Meteor Floodlights
Product Codes: MET10-60, MET20-60, MET30-60, MET50-60,
MET100-60, MET150-60, MET200-60
Safety Warning
•
The installation should be carried out
by a qualified electrician in compliance
with the current edition of the IEE
Wiring Regulations.
•
Prior to installation, carry out the
necessary risk assessment considering
the people who could be at risk,
the level of risk and the precautions
required to control the risk
•
Ensure that the circuit supply is
isolated either by the circuit supply
fuse being removed or the applicable
Specification
Box Contents -
1 x Meteor Floodlight
MET10-60: L: 95 x W: 120 x D: 15mm
MET20-60: L: 105 x W: 140 x D: 19mm
MET30-60: L: 145 x W: 177 x D: 19mm
Dimensions:
MET50-60: L: 193 x W: 223 x D: 19mm
MET100-60: L: 242 x W: 291 x D: 19mm
MET150-60: L: 305 x W: 353 x D: 24mm
MET200-60: L: 336 x W: 403 x D: 25mm
Material:
Body - Die-cast Aluminium, Lens - Polycarbonate
Working
Standard: -20°C - 45°C
Temperature:
1m Pre-wired Cable
Included:
Steel Mounting Bracket
10-
180-
LED
100
240V
WATT
Maximum Fittings Per Circuit
Automatic Circuit Breaker Type:
B6
Rated Current:
6A
Cable (mm):
1.5
MET10-60
150
MET20-60
75
MET30-60
60
MET50-60
30
MET100-60
15
MET150-60
10
MET200-60
7
Installation Instructions
1.
Ensure there is adequate free air circulation of at least 100mm around the fitting. All fittings run hot. It is the installer's responsibility to consider any fire
risk and take appropriate precautions.
2.
The nearest illuminated surface must be at least 0.5m from the front of the fitting.
3.
Check for concealed cables before drilling any fixing holes.
4.
Fix the bracket to a wall or similar hard surface.
5.
Connect the cable to the power supply.
PAGE 1 ( FRONT PAGE )
INSTALLATION INSTRUCTIONS
circuit breaker being turned off before
installation or any maintenance.
•
Check the total load on the circuit
ensuring the luminaire does not exceed
the rating of the circuit cable, fuse or
circuit breaker.
•
Long-term use and voltage fluctuations
can reduce the life span of the fitting.
•
If the fitting incorporates control gear,
ensure careful sizing to avoid instances
of nuisance tripping of the protective
device used in the installation.
IP65
6000K
B10
B13
B16
B20
C10
C13
10A
13A
16A
20A
10A
13A
1.5
1.5
1.5
2.5
1.5
1.5
250
325
400
500
250
325
125
163
200
250
125
163
100
130
160
200
100
130
50
65
80
100
50
65
25
32
40
50
25
32
17
22
26
33
17
22
11
14
18
22
11
14
•
•
Wmm
900-
IK07
19,600LM
C16
C20
16A
20A
1.5
2.5
400
500
200
250
160
200
80
100
40
50
26
33
18
22
Follow the provided installation
instructions, using the fixings supplied
or recommended.
Keep out of reach of children.
Dmm
2
YRS
GUARANTEE
Need help?