It serves as a "data sheet" for configuring and integrating a device within a networked system. EDS files can be downloaded from Cognex.com. The recommended way to obtain resources for your device is to use the DataMan WebUI. Open your web browser and navigate to the assigned IP address of your device.
Page 4
DM AOPs that are available that we will demonstrate how to configure in this document. AOP files can be downloaded from Cognex.com. The recommended way to obtain resources for your device is to use the DataMan WebUI. Open your Web Browser and navigate to the assigned IP Address of your device.
Quick Start Guide for DataMan 290/390 and Rockwell PLC Communications PLC Setup Create a Rockwell Project 1. Open Rockwell Studio 5000. 2. Select Create - New Project. 3. Select your PLC from the list, enter a Name for your project and click the Next button.
Quick Start Guide for DataMan 290/390 and Rockwell PLC Communications EDS Installation Make sure you are Offline. 1. From Rockwell Studio 5000, open the Tools menu and select EDS Hardware Installation Tool from the list. 2. Click the Next button.
Page 10
Quick Start Guide for DataMan 290/390 and Rockwell PLC Communications 3. Select the radio button to Register a device description file(s) and click the Next button. 4. Select the 02A6030505390100.eds file from your copied folder and click the Open button.
Quick Start Guide for DataMan 290/390 and Rockwell PLC Communications DataMan WebUI Communications Section 1. Open a Web Browser and enter the IP Address of your DM290. 2. Navigate to Step 4 Communications. 3. Select the EtherNet/IP radio button to enable EtherNet/IP and click the Apply button.
Quick Start Guide for DataMan 290/390 and Rockwell PLC Communications Verify EDS Installation After the DM290 has rebooted go to Rockwell Studio 5000. 1. Open the Communications menu and select Who Active from the list. 2. Confirm the DM290 is on the correctly assigned IP Address.
Quick Start Guide for DataMan 290/390 and Rockwell PLC Communications AOP Installation Make sure all Rockwell Software is shut down to not interfere with the installation. 1. Run the MPSetup.exe application from the Downloaded and Extracted folder. 2. Click the Next button.
Quick Start Guide for DataMan 290/390 and Rockwell PLC Communications Add a Camera to PLC Network Devices Confirm the PLC is Offline. 1. Open Rockwell Studio 5000. 2. From the Controller Organizer menu, navigate to I/O Configuration – Ethernet. 3. Right click on Ethernet and select New Module from the fly-out list.
Page 21
Quick Start Guide for DataMan 290/390 and Rockwell PLC Communications 8. Enter a unique name for the AOP (e.g., DM290). 9. Add a Description. 10. Set the Ethernet Address to the camera’s IP address. 11. To edit the Module Definition, click the Change button.
Quick Start Guide for DataMan 290/390 and Rockwell PLC Communications What is RPI? Requested Packet Interval is a setting used in industrial protocols like EtherNet/IP and DeviceNet to determine how often data is exchanged between a Controller (PLC) and a Device (like a sensor) on the network.
Page 24
Quick Start Guide for DataMan 290/390 and Rockwell PLC Communications AOP Verification You should now see your device listed. Verify Your I/O Data Structure in the Controller Tags as shown below. 1. Select Controller Tags and scroll to your DM290.
Page 25
Quick Start Guide for DataMan 290/390 and Rockwell PLC Communications Trigger Camera Verification 1. Open a Web Browser and enter the IP Address of your DM290 to open the Cognex DataMan WebUI. 2. Navigate to Step 5 Runtime. 3. Ensure your Runtime looks like this image.
Page 26
Quick Start Guide for DataMan 290/390 and Rockwell PLC Communications 4. In Rockwell Studio 5000, go Online with the PLC. 5. Go to the Monitor Tags tab and expand the DM290:O setting. 6. Expand the DM290:0.Control setting. 7. Set Control.TriggerEnable to 1.