Page 1
cument Name User Manual Document N TG-TGSENSE E-001 eragun SEN Model er Ma anual Name Date Prepared dby: Ice Zh heng Reviewe edby: FelixC Chen Approve eby: CJ Fr rederick Revision H History Change e description Modified by Modifica ation date Initial rele ease.
Attachments ..........................11 Accessories ..........................12 Getting started ........................... 12 Using theTheragun SENSE ....................13 Connecting the attachments ....................13 Charging the Theragun SENSE ..................14 Cleaning Instructions ..........................15 Trouble Shooting ............................. 15 Problem ................................15 Solution ................................15 Device turns off automatically ........................
1. Recommendation of Use Device name :Theragun SENSE model :Theragun SENSE Read the full Warnings and Guidance prior to using the Theragun SENSE. -Provide a guided and non-guided in-dept massage therapy (percussion therapy) around the body to increase blood blow, reduce tension and knots, enhance pre and post workout routines leading to a faster recovery.
Page 4
· Pacemaker, ICD, or history of embolism For a full list of contraindications and additional warnings, please visit www.therabody.com. Patents & Pending Patents at www.therabody.com. Used to identify symptoms or medical conditions for apersonto not receive aparticular treat mentor procedure be cause it may be harmful.
SENSEon your head or near your genitals. Do not use Theragun SENSEabove the waist during pregnancy. Do not get hair caught in any moving part of the Theragun SENSE. Do not use tTheragun SENSE above your Adam’s Apple or C4.
Page 6
SENSE to the charger for more than an hour after the Theragun SENSE has been fully charged. The Theragun SENSE includes a protection system to avoid the risk of overcharging, however, overcharging the Theragun SENSE may reduce its life over time.
Page 7
17. DO NOT USE WHILE BATHING OR IN THE SHOWER, TUB, OR SINK. Do not place or store the Theragun SENSE where it can fall or be pulled into a tub or sink. Do not place in or drop into water or other liquid. Do not reach for an appliance that has fallen into water.
UserManu TG-TGSEN NSE-001 DocumentNam Documen ntNo. heragun SE ENSE Model THERMA AL LIMITER R. The The eragun SE ENSE emp ploys an a utomatic re eset ther rmal limite r that shut s off the T Theragun S SENSE to prevent ov verheating fire.
UserManu TG-TGSEN NSE-001 DocumentNam Documen ntNo. heragun SE ENSE Model Type BF a pply part Manufacture r information UKCA Mark for UK IntendedU Use&Indic cationsforU -Pro ovide a g guided and d non-guid ded in-dep pt massag ge therapy y (percuss sion ther rapy) arou...
DocumentName UserManual DocumentNo. TG-TGSENSE-001 Theragun SENSE Model 3. DeviceDescription Device Certification display in Screen guide as below : Information about your device's certification can be found in your device's settings. To Page 10 of 27...
3.1 Smart Features Theragun SENSE is smart device enabled with Bluetooth connectivity, designed to pair seamlessly with the Therabody app. When you download the app, you’ll be guided through a step-by-step setup and shown how to pair your device. Once paired with your device, the app can remotely adjust speed, activate guided treatment presets, and make real-time recommendations based on your feedback and recent activity.
3.4 Getting started Step 1 Turn on and float Firmly press and hold the center button on the button pad, then float the Theragun SENSE across areas in need. Use the up ( ) and down (v) buttons on Λ...
3.5 Using theTheragun SENSE 1) To turn on the Theragun SENSE, firmly press and hold the center button on the button pad. 2) Press the up ( ) and down (v) arrows to toggle between 5 preset speeds and Λ...
1 finger on each side of the plastic connector. Pull off the attachment. 3.7 Charging the Theragun SENSE 1) Your device includes a USB-C to USB-C SENSE USB-A cable so you can use a widervariety of adapters. The 3 circular LEDlights on the control panel of...
DocumentName UserManual DocumentNo. TG-TGSENSE-001 Theragun SENSE Model 4. Cleaning Instructions For the most hygienic Theragun device experience, sanitize it after each use by: 1) Wiping the device with a disinfectant wipe to remove any residue. 2) Once the device is residue-free, use a new wipe to disinfect the surface area by wiping all sides in a downward motion.
