Julabo 1000FF Original Operating Manual
Julabo 1000FF Original Operating Manual

Julabo 1000FF Original Operating Manual

Ultra-low refrigerated circulator

Advertisement

Quick Links

Pos : 3 /=== T ec hnis che D ok umentati on/=== M OD-Allgem ein [Ei nz elmodul e]/MOD-DBL --- [D eck blatt - D IN A5]/MOD-D BL_BA/M OD-DBL_BA_Käl tebad_1000FF _U S @ 11\m od_1719298918183_18.docx @ 75100 @ @ 1
Ultra-low refrigerated circulator
Original operating manual
30003224.A
08/2024
US
Pos : 4 /=== T ec hnis che D ok umentati on/=== M OD-Allgem ein [Ei nz elmodul e]/MOD-ST E --- [Steuermodule]/MOD-STE_### Seitenum bruc h ### @ 1\m od_1557390683938_0.doc x @ 16738 @ @ 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1000FF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Julabo 1000FF

  • Page 1 Pos : 3 /=== T ec hnis che D ok umentati on/=== M OD-Allgem ein [Ei nz elmodul e]/MOD-DBL --- [D eck blatt - D IN A5]/MOD-D BL_BA/M OD-DBL_BA_Käl tebad_1000FF _U S @ 11\m od_1719298918183_18.docx @ 75100 @ @ 1 Ultra-low refrigerated circulator Original operating manual 30003224.A...
  • Page 2 Pos : 5. 3 /=== T ec hnisc he D ok umentation/=== M OD-Allgem ein [Ei nz elmodul e]/M OD-BES --- [Besc hrei bung ohne Bil d]/ 99_Allgemei n/M OD-BES_Im press um-Adres se_002_U S @ 3\m od_1591173336056_18.docx @ 32310 @ @ 1 USA Office: JULABO USA, Inc. 884 Marcon Boulevard...
  • Page 3: Table Of Contents

    Pos : 7 /=== T ec hnis che D ok umentati on/=== M OD-Allgem ein [Ei nz elmodul e]/MOD-ST E --- [Steuermodule]/Inhaltsv erz eichnis _3Ebenen @ 1\m od_1553672359058_0.docx @ 14095 @ @ 1 Foreword ..................... 4 About this manual ................5 Notes on commissioning and operation .......... 5 Original JULABO spare parts ............5 Accessories ..................5 Warnings ..................6 Symbols used .................. 6 Intended use ..................
  • Page 4: Foreword

    Pos : 11 /=== T echnisc he Dokum entation/=== MOD- Allgemei n [Ei nzelm odul e]/M OD-EIN --- [Ei nführ ung i n ein T hema]/99_Allgem ein/MOD- EIN _Vorwort_001_Betriebs anl eitung @ 1\mod_1557396950819_18. docx @ 16945 @ @ 1 Congratulations! You have made an excellent choice. JULABO would like to thank you for the trust you have placed in our company and products. This operating manual will help you become acquainted with the use of our units.
  • Page 5: About This Manual

    Pos : 14.12.3 /=== T ec hnische D ok umentati on/=== MOD-Allgem ein [Einz elmodule]/MOD-BES --- [Besc hrei bung ohne Bild]/02_Besc hreiben/MOD- BES_Original JULABO Ersatzteile_001 @ 7\mod_1648195445571_18. docx @ 51990 @ @ 1 Only original JULABO spare parts guarantee the highest possible quality and safety.
  • Page 6: Warnings

    About this manual Warnings Pos : 14.16.2 /=== T ec hnische D ok ument ati on/=== MOD-Allgem ein [Einz elmodule]/MOD-EIN --- [Einführung in ei n T hem a]/01_Sic her heit/MOD- EIN _Allgem ein_AN SI-War nhinw eise_001 @ 1\mod_1557408322607_18.docx @ 17030 @ @ 1 The manual contains warnings to increase safety when using the device.
  • Page 7: Intended Use

    Pos : 16.5 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-BES --- [Beschr eibung ohne Bild]/01_Sic herheit/M OD-BES_Bestimm ungsgem äß e Verw endung _003_Kältem asc hine @ 11\m od_1723028687359_18.docx @ 75622 @ @ 1 This is a laboratory device intended for temperature control applications of liquid media. It can only be operated in conjunction with a JULABO circulator designed for this purpose.
  • Page 8: Safety

    Safety Safety Pos : 19.1 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-SE0 --- [Sektion, Übersc hriften]/MOD- SE2/01_Sicherheit /MOD-SE2_Allgemei ne Sic herheits hinw eise Betr eiber @ 1\m od_1557395775981_18.docx @ 16841 @ 2 @ 1 General Safety Instructions for the operating company Pos : 19.2 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-EIN --- [Ei nführ ung i n ein T hema]/01_Sic herheit/M OD-EIN _Allgem ei ne_Sic herheits hinw eise_Betreiber _001 @ 2\m od_1564996446926_18.docx @ 22776 @ @ 1 This section outlines the General Safety Instructions that must be observed by the operator to ensure safe operation.
  • Page 9: Safety Instructions

