80W DALI D4i DT8 NFC LED Driver(Constant Current)
+
2
Important: Read All Instructions Prior to Installation
Function introduction
AC/DC power
input
GND
ACN/
DC-
DALI DIMMABLE DRIVER
ACL/
DC+
PUSH DIM
DA
N
DA
DA
L
DA
DALI signal input
AC Push input
Product Data
LED Channel
DC Voltage
Current
Output
Current Accuracy
Rated Power
Voltage Range
Frequency Range
Power Factor (Typ.)
Total Harmonic
Distortion
Efficiency (Typ.)
Input
AC Current (Typ.)
Inrush Current (Typ.)
Leakage Current
Standby Power Consumption
Anti Surge
Dimming Interface
Dimming Range
Control
Dimming Method
Dimming Curve
2
50-220V
350-700mA via NFC setting; Min.current gear lower to 0.1mA
±3%@ full load
Max. 80W
220-240VAC/VDC
0/50/60Hz
> 0.98 @ 230VAC Full load
THD ≤ 12% (@ full load / 230VAC)
>91% @ 230VAC full load
0.42A @ 230VAC
Max. 26.1A at 230VAC; 280μs duration
< 5mA /230VAC
<0.5W
L-N:1KV/ L-N-G: 2KV
DALI Device Type 8 (DALI consumption < 2mA)/ AC Push
0.01%-100%@ Max current
Amplitude/CCR dimming
Linear/ Logarithmic optional
Short Circuit
Over Current
Protection
Over Temperature
Working Temp.
Max. Case Temp.
Environment
Working Humidity
Storage Temp.
Safety Standards
WW+
WW-
Withstand Voltage
CW+
CW-
Safety &
Isolation Resistance
EMC
EMC Emission
LED Output
EMC Immunity
Others
DALI Infos
Parameter
DALI Interface Standard
Dimming Range
DA1, DA2 High Level
DA1, DA2 Low Level
DA1, DA2 Current
Bus Power Supply Voltage
Bus Power Supply Current
• In compliance with IEC 62386-101:2014, IEC 62386-102:2014, IEC 62386-207 Ed2, IEC 62386-209
• Built-in DALI-2 interface, DALI DT8 device
• Dimmable LED driver with linear metal housing. Max. output power 80W
• 350-700mA current selectable via NFC program tool. Min.current gear lower to 0.1mA
• DALI Address/Group/Scene setting via NFC program tool.
• For luminaires of protection class I and protection class II
• High power factor and efficiency. Non-SELV rated driver
• To switch and dim LED lighting luminaries, Tunable White control
• Amplitude/CCR dimming, smooth and deep dimming
• Compatible with universal DALI masters that support DT8 commands
• DALI-250/251/252/253 Enabled,DALI data inside.
• IP20 rating, suitable for indoor LED lighting applications
• 5 years warranty
Yes, recovers automatically after fault condition is removed
Yes, recovers automatically after fault condition is removed
Yes, recovers automatically after temperature drop
10% ~ 95% RH non-condensing
-40℃ ~ +80℃, 10% ~ 95% RH
& Humidity
EN61347-1, EN61347-2-13, GB/T 19510.1-2023, GB/T 19510.213-2023
I/P-FG: 1500VAC, I/P-DA: 1500VAC, O/P-DA: 1500VAC
I/P-FG: 100M Ohms / 500VDC / 25°C / 70% RH
EN55015, EN61000-3-2, EN61000-3-3, GB 17625.1-2022, GB/T 17743-2021
EN61547, EN61000-4-2,3,4,5,6,8,11
191350H, MIL-HDBK-217F @ 230VAC full load
MTBF
and 25℃ ambient temperature
Dimension
285x30x21mm (L*W*H)
Warranty
Min.
IEC62386-101, 102, 209, 250, 251, 252, 253
0.1%
Logarithmic (default)
9.5V
-6.5V
0
12Vdc
/
-25℃ ~ +60℃
Tc=90℃
5 Years
Typ.
Max.
100%
16V
22.5V
0
6.5V
2mA
16Vdc
22Vdc
55mA
60mA

Advertisement

loading
Need help?

Need help?

Do you have a question about the SRPL-2309iN-80CCT350-700H and is the answer not in the manual?

Questions and answers

Summary of Contents for Sunricher SRPL-2309iN-80CCT350-700H

  • Page 1 80W DALI D4i DT8 NFC LED Driver(Constant Current) Short Circuit Yes, recovers automatically after fault condition is removed Over Current Protection Yes, recovers automatically after fault condition is removed Over Temperature Yes, recovers automatically after temperature drop Important: Read All Instructions Prior to Installation -25℃...
  • Page 2: Operation

    Operation Step 3: Unlock device, enter parameters configuring page. With DALI master Locked Unlock it 1. DALI Address 1 DALI address for 2 channels output is assigned by DALI Master controller automatically, please refer to user manuals of compatible DALI Masters for specific operations. With NFC Programming devices Note 1) Do wiring according to the wiring diagram and power on the DALI system .
  • Page 3: Additional Remarks

    2.Enter CLO Setting homepage Step 5: After setting, please save the selected configuration via NFC and power on the device. Tips Enable CLO function Click “1",and set its time and level Set your desired time and levels. 1. NFC function doesn’t require any power driver. Graphic display 2.
  • Page 4 Wiring Diagram Safety & Warnings • DO NOT install with power applied to the device. 1. As a D4i Driver • DO NOT expose the device to moisture. DALI-2 Sensor Product Dimension Without End Cap ACN/ DALI DIMMABLE DRIVER ACL/ PUSH DIM 274.3 Note: Available with 4-Wire CCT LED luminaries as well.
  • Page 5 SRPL-2305iN-80CC350-700H 42 °C 53 °C 60 °C 90 °C(max) Note: Test data under SRPL-2309iN-80CCT350-700H 350 – 700 mA Lifetime > 100,000 h > 100,000 h > 30,000 h > 80,000 h 350mA gear The LED driver is designed for a lifetime stated above under reference conditions.
  • Page 6 Note: I ( A) 1.Those MCB parameters are based on ABB S200 series circuit breakers. peak 2.For different brands and models of miniature circuit breakers, the quantity of drivers will have difference. 3.Please do not exceed the above-mentioned quantity during on-site ½...