MACHINE INDICATIONS - PROBLEMS _ CAUSES _ REMEDIES
The machine can guide the user for a correct use through its multifunction indicator.
Machine on.
Machine off.
Machine warming up to brew coffee or dispen-
se hot water and/or steam.
Machine ready to brew espresso coffee or di-
spense hot water and/or steam.
Coffee function selected.
Hot water or steam function selected.
PROBLEMS
CAUSES
The machine does not turn
The machine is not
on.
connected to the power
supply.
The coffee is not hot
The cups are cold.
enough.
The pump makes a loud
No water in tank.
noise.
Pump not primed.
The machine takes a long
Excessive scale has built
time to warm up.
up.
The capsule holder does
The capsule is incorrectly
not fi t in place.
positioned.
REMEDIES
Move the main switch to ON.
Check the plug and the
connection
Warm up the cups.
Fill tank with water.
Prime the pump.
Descale the machine.
Check the position of the
capsule. If necessary, replace
it.