Page 2
Parts, product repairs, and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling.
Page 3
Table of Contents Title Page Introduction ........................1 How to Contact Fluke ..................... 1 Safety Information ......................2 Electromagnetic Compatibility (EMC) ................ 3 FCC Statement (U.S.A Only) ..................3 Laser Classification ....................4 Integrated Distance Meter ..................4 Laser Class 2 Products ..................4 Features .........................
Page 5
List of Tables Table Title Page Symbols ..........................2 Model Feature Comparison ....................5 Units of Measurement ......................11 Estimated Values of Magnetic Field ..................15 Message Codes ........................30 Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 7
Laser Distance Meter How to Contact Fluke Introduction To contact Fluke, call one of the following telephone The Fluke 414D/419D/424D Laser Distance Meters numbers: (Meter or Product) are professional-grade laser distance meters. Use these Meters to quickly and accurately get •...
Page 8
• Replace the batteries when the low battery Do not dispose of this product as unsorted indicator shows to prevent incorrect municipal waste. Go to Fluke's website for measurements. recycling information. • Do not use the Product around explosive gas.
Page 9
Changes or modifications not expressly This equipment has been tested and found to comply with approved by Fluke for compliance could void the limits for a Class B digital device, pursuant to part 15 the user’s authority to operate the of the FCC Rules.
Page 10
Looking into the laser beam may be hazardous to the eyes. Do not look into the laser beam. Make sure the laser is pointed above or below eye level, particularly with fixed installations in machines and similar setups. gwo20.gif Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 11
Stake Out Height Tracking • • • Multifunction Endpiece Room Corner Angle • • • • • Beeper Handstrap 419D and 424D store a maximum of 20 complete display readouts. 419D uses 1 value. 424D uses 2 values. Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 12
Attach the handstrap. Install two AAA (LR03) batteries with the correct polarity. Note Do not use zinc-carbon batteries. Close the battery compartment. W Caution To prevent corrosion, remove the batteries before a long period of nonuse. gwo01.eps Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 13
(90 °) until it locks into place. Push the endpiece lightly to the right side to fold it out fully. See Figures 3 and 5. • A built-in sensor automatically senses the orientation of the endpiece and adjusts the zero point. gwo03.eps gwo02.eps gwo04.eps Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 14
Plus (+)/Minus (-) Reference/Change Units Memory Compass Plus (+)/Scroll Up Area/Volume/Indirect Measurement (Pythagoras) Timer Minus (-)/Scroll Down Indirect Measurement (Pythagoras and Stake Out) Tilt Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 17
0 in 1/16 0.00 m • 3x = Leveling 0.00 ft * Default Push 1/32 0′00″ • 1x = Room Corner Angle (Triangular Area) 0.000 in • 2 seconds = 2 Results 1/32 0 in * Default Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 18
414D/419D/424D Users Manual Timer (419D/424D) Beeper (419D/424D) Fluke recommends that you use a time-delay for the most Push at the same time for 2 seconds to turn on accurate measurements at long distances. This prevents and turn off the beeper. The display shows the status as ...
Page 19
• 2 seconds = Arrow points in direction of Laser beam and display shows the direction in degrees and an alpha symbol. W Caution To prevent incorrect direction readouts, do not use near magnets and magnetic devices. Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 20
1. Push at the same time. The display shows and the current setting. The gwo22.eps default value is 0 °. 2. Push to change the value. 3. Push to accept the new value. Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 21
Chili Santiago de Chile Russia Irkutsk Denver China Beijing Russia Moscow Honolulu Egypt Cairo Russia Omsk Los Angeles France Paris Senegal Dakar Miami Germany Berlin Singapore Singapore New York Greece Athens South Africa Cape Town Venezuela Caracas Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 22
1x to change the reference point between the front and the end of the Meter. The display shows 419D/424D The Meter automatically adjusts the reference point when you use the endpiece and shows on the display. Auto-detect gwo07.eps Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 23
The last (maximum value) and the horizontal distance (minimum measured value shows in the summary line. value) from a stable measurement point. It also can find the distance between objects. See Figure 10. Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 24
The result shows in the summary line. line. Push to cancel the last step. Push and hold for 2 seconds to get the 2 result as a circumference. Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 25
(for example, depth). Push x 2 seconds to show additional room The result displays in the summary line. information such as ceiling/floor area, surface area of the walls, circumference. Ceiling/floor area (424D) Wall area (419/424) Circumference (419D/424D) Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 26
Move the laser upwards to the top target. Height Tracking starts automatically. The display shows the Push to turn off Smart Horizontal Mode. angle to the actual target and the vertical distance from the lower target. Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 27
90 ° angle measurements. See page 17 for more information. Push 3x = Leveling. shows in the display. Put the Meter on object to do a test for level. The angle continuously shows on the display as the object moves. gwo10.eps Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 28
Turn the upright Meter 180 ° on the same flat surface. Push 180° The display shows the calibration results as . gwo23.eps Put the Meter on a flat horizontal surface. Push The display shows the instructions for the subsequent measurement. Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 29
0.1 m (4 in) from the next stake out point. As the Meter moves near to the stake out point, the beep changes and the arrows do not show on the display. Push to stop the stake out function. Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 30
(b) value. Push to accept the (b) value. The display shows the stake out distance in the summary line between the stake out point (a and then b) and the Meter (rear reference). Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 31
(d3). Push for 2 seconds to get the second results as The result shows in the summary line as the room the angle between d1 and d2, the triangle triangle area. circumference, and the area. Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 32
Make sure that the Meter is perpendicular to the wall. Push for the second distance measurement. The Meter shows the height in the summary line. The distance of the second measurement shows in the secondary line. Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 33
The third measurement shows in the Move the laser side to side and up and down on the secondary line. ideal horizontal target point. Push to stop the tracking mode. Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 34
. The Meter stores this measurement value. Make sure that the Meter is perpendicular to the wall. Point the laser at the second diagonal target (2). Push for the second distance. Push for the second distance measurement. Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 35
If damaged, do not use and disable the Meter. To disable, maximum of 20 displays. remove the batteries. See page 6 for more information. To recall: Push Push to move through the stored displays. Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 36
Hold the Meter without a transverse tilt. Calibration mistake Make sure that the device is on a horizontal and flat surface. Do the calibration procedure again. If the code continues, contact Fluke. Calculation error Do the measurement again. Temperature too high Let the Meter cool down.
Page 37
0.24 in @ 33 ft / 1.2 in @ 164 ft / 2.4 in @ 328 ft Tilt measurement Measurement tolerance to laser beam ± 0.2 ° Measurement tolerance to case ± 0.2 ° Range 360 ° Compass accuracy 8 points (± 22.5 °) Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 38
(-13 °F to +158 °F) Operation 0 °C to +40 °C -10 °C to +50 °C (32 °F to +104 °F) (14 °F to +122 °F) Calibration cycle Not applicable Not applicable Tilt and Compass Maximum altitude 3500 m Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Page 39
[5] After user calibration. Additional angle related deviation of ±0.01 per degree up to ±45 in each quadrant. Applies at room temperature. For the whole ° operating temperature range the maximum deviation increases by ±0.1 [6] After calibration. Do not use the compass for navigation. Fluke-Direct info@Fluke-Direct.ca 1.800.868.7495...
Need help?
Do you have a question about the 414D/62 MAX+ and is the answer not in the manual?
Questions and answers