Safety Information General Observe all warnings that appear in this manual. ❖ This system is not intended to be used for treating water that is microbiologically unsafe or of unknown quality ❖ without adequate disinfection before or after the system. Keep the unit in the upright position.
Safety Information (Cont.) Location Selection Location of a water treatment system is important. The following conditions are required: Level platform or floor. ❖ Total minimum pipe run to water heater of ten feet (three meters) to prevent backup of hot water into system. ❖...
Product specification 14.50 cm 148.70 cm 25.40 cm Model MPS-1054-R MPC-1054-R Tank Size 10” x 54” Valve Model BNT-631M (T) Filter Valve Media Sand Activated Carbon Flow rate /h (3,000 L/h) Duration of Backwash Cycle 10 - 15 minute Interval for backwash...
Product Installation A. Installation notice Before installation, read all these instructions completely, Then obtain all materials and tools needed for installation. The Installation of product, pipes and circuits, should be accomplished by professional to ensure that the product can operate normally. Performing installation is according to the relative pipeline regulations and the specification of Inlet, Outlet, Drain and Brine Line Connector.
Plumbing 1. When you are facing the front of the control valve, the left back is for connecting outlet adaptor, the right back is for connecting inlet adaptor, connect drain line adaptor on the left side. 2. Confirm the inlet pressure 1.5 - 6.0 bar, temperature 1 - 49 ºC, it must be installed a pressure reducer if the inlet pressure is over the maximum.
Trouble Shooting Issue Possible Solution 1.Fails to backwash - Inlet water pressure too low - Ensure the inlet water pressure more than 2 bar - Backwash pressure too low - Ensure the faucet closed when backwash or enough back pressure 2.
Warranty Terms and Conditions This product is warranted to be free from defects in material and workmanship for a period of one (1) year from the date of purchase*. This warranty is for does not cover accessories subject to wear and tear during usage (seals, o-ring, etc). *PROOF OF PURCHASE REQUIRED The unit must be used in operating conditions that conform to PEN K’s recommended design guidelines.
80% or use more Activated Carbon than 2 years. Model : MPS-1054-R Duration time to change filter shown in the table below. In case the media have expired or deteriorated, please inquiries or purchases through the company's service.
Page 28
PEN K INTER TRADING CO., LTD. HEAD OFFICE : 1000/63-64 PB TOWER. 16th Floor. Sukhumvit 71 Road, North Klongtan,Wattana, Bangkok 10110 TEL. 0-2493-6565 FAX : 0-2391-1141 SERVICE CENTER : 63/3 Moo 6 Soi Suksawat 76, Bangchak, Phra Pradaeng, Samut Prakan 10130 TEL.
Need help?
Do you have a question about the MPS-1054-R and is the answer not in the manual?
Questions and answers