
D
3
4
G'
FOR XXEB3SA
EB3A, EB3SA
FIG. B
110V
110V

Advertisement

loading

Summary of Contents for Delta Electronics Extension Drive Board EB Series

  • Page 1 SERIES POWER ENTRY MODULE EMI FILTERS INTRODUCTIONS 1. Power module incorporates an IEC connector, single or double- fuse (IEC 5 x 20mm or 3AG 6.3 x32mm) holder, optional voltage selector switch and double-pole power switch, plus an EMI filter all-in-one easy-to-install unit. 2.
  • Page 2 INSERTION LOSS (TYPICAL) 03EB3 COMMON MODE 06EB3 COMMON MODE 80 dB 60 dB 40 dB 20 dB 0 dB 100K MINIMUM INSERTION LOSS IN dB COMMON MODE (L-G) IN 50 OHM SYSTEM CURRENT FREQUENCY-MHz RATING 0.05 0.10 0.15 0.50 1.0 3A (S) 6A (S) 10A (S)