GRASS SENSOMATIC P600M Assembly And Operating Instructions Manual

Hide thumbs Also See for SENSOMATIC P600M:

Advertisement

Quick Links

GRASS SENSOMATIC
GRASS SENSOMATIC
Assembly and operating instructions
19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SENSOMATIC P600M and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GRASS SENSOMATIC P600M

  • Page 1 GRASS SENSOMATIC GRASS SENSOMATIC Assembly and operating instructions...
  • Page 2: Table Of Contents

    GRASS SENSOMATIC Table of contents 1.0 Introduction ......................21 1.1 Instructions for installers ..................21 1.2 Signs and symbols in this instruction manual ............21 1.3 Correct use ......................21 2.0 Safety instructions .................... 22 2.1 General information ....................22 2.2 Safety instructions for assembly ................22 2.3 General safety instructions ..................22...
  • Page 3: Introduction

    This sign indicates the description of the result of an action. 1.3 Correct use The components of a GRASS Sensomatic electro-mechanic opening system may only be used as described under Correct use. I.e. they must be connected to the power supply and operated as described in the assem- bly and operating instructions.
  • Page 4: Safety Instructions

    GRASS GmbH excludes all liability for unauthorised changes to GRASS Sensomatic opening systems and any resulting damage. GRASS GmbH provides a warranty only for the drawer and slide systems Nova Pro, DWD XP and Dynapro. However GRASS GmbH cannot accept any liability for combinations with products of other manufacturers.
  • Page 5: Repairs And Modifications

    Ensure that cables and the opening unit do not come into contact with moving parts. 2.4 Repairs and modifications Ensure repairs and modifications to the GRASS Sensomatic opening system is only performed by an author- ised expert. Live components! Never open the power supply unit or an opening unit! 3.0 Functional description...
  • Page 6: System Overview

    GRASS SENSOMATIC 4.0 System overview Drive unit Connection cable Opening lever Power supply unit Locking lever Power supply cable Frame cable Spring-loaded front buffers...
  • Page 7: Initial Start Up

    GRASS SENSOMATIC 5.0 Initial start up Plug frame and connection cable into the power supply unit Connect adjacent cabinets with the connection cables Connect power supply unit to socket...
  • Page 8: Troubleshooting

    GRASS SENSOMATIC 6.0 Troubleshooting The drawers can always be opened manually like conventional drawers, even when de- energised. It is often helpful to disconnect the system from the mains. Wait 10 seconds before switching the system on again. Fault Cause...
  • Page 9 GRASS SENSOMATIC Fault Cause Remedy The drawers of the Connection cable is not Check that the power cable is seated entire cabinet do not plugged in or is defective firmly, or have it replaced by an author- open ised expert When contacting an authorised expert, have the following information ready: Part number F121...
  • Page 10: Maintenance And Care Instructions

    GRASS SENSOMATIC 7.0 Maintenance and care instructions 7.1 Maintenance The GRASS Sensomatic drawer system does not require maintenance. 7.2 Care instructions Live components! Electric shock! Defect of the opening unit Disconnect the drawer system from the mains before cleaning the drawers!
  • Page 11: Replacement Of The Opening Unit

    GRASS SENSOMATIC 8.0 Replacement of the opening unit Dismounting the opening unit Live components! Electric shock! Disconnect the power supply unit from the mains before opening the locking lever!
  • Page 12: Mounting The Opening Unit

    GRASS SENSOMATIC 8.1 Mounting the opening unit 1. left-hand side: attach 2. right-hand side: clip on)
  • Page 13: Installation Dimensions

    GRASS SENSOMATIC 9.0 Installation dimensions 9.1 Nova Pro installation dimensions 9.2 DWD XP installation dimensions...
  • Page 14: Dynapro Installation Dimensions

    GRASS SENSOMATIC 9.3 Dynapro installation dimensions 10.0 Adjusting the opening force High Medium...
  • Page 15: Technical Data

    GRASS SENSOMATIC 11.0 Technical data 11.1 Power supply unit for up to 30 opening units Scope of application Movement Systems Nova Pro, Dynapro, DWD XP Range of application Only in dry indoor environments Power supply unit Power supply 100 to 240 V...