  • Page 1 FENCE ENERGIZER i SERIES Instructions - ENG...
  • Page 2 3E3618 - Edi on 12 - August 2022 DISCLAIMER: Whilst every eff ort has been made to ensure accuracy, neither Gallagher Group Limited nor any employee of the company shall be liable on any ground whatsoever to any party in respect of decisions or ac ons they may make as a result of using this informa on.
  • Page 3: Table Of Contents

    Contents 3E3446 M5800i Energizer User Manual Important Informa on ....................... 5 How the Energizer works ......................8 Installa on Guide ........................9 Understanding Your Energizer ....................12 Understanding Your Energizer Controller ................13 Accessories ..........................19 Troubleshoo ng ........................20 Waste Electrical And Electronic Equipment ................
  • Page 5: Important Informa On

    • Regularly inspect the supply cord, cables, wires and energizer for any damage. If found damaged in any way, immediately cease use of the energizer and return it to a Gallagher Authorised Service Centre for repair in order to avoid a hazard.
  • Page 6 Important Informa on ver cal plane of the non-electrifi ed wires. The barbed wire and razor wire shall be earthed at regular intervals. • Follow the energizer manufacturer’s recommenda ons regarding earthing. • The energizer earth electrode should penetrate the ground to a depth of at least 1 m (3 ) and not be within 10 m (33 ) of any power, telecommunica ons or other system.
  • Page 7 This energizer complies with interna onal safety regula ons and is manufactured to interna onal standards. Gallagher reserves the right to make changes without no ce to any product specifi ca on to improve reliability, func on or design. E & OE.
  • Page 8: How The Energizer Works

    Gallagher 3E3618 i Series Energizer User Manual HOW THE ENERGIZER WORKS The energizer sends electrical pulses along the fence line, about one second apart. These pulses give the animal a short, sharp, but safe shock. The shock doesn’t harm the animal. It is suffi ciently memorable that the animal never forgets the shock, and will avoid the fence.
  • Page 9: Installa On Guide

    Gallagher 3E3618 i Series Energizer User Manual INSTALLATION GUIDE Energizer Controller Mount the controller on a fl at surface within 3m (10 ) of the energizer, or up to 50m (160 ) if using an RJ-12 extension cable*. The controller is suitable for indoor and outdoor use.
  • Page 10 Earth Stake (G879) and then clamp the exposed wire to each stake using an Earth Clamp (G876). Tighten the clamp. For further instruc ons on the earth (ground) system see the Gallagher Power Fence™ Manual. Note: Poor grounding can cause interference on telephone lines, radios and televisions.
  • Page 11 Screw the terminal closed, ensuring the wire is fi rmly clamped. A ach the other end of the cable to the fence using a Joint Clamp (G603). For instruc ons on fence installa on see the Gallagher Power Fence™ Manual or go to www.gallagher.com.
  • Page 12: Understanding Your Energizer

    Gallagher 3E3618 i Series Energizer User Manual UNDERSTANDING YOUR ENERGIZER Fence Fault LED Power On LED Flashing red when the Green when the energizer has detected a energizer is powered fence fault. Solid red when there is a sudden increase in fence load.
  • Page 13: Understanding Your Energizer Controller

    Gallagher 3E3618 i Series Energizer User Manual UNDERSTANDING YOUR ENERGIZER CONTROLLER Voltage Display Current Display Shows energizer / earth / fence zones voltage Shows the amount of load on the energizer / fence zones Status LED Quickscan Bargraph Provides quick...
  • Page 14: Current Display

    Gallagher 3E3618 i Series Energizer User Manual Current Display The output current indicates how hard your energizer is working. When your fence is in good condi on this reading will be low, typically under 15 Amps. As the load on the fence increases the current will rise and output voltage will fall. The output current will typically change with fence condi ons, seasonal grass growth and wet weather.
  • Page 15: Using The Energizer Controller

    Gallagher 3E3618 i Series Energizer User Manual Using The Energizer Controller Energizer Output and Alarms The energizer output is the default screen display mode. The zone indicator arrow is highligh ng the energizer zone ( ) and the energizer output voltage is 7.3KV in this case.
  • Page 16: Current Alarm

    fi nd faults before your fence becomes ineff ec ve (voltage too low), Gallagher recommend se ng the current alarm 10A above normal opera on. Many events can cause the current to increase, including rainfall, grass growth, broken fences and failed insulators.
  • Page 17: Quick Reference

    0.2-0.3KV is achieved. In dry condi ons or areas with low mineral content soil an earth return system may be required as described in the Gallagher Power Fence™ Manual or visit www.gallagher.com.
  • Page 18 Gallagher 3E3618 i Series Energizer User Manual Fence Zone 1–6 View the Fence Zone performances by pressing the naviga on bu ons (< or >) un l the zone indica on arrow is highligh ng the desired fence zone (1–6). The fence zones voltage, current and alarm informa on is displayed in the same way as the Energizer output informa on.
  • Page 19: Accessories