    Refrigerants and their vapors are harmful to health. There is a suffocation risk in enclosed spaces. • Do not touch or inhale refrigerants. • Have damage to the refrigerant cycle repaired only by JULABO service technicians or qualified specialists. • If refrigerant leaks, stop the device immediately and ventilate the room thoroughly.
  • Page 10 If refrigerant leaks, stop the device immediately and ventilate the room thoroughly. • Do not damage the refrigerant cycle. • Have damage to the refrigerant cycle repaired only by JULABO service technicians or qualified specialists. • Have maintenance work performed only by JULABO service technicians or qualified specialists.
  • Page 11: Safety Symbols

    • All other maintenance and repair work may only be carried out by a JULABO service technician or a qualified specialist workshop. Pos : 21.1 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-SE0 --- [Sektion, Übersc hriften]/MOD- SE2/ 01_Sicherheit/MOD-SE2_Sicherheits kennzeic hen @ 2\m od_1563872289124_18.docx @ 21917 @ 2 @ 1 Safety symbols Pos : 21.2 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-EIN --- [Ei nführ ung i n ein T hema]/01_Sic herheit/M OD-EIN _Si cherheitsk ennz eic hen_BA_001 @ 2\m od_1563872345668_18.docx @ 21930 @ @ 1...
  • Page 12: Safety Function

    Safety Locations of safety signs Pos : 23.1 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-SE0 --- [Sektion, Übersc hriften]/MOD- SE2/01_Sicherheit /MOD-SE2_Schutzei nrichtungen @ 2\mod_1563803850747_18.doc x @ 21790 @ 2 @ 1 Safety function Pos : 23.4 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-EIN --- [Ei nführ ung i n ein T hema]/01_Sic herheit/M OD-EIN _Schutz ei nrichtungen_allgemei n_003_Kältem aschi ne_BA @ 3\m od_1575276152030_18.docx @ 27164 @ @ 1 Technical safety functions protect the device from damage.
  • Page 13: Product Description

    Product description Product description Pos : 26 /=== T echnisc he Dokum entation/=== MOD- Allgemei n [Ei nzelm odul e]/M OD-SE0 --- [Sekti on, Übersc hriften]/MOD- SE2/ 02_Beschr eiben/MOD- SE2_Funkti onsbesc hrei bung @ 2\mod_1563803920851_18.doc x @ 21803 @ 2 @ 1 Function description Pos : 27 /=== T echnisc he Dokum entation/=== MOD- Allgemei n [Ei nzelm odul e]/M OD-EIN --- [Ei nführ ung i n ein T hema]/02_Besc hrei ben/MOD-EIN_F unkti ons besc hrei bung_001_Gerät @ 2\m od_1559031578490_18.docx @ 18632 @ @ 1 This section describes the function of the device.
  • Page 14: Operating And Functional Elements

    Product description Operating and functional elements Pos : 31.2 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-EIN --- [Ei nführ ung i n ein T hema]/02_Besc hrei ben/M OD-EIN_Bedi en- und Funkti onsel emente_001 @ 1\m od_1557152100508_18.docx @ 16178 @ @ 1 The following figure shows the operating and functional elements and their position on the unit.
  • Page 15: Technical Data

    Product description Technical data Pos : 33.2 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-EIN --- [Ei nführ ung i n ein T hema]/02_Besc hrei ben/M OD-EIN_T ec hnis che D aten_010_gemessen nach DIN 12876_001 @ 6\m od_1631772914624_18.docx @ 48800 @ @ 1 Performance specifications measured in accordance with DIN12876.
  • Page 16 Product description Technical data 1000FF Performance values Working temperature range °C -90 … 100 Refrigerant R290 / R170 Dimensions Dimensions (W x D x H) 55 x 60 x 94 Usuable bath opening (W x D) 13 x 15 Bath depth Volumes min.
  • Page 17: 5.3.1 Material Of Parts That Come Into Contact With The Medium

    Product description 5.3.1 Material of parts that come into contact with the medium Pos : 35 /=== T echnisc he Dokum entation/=== MOD- Allgemei n [Ei nzelm odul e]/M OD-EIN --- [Ei nführ ung i n ein T hema]/02_Besc hrei ben/MOD-EIN_M aterial der Medium berührenden T eile @ 2\m od_1564990884664_18.docx @ 22716 @ @ 1 The table lists parts that could come into contact with the bath fluid as well as the material that the parts are made of.
  • Page 18: Transport And Installation

    Transport and installation Transport and installation Pos : 44 /=== T echnisc he Dokum entation/=== MOD- Allgemei n [Ei nzelm odul e]/M OD-EIN --- [Ei nführ ung i n ein T hema]/03_Trans por tieren und Aufs tell en/MOD-EIN_Tr ansportier en und Aufstellen_001_Gerät @ 1\mod_1557487631691_18.doc x @ 17298 @ @ 1 This section describes how to transport the unit safely.
  • Page 19: Maintenance