DocumentName UserManual DocumentNo. TG-TGSENSE-001 Theragun SENSE Model 6. Service Operation Instruction has no parts you can fix. Do not try to repair it. Ifservicing is required, please contact the selling retailer. All returned units to the manufacturer for repair, including Warranty repair and Out-Of-Warranty repair, must include the following: During Warranty Period with proof of Purchase (store receipt).
DocumentName UserManual DocumentNo. TG-TGSENSE-001 Theragun SENSE Model Environment for Temperature: -10° C ~ 50° C storage Relative humidity: 10~95% RH Use atmospheric 70-106Kpa pressure Software version V1.0 8. Safety, EMCRF This device is Class II equipment with type BF applied. It complies with Medical Electrical Safety Standards (IEC 60601-1).
Page 18
DocumentName UserManual DocumentNo. TG-TGSENSE-001 Theragun SENSE Model peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the ME EQUIPMENT, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment couldresult.”...
Page 19
DocumentName UserManual DocumentNo. TG-TGSENSE-001 Theragun SENSE Model Le présent appareil est conforme aux CNR d' Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil nedoit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,...
Page 20
DocumentName UserManual DocumentNo. TG-TGSENSE-001 Theragun SENSE Model Table1 declaration-electromagn eticemission Emissions test Compliance RFemissions Group1 CISPR11 RFemissions ClassB CISPR11 Harmonic emissions Not applicable IEC61000-3-2 Voltage fluctuations/ Not applicable flick eremissions IEC61000-3-3 Page 20 of 27...
Page 21
UserManu TG-TGSEN NSE-001 DocumentNam Documen ntNo. heragun SE ENSE Model Table declarat tion-electrom magnetic im munity mmunitytest IEC6 60601testlev mpliancelev Electrostatic ±8kVc contact ±8k kVcontact discharge ±2kV,± ±4kV,±8kV,± ±15 ±2k kV,±4kV,±8k kV,±15kVair ESD) kVair EC61000-4- ±2kVfo orpower Electricalfast tapplicable supply ylines ansient/burst ±1kVfo...
Page 22
DocumentName UserManual DocumentNo. TG-TGSENSE-001 Theragun SENSE Model IEC61000-4-8 NOTE:UT is the a.c. mains voltage prior to application of the test level. Table3 declaration-electromagnetic immunity Immunitytest IEC60601test Compliancelevel level Conducted Notapplicable 0.15MHzto80M IEC61000-4- 6VinISMbandsbet ween0.15MHzan d80MHz RadiatedRF 10V/m 10V/m IEC61000-4- 80MHzto2.7...
Page 23
DocumentName UserManual DocumentNo. TG-TGSENSE-001 Theragun SENSE Model Table4 declaration-IMMUNITY to proximity fields from RF wireless communication sequipment Immunity IEC60601testlevel Compliancelevel test Test Modulation Maximum Immunity frequency level power Radiated 385MHz **Pulse 1.8W 27V/m 27V/m Modulation: 18Hz 450MHz 28V/m 28V/m 61000-4-...
Note**-The c carrier shall b be modulate ed using a 50 0% duty cycl les quare wa ave signal. Manufact turer Infor mation Therabody y,Inc. 6100 Wilsh hire Blvd., Suite 200 0 Los Ange eles 90048-5 5107, LIMITED W WARRAN...
Page 25
DocumentName UserManual DocumentNo. TG-TGSENSE-001 Theragun SENSE Model The E-label information A. Access to the required information on the e-label 1. Users are able to access the information in no more than three steps in a device’ s menu. The actual steps are: To access the e-label information, in the device, Choose: Settings >Device...
Page 26
DocumentName UserManual DocumentNo. TG-TGSENSE-001 Theragun SENSE Model The e-label will display Regulatory information Page 26 of 27...
Page 27
DocumentName UserManual DocumentNo. TG-TGSENSE-001 Theragun SENSE Model B. Labeling for lmportation and Purchasing 1. Products utilizing e-labels are required to have a physical label on the product at the time of1.importation, marketing and sales. For devices imported in bulk and not packaged individually, a removable adhesive label or, for devices in protective bags, a label on the bags isacceptable for this purpose.