Military sales: ksilver@aqualung.com Trademark Notice Aqua Lung , is a registered trademark of Aqua Lung America, Inc. ® Warnings, Cautions, & Notes Pay special attention to information provided in warnings, cautions and notes that are accompanied by one of these symbols:...
This manual provides factory prescribed procedures for the correct Unless otherwise instructed, the following terminology and techniques service and repair of the Aqua Lung SEA MK. It is not intended to be used are assumed: as an instructional manual for untrained personnel.
SEA MK Technical Maintenance Manual Initial Inspection procedure Medium (over-Bottom) pressure Test External Inspection 1. With the valve closed, purge the second stage to depres- surize the system. While securely holding the second 1. When possible, inspect the filter of the fill adapter for stage inlet fitting (51) with a thin 3/4"...
DISASSEMBLy pRoCEDURE 5. Unscrew and discard the burst plug (6) from the first stage (36) using a 3/8" socket. NOTE: Before performing any disassembly, refer to the exploded parts drawing, which references all mandatory replacement parts. These parts should be replaced with new and must not be reused under any circumstances –...
Page 8
SEA MK Technical Maintenance Manual 10. Insert the squared end of the stem into the valve seat b. Using a 1/8" hex key unscrew the retaining screw (27g) (20) and unscrew and discard the valve seat from the first from the pin indicator body (27b). Remove the spring (27e) stage body.
17. Remove and discard the fill adapter port o-ring (22). 22. Using the bottle vice (pn 100397), vice insert (pn 100398) or strap wrench (pn 54325A22), hold the cylinder secure. While holding the cylinder secure, unscrew the first stage body (36) from the cylinder using a 1 3/16"...
Page 10
SEA MK Technical Maintenance Manual 3. Lift out the thrust washer (42) and diaphragm (43). Inspect the 7. Remove and discard the exhaust valve (56) by grasping the diaphragm for any tears or pin holes by holding it up to a light and flap of each valve and pulling straight outward.
REASSEMBLy pRoCEDURE 4. Place the spring (35) into the body. Press the piston into the cap (30) so that the piston head is seated flat against the cap. Verify there is no dirt or damage to the smooth inner sides First Stage Reassembly of the cap.
Page 12
SEA MK Technical Maintenance Manual 9. SEA MK with a pin-type pressure indicator (27a): 10. SEA MK with a dial-type pressure indicator (27): a. Install a new o-ring (22) onto the dial pressure indicator a. Drop a new lubricated o-ring (27c) into the pin indicator (27).
Page 13
14. Place a new, lubricated white washer (18) onto the valve 17. Attach a 3/4" crowfoot or medium deep-well socket to a stem (19), followed by the metal spacer (17) and lubricated torque wrench and tighten the bonnet to 90±3 in/lbs. o-ring (16).
SEA MK Technical Maintenance Manual Second Stage Reassembly 1. Install a new exhaust valves (56) by inserting the stem of the exhaust valve through the center hole of the exhaust port. Pull the stem all the way through until the mushroom plug pops through the hole and keeps the valve securely in place.
5. Install a new inlet fitting o-ring (14) in the groove located 9. Place the washer (46) over the threads of the stem. Thread between the wrench flats and shorter threads. a new locknut (44) onto the stem. Using a 1/4" nutdriver, tighten the locknut until about two threads show past the locknut.
SEA MK Technical Maintenance Manual 13. Close the SEA on/off valve by turning the handwheel 18. Install the mouthpiece (58) onto the box bottom. Loosely clockwise. Purge the air from the system by pressing down fasten a tie-strap clamp (55) over the slots at the base of the on the lever.
Page 17
WARNING: The SEA MK is designed to assist heli- copter crew members and passengers in emergency egress situations from submerged aircraft. It is very critical to ensure that no leakage is present, and that the unit has met all requirements in the Final Testing procedures outlined above.
Page 18
SEA MK Technical Maintenance Manual Table 1: Troubleshooting guide First Stage/Valve Assembly SyMpToM poSSIBLE CAUSE TREATMENT 1. The valve seat (20) is worn or damaged. 1. Replace valve seat. Lp system will not remain depressurized after valve is shut and second stage is purged.
Page 19
6. Disassemble and replace o-ring. Note: This is a partial list of possible problems and recommended treatments. For more information, contact Aqua Lung Technical Service Department for as- sistance with problems not described here. CAUTION: Recommended treatments which require disassembly of the regulator must be performed during a complete overhaul, according to the prescribed procedures for scheduled, annual service.
Page 20
SEA MK Technical Maintenance Manual Table 3: List of Tools and Service Kits pART # DESCRIpTIoN AppLICATIoN IP Gauge 111610 Checking medium pressure 0-400 psi Soft Case, 108362 IP test gauge IP Test Gauge SCUBA Fill 108325 IP testing and filling Adapter 944022 O-ring Tool...
Page 21
Table 3: List of Tools and Service Kits (continued) pART # DESCRIpTIoN AppLICATIoN 108361 Tool Pouch Tool holder Hex Key Sockets 9-AM11708 Pin-type pressure indicator (27) and LP swivel port plug (1) (1/8", 3/16") 9-46661 Pliers, 9-45171 Mouthpiece clamp (55) small cutter Cylinder 9-47709...
Page 22
SEA MK Technical Maintenance Manual Table 3: List of Tools and Service Kits (continued) pART # DESCRIpTIoN AppLICATIoN Wrench 9-44388 (11/16" & Hose fitting (11/16") 9-44385 1/2”) 7/16” Wrench 9-44572 1/2” Wrench MRS III 9-44385 9-44592 9/16” Wrench Reversible snap 111100 MRS III ring pliers...
Page 23
Table 3: List of Tools and Service Kits MISCELLANEoUS TooLS pART # DESCRIpTIoN AppLICATIoN Torque Apply torque to parts listed in Wrench Table 4: Torque Specifications, p. 24 ft/lbs / in/lbs HABD/SEA 100397 SEA bottle removal & installation BOTTLE VICE HABD/SEA 100398 BOTTLE VICE...
Page 24
Purge Flow MP 135±20 psi 5.0 SCFM flow rate (minimum) Table 6: Recommended Cleaners and Lubricants LUBRICANT/CLEANER AppLICATIoN SoURCE Aqua Lung, PN 820466, or Lubrication Technologies Christo-Lube MCg 111 All o-rings 310 Morton Street Jackson, OH 45640 (800) 477-8704 CAUTION: Silicone rubber requires no lubrication or preservative treatment.
procedure A: Cleaning and Lubricating Cleaning Brass and Stainless Steel parts 1. Preclean in warm, soapy water* using a nylon bristle tooth brush. 2. Thoroughly clean parts in an ultrasonic cleaner filled with soapy water. If there are stubborn deposits, household white distilled vinegar (acetic acid) in an ultrasonic cleaner will work well.