    We recommend only using original JULABO spare parts. Pos : 53.1 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-SE0 --- [Sektion, Übersc hriften]/MOD- SE2/ 06_Ins tandhalten/MOD-SE2_Sicherheits kennzeic hen prüfen @ 4\m od_1599026293561_18.docx @ 34840 @ 2 @ 1...
  • Page 20: Check Safety Symbols

    Maintenance Check safety symbols Pos : 53.2 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-EIN --- [Ei nführ ung i n ein T hema]/06_Inst andhal ten/M OD-EIN _Sic herheitsk ennz eic hen prüfen_001_U SA_CDA @ 4\m od_1599026570432_18.docx @ 34854 @ @ 1 The following section applies only to equipment working with natural refrigerants and operated in the US or Canada.
  • Page 21 1. Check the safety symbols on the unit for legibility and completeness. 2. Replace defective or missing safety symbols.  Safety symbols can be reordered from JULABO.  The safety symbols on the unit have been checked. Pos : 55.1 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-SE0 --- [Sektion, Übersc hriften]/MOD- SE2/ 04_Inbetriebnehm en/MOD- SE2_Gerät entl eer en @ 2\mod_1557752797112_18.docx @ 17584 @ 2 @ 1...
  • Page 22: Emptying

    Maintenance Emptying Pos : 55.2 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-EIN --- [Ei nführ ung i n ein T hema]/06_Inst andhal ten/M OD-EIN _G erät entleeren_001 @ 2\m od_1557753345282_18.docx @ 17621 @ @ 1 The device must be completely drained if it is to be sent in for technical service or is to be properly disposed of.
  • Page 23: Clean Device

    Maintenance Clean device Pos : 56.2 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-EIN --- [Ei nführ ung i n ein T hema]/06_Instandhal ten/M OD-EIN _Gerät rei nigen_001_allgemei n @ 3\mod_1590475318423_18.doc x @ 31826 @ @ 1 The outside of the device should be periodically cleaned.
  • Page 24: Cleaning Condenser

    Maintenance Cleaning condenser Pos : 57.2 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-EIN --- [Ei nführ ung i n ein T hema]/06_Inst andhal ten/M OD-EIN _Verfl üssiger r einigen_001 @ 2\m od_1575271276671_18.docx @ 27080 @ @ 1 From time to time, the condenser on the front of the device should be cleaned to maintain full cooling capacity.
  • Page 25: Device Storage

    Pos : 60.4 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-BES --- [Beschr eibung ohne Bild]/06_Instandhal ten/M OD-BES_Technisc her Service_002_U S_bis _12_2020_[BA] @ 3\mod_1591173708485_18.docx @ 32322 @ @ 1 JULABO Technical Service Tel.: +1(610) 231-0250 Option 3 Fax: +1(610) 231-260 Email: Service@julabo.us...
  • Page 26: Warranty

    The following Warranty Provisions shall apply to products sold in North America by Julabo (“Seller”) to the entity shown as buyer (“Buyer”) on Seller’s invoice. Pos : 61.6 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-BES --- [Beschr eibung ohne Bild]/06_Inst andhal ten/M OD-BES_Gewährleis tung_002_US @ 3\m od_1591261685250_18.docx @ 32475 @ @ 1 Initial Warranty Upon Seller’s receipt of payment in full for the products and subject to Buyer’s...
  • Page 27 Maintenance Buyer’s sole remedies; Limitations on Seller’s Liability Buyer’s sole and exclusive remedy under the Initial Warranty is strictly limited, in Seller’s sole discretion, to either: (i) repairing defective parts; or (ii) replacing defective parts. In either case, the warranty period for the product receiving a repaired or replaced part pursuant to the terms of the Initial Warranty shall not be extended.
  • Page 28: Governing Law

    The same exclusions that apply to the regular warranty also apply to OBF classification. For example, JULABO will not be liable for transport damage, damage inflicted by the customer or any other party, or defects arising from improper installation or usage.
  • Page 29: Disposal

    Disposal Disposal Pos : 63.2 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-SE0 --- [Sektion, Übersc hriften]/MOD- SE2/ 07_Entsorgen/M OD-SE2_Ger ät ents orgen @ 2\m od_1563803242558_18.docx @ 21712 @ 2 @ 1 Device disposal Pos : 63.3 /=== Technisc he Dokum entation/=== MOD- Allgemei n [Einzelm odule]/M OD-EIN --- [Ei nführ ung i n ein T hema]/07_Ents orgen/M OD-EIN _Gerät entsorgen_001 @ 2\mod_1557752344596_18.doc x @ 17560 @ @ 1 When disposing of the device, the applicable country-specific guidelines must be observed.