    Controller indica ng that zone is below the set alarm voltage. Gallagher Energizer Remote and Fault Finder G50700 The Gallagher Energizer Remote and Fault Finder displays which zone(s) are in fault and can then be used to locate the fault within that zone. Power to the fence at the fault loca on can be turned off...
  • Page 20: Troubleshooting

    Gallagher 3E3618 i Series Energizer User Manual TROUBLESHOOTING Problem Causes Solution Energizer has started to run The internal temperature of Mount the energizer in a cool slowly the energizer is too high area, out of direct sun and with adequate ven la on.
  • Page 21 ENERGIZER REMOTE & FAULT FINDER...
  • Page 22: 3E2749 Remote & Fault Finder User Manual

    Contents 3E2749 Remote & Fault Finder User Manual Remote Readings ........................23 Installing the ba ery ........................ 24 Features ........................... 24 Checking your fence and fi nding faults ..................25 Detec ng Alarms ........................26 Turning the Energizer On / Off (Standby) ................26 Using your Remote with mul ple Energizers ................
  • Page 23: Remote Readings

    Gallagher 3E3618 i Series Energizer User Manual REMOTE READINGS Liquid Crystal Display This is the full range of symbols. The meaning of each symbol is detailed below. 1 2 3 4 5 6 Standby Indicates the energizer is in Standby mode .
  • Page 24: Installing The Ba Ery

    The remote ba ery has a life of approximately 6 months. A fl at ba ery may give false measurements so replace the ba ery when the icon shows. FEATURES The Gallagher Energizer Remote and Fault Finder enables you to do the following: • Measure fence voltage and current •...
  • Page 25: Checking Your Fence And Finding Faults

    Gallagher 3E3618 i Series Energizer User Manual CHECKING YOUR FENCE AND FINDING FAULTS Place the fence wire in the fence connec ons slot while holding the remote as shown below. IMPORTANT Always grip your i-Series Remote fi rmly, with your fi ngers in contact with the ba ery cover, to avoid a mild fence shock.
  • Page 26: Detec Ng Alarms

    Gallagher 3E3618 i Series Energizer User Manual DETECTING ALARMS You can communicate with the devices opera ng on your fence by pressing the bu on. System status is “OK” No alarms Energizer status Not in alarm Connected fence zones - None are in alarm System status is “AL”...
  • Page 27: Using Your Remote With Mul Ple Energizers

    Gallagher 3E3618 i Series Energizer User Manual USING YOUR REMOTE WITH MULTIPLE ENERGIZERS The Remote has nine channels that can be “tuned in” to a specifi c energizer, enabling the Remote to control up to nine energizers. Note: You do NOT need to register your Remote with the Energizer if you are only using one Energizer.
  • Page 28 Gallagher 3E3618 i Series Energizer User Manual Use this table to record which channel number is set to each energizer. Channel Energizer...
  • Page 29: Understanding Your Electric Fence

    Gallagher 3E3618 i Series Energizer User Manual UNDERSTANDING YOUR ELECTRIC FENCE Compare your electric fence to a water supply system. Fence Voltage = Water Pressure Electric Current = Water Volume/Flow A perfectly performing Electric fence is similar to a water system that has a pressure pump (Energizer) at one end and a bung at the other.
  • Page 31 FENCE MONITOR...
  • Page 32: 3E2748 Fence Monitor User Manual

    Contents 3E2748 Fence Monitor User Manual Introduc on ..........................33 Installa on ..........................34 Using your Fence Monitor ....................... 37 Choosing an Installa on Loca on .................... 39 Troubleshoo ng ........................42...
  • Page 33: Introduc On

    2 moun ng screws • Stock protec on wire • 2 cable es • Ba ery holder • 6 AA alkaline ba eries Note: Earth stake is not included. It is recommended you use a Gallagher G87800 earth stake or similar.
  • Page 34: Installa On

    Gallagher 3E3618 i Series Energizer User Manual INSTALLATION For how to set up fence zones on your farm, see Choosing an Installa on Loca on (p. Step 1: Remove the cover and the ba ery holder. Step 2: Mount the unit to a post in either of the following ways:...
  • Page 35 Gallagher 3E3618 i Series Energizer User Manual Step 3: Connect to the fence, energizer and earth stake. Status LED To fence To fence To earth/ground The stock protec on wire can be a ached to either side of the Fence Monitor (the side most accessible to stock), by placing it under the bolt on one of the Output terminals ( ).
  • Page 36 Gallagher 3E3618 i Series Energizer User Manual Step 4: Set the fence zone (1-6). Important: Each Fence Monitor requires a unique zone number. Insert ba eries into ba ery holder and replace in the Fence Monitor. Step 5: Replace the cover.
  • Page 37: Using Your Fence Monitor

