Safety Information General ❖ Observe all warnings that appear in this manual. ❖ This system is not intended to be used for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. ❖...
Safety Information (Cont.) Location Selection Location of a water treatment system is important. The following conditions are required: Level platform or floor. ❖ Total minimum pipe run to water heater of ten feet (three meters) to prevent backup of hot ❖...
Product Overview A. Product Characteristics - Manual function Regeneration is realized immediately by pressing manual button at any time. - Long outage indicator and parameter protect If outage override 3 days, the cursor of the time setting will flash to remind people to reset a new time of day.
Work Name Instruction mode Down-flow Timer The system will regenerate after the days set in “Set Regen Day” A-05 type Work by Day menu expire. Delayed The trigger time is set in “Set Regen Time” menu. Down-flow Timer The system will regenerate after the hours set in “Set Regen A-06 type Work by Hour Hour”...
A. When the water turbidity exceeds the condition, a filter should be installed on the inlet of control valve. B. When the water hardness exceeds the condition, the outlet water hardness will hardly reach the requirement of boiler feed water (0.03 mmol/L). It is suggested to adopt second grade softener. C.
System Specifications Model APR-1044-ELCD APR-1054-ELCD Recharge Style Downflow 10” 44” 10” 54” Tank Size (25.4111.76 cm) (25.4137.16 cm) Resin Volume 30 L 40 L Brine Tank Size 38.238.2X88.0 cm Salt Storage 216 kg or 100 L 216 kg or 100 L Rated Operating Flow Rate 1 - 1.2 m...
Product Installation A. Installation notice Before installation, read all these instructions completely, Then obtain all materials and tools needed for installation. The Installation of product, pipes and circuits, should be accomplished by professional to ensure that the product can operate normally. Performing installation is according to the relative pipeline regulations and the specification of Inlet, Outlet, Drain and Brine Line Connector.
Page 36
Fixings to fix the turbine, and insert the big adapter coupling at last. Insert the flow meter probe. 2. Install Bypass Valve or Valve Interface Figure 1-2 C (Using Bypass) Figure 1-2D (Using Valve Interface) Please make sure that the sizes of the two O-ring of Big Adapter Coupling are different, and please insert the large port of the Big Adapter Coupling to the bypass valve or the Valve interface.
Page 37
As the figure 1-3A and 1-3B shows, install a pressure gauge in water inlet. Inlet and outlet pipeline should be horizontal. Support inlet and outlet pipeline with fixed holder. a. Using Bypass valve connector As the figure 1-3A shows, install valve1 in the inlet pipe, install sample valve in the outlet pipe. b.
Page 38
Figure 1-4A Figure 1-4B Note : - Control valve should be higher than the sewer, and the length of the drain hose from the valve to the sewer should not be too long. - Be sure not to connect drain hose with the sewer, and leave a certain space between them, to prevent the waste water being sucked into the water treatment equipment, as is shown in the Figure 1- 5.
Basic Setting & Usage 1. The Function of Display and Buttons button lock indicator Lighting on indicates the buttons are locked. At this moment, any single button pressed will not work. Under any status, if there is no any operation within one minute, will light on the buttons will be locked.
Page 40
2. Basic Setting & Usage A. Parameter Specification Factory Parameter Set Parameter Name Instruction Default Range A-01 Down-flow regeneration, Meter Delayed A-02 Down-flow regeneration, Meter Immediate A-03 Down-flow regeneration, Intelligent Meter Delayed Work mode Down-flow regeneration, Intelligent Meter A-04 A-01 Immediate Down-flow regeneration, Timer type, Work by Day, A-05...
Page 41
B. Process Display (e.g. A-03) Figure A Figure B Figure C Figure D Figure E Figure F Figure G Figure H Figure I Figure J Figure K Figure L Explanation: - The display is shown in Figure K when it is powered on. - At the service position, the display is shown in Figure A/B/C/D circularly.
Page 42
- At the Brine & slow rinse position, the display is shown in Figure F. - At the Fast rinse position, the display is shown in Figure G - At the Refill position, the display is shown in Figure H. - When the valve turns from one working position to another, the display is shown in Figure I.
System Configuration and Flow Rate Curve A. Product Configuration Product configuration with tank, resin volume, brine tank and injector. The Minimum Salt Tank Size Resin Volume Flow Rate Brine Tank Consumption Injector (inch) Size (mm) Model Regeneration (kg) ø10” X 54” ø400X800 INJ-5 B.
3. Configuration for Standard Injector and Drain Line Flow Control Total flow Backwash/ Slow Tank Injector Injector rate of Brine Refill Fast Rinse Rinse Diameter DLFC Model Color Injector (inch) L/min L/min L/min L/min INJ-5 White 3.66 2.81 DLFC-3 14.4 Parameter Enquiry and Setting A.
Page 46
C. System Setting Menu List When the power of the valve is switched on, the display will show the valve type such as ASD4 for several seconds. During these seconds, if you press in order, you can enter the system setting menu.
Trial Running After installing the control valve on the resin tank with the connected pipes, as well as setting up the relevant parameter, please test run as follows: (Refer to the Figure 1-3B) A. Close the inlet valve1 and outlet valve2, and open bypass valve3. After cleaning the foreign material in the pipe, close bypass valve3.
Trouble-Shooting A. Control Valve Part Problem Cause Correction 1. Softener fails to A. Power off. A. Check the power supply (Check regenerate. fuse, plug, switch) B. Regeneration time setting is incorrect. B. Reset regeneration time. C. Controller is damaged. C. Replace controller. D.
Page 49
Trouble-Shooting (Cont.) Problem Cause Correction 5. Use too much salt. A. Excessive water in brine tank. A. See problem No.6. 6. Excessive water in brine A. Refilling time is too long. A. Reset correct refilling time. tank. B. Remain too much water after B.
Page 50
Problem Cause Correction connected with drain pipe. If the tank is used, put the outlet pipe on the tank, or install a solenoid valve or a check valve in outlet pipe to prevent the water in the tank flowing backwards. 11.
Page 51
Trouble-Shooting (Cont.) B. Controller part Problem Cause Correction 1. The display is garbled. A. Wiring of front panel with A. Check and replace the wiring. controller fails to work. B. Control board is faulty. B. Replace control board. C. Transformer damaged. C.
Warranty Terms and Conditions This product is warranted to be free from defects in material and workmanship for a period of one (1) year from the date of purchase*. This warranty is for does not cover accessories subject to wear and tear during usage (seals, o-ring, etc).
Duration time to replacement filter Duration time to change filter shown in the table below. In case the media have expired or deteriorated, please inquiries or purchases through the company's service. Media Life Picture When reaching 1 years, the filter should be changed but Resin depending on the quality of water in that area.
Page 54