    Gallagher 3E3618 i Series Energizer User Manual USING YOUR FENCE MONITOR Confi rm Fence Monitor is working by checking the zone indicator is displayed on the Energizer Controller. Zone 1 connected Note: If the zone is not displayed on the Energizer Controller, refer to Troubleshoo ng (p.
  • Page 38: Important Battery Information

    Gallagher 3E3618 i Series Energizer User Manual Important Battery Information • Only use Alkaline (AA) ba eries • Remove ba eries when not in use • Es mated ba ery life: 1-2 years Low ba ery indica on is shown on controller as below:...
  • Page 39: Choosing An Installation Location

    Gallagher 3E3618 i Series Energizer User Manual CHOOSING AN INSTALLATION LOCATION To get the best use of your Fence Monitor, it is wise to make a map of your farm and mark the loca ons of your Fence Monitors and the associated zones.
  • Page 40 Gallagher 3E3618 i Series Energizer User Manual Independent Leadouts Independent Zones...
  • Page 41 Gallagher 3E3618 i Series Energizer User Manual Advanced Fence Zoning Alterna vely, Fence Monitors can be installed on smaller areas within a larger area. If the fault is located in the smaller area and the larger area, then fault is most likely in the smaller area.
  • Page 42: Troubleshoo Ng

    Gallagher 3E3618 i Series Energizer User Manual TROUBLESHOOTING Problem Causes Solu on Fence Monitor zone Ba eries are fl at Replace ba eries does not appear on the Ba eries or ba ery holder are Install ba eries / ba ery...
  • Page 43: Alarm System

    ALARM SYSTEM...
  • Page 44: 3E3115 Alarm System User Manual

    Contents 3E3115 Alarm System User Manual Important Informa on ......................45 i-Series Alarm System ......................46 Quick Installa on Guide......................47 Advanced Features ........................48 LED Status Indicators ....................... 54 Fault Finding ..........................54 Specifi ca ons ........................... 54 External Ba ery ........................54...
  • Page 45: Important Informa On

    Note: Changes or modifi ca ons not expressly approved by Gallagher Limited could void the user’s authority to operate this equipment.
  • Page 46: I-Series Alarm System

    Standard mode - can be used with any Energizer • i-Series mode - if used in conjunc on with a Gallagher i-Series energizer (up to six Alarm systems can be connected to a Gallagher i-Series energizer). Status indica on LED...
  • Page 47: Quick Installa On Guide

    Gallagher 3E3618 i Series Energizer User Manual QUICK INSTALLATION GUIDE The following steps show how to quickly get the Alarm system up and running. Step Standard mode i-Series mode Set to standard mode. See If zone 6 is already used in the exis ng Zone Address Se ngs (p.
  • Page 48: Advanced Features

    Gallagher 3E3618 i Series Energizer User Manual ADVANCED FEATURES • Adjustable alarm levels • External inputs for door and PIR sensors • Adjustable alarm delay mes • Powered or Non-powered relay contacts • SMS connec on Adjustable Settings To alter the confi gura on of the Alarm System, remove from the wall and unscrew the 6 screws on the back of the unit.
  • Page 49 1. Zone Address se ngs Address se ngs Func on - i series 1 - 6 Adjustable unit zone address (for use with Gallagher i-Series fence energizers). Default is 6. Func on - standard mode Fence alarm OFF 1kV fence alarm threshold...
  • Page 50 Gallagher 3E3618 i Series Energizer User Manual 2. Func onal se ngs Switch Se ng OFF (Default) Relay 1 Latched Timed Relay 2 Timed Latched Relay 3 Latched Timed Fence alarms Local Global Unused Pulse monitoring One pulse missed 15 seconds (i-Series and...
  • Page 51: External Inputs

    Gallagher 3E3618 i Series Energizer User Manual External inputs ac vate External inputs such as a mo on sensor or reed switch can be connected. An alarm condi on will toggle only Relay 3 (default) OR Relay 1, Relay 2 and Relay 3 depending on the switch posi on.
  • Page 52 Gallagher 3E3618 i Series Energizer User Manual 5. Alarm me The Alarm Time is the period of me that the alarm stays on for and can be set to between 10 seconds (default) and 12 minutes. 10 sec 0 sec...
  • Page 53 Gallagher 3E3618 i Series Energizer User Manual Relay 1 powered N/O relay 1 Relay 1 Strobe Relay 2 powered Relay 2 N/O relay 2 Siren Relay 3 Relay 3 powered Ba ery...
  • Page 54: Led Status Indicators

    Gallagher 3E3618 i Series Energizer User Manual LED STATUS INDICATORS LED state Indicates Green con nuous Alarm system set and either powered by the AC adapter or a fully charged ba ery. Green fl ashing Alarms are set, but there is no RJ12 connec on to the energizer (i-Series mode only).