Page 12
Content Safety Information ......................3 Specification ........................4 Product dimension ......................5 Filtering Process and Name of Each Part ................6 How to install the Product ....................7 - 9 How to Use ........................10 Filter Cartridge Replacement ..................... 11 Troubleshooting guide for RO system .................. 12 Warranty Terms and Conditions ..................
Safety Information General Observe all warnings that appear in this manual. This system is not intended to be used for treating water that is microbiologically unsafe or of un- known quality without adequate disinfection before or after the system. For cold water use only.
Specification Model X-STREAM IUF06 SUPLIER Water supply TDS Inlet <1000ppm Pressure Working 14.5 – 58 psi (1 – 4 bar) Flow rate 2.5 L/min Net Weight 11 kg Machine size L 47.8 X W 17.15 X H 53.3 cm 1st stage PP filter : (Period of change cartridge : 3 - 6 months)
Filtering Process and Name of Each Part Description Description Description T-Valve Four-Sides Valve High Pressure Valve PP Filter Check Valve CTO Filter Low Pressure Valve Inline Post carbon CTO Filter UF Membrane Faucet RESIN Filter Flow restrictor Inlet-Solenoid Valve Flashing Valve PEN K INTER TRADIND CO., LTD.| EN...
How to install the Product 1. Install the filters and membrane 1.1 Use wrench of housing to open clockwise the 3 housings, put the filters (PP, CTO, Resin) by turn (remove the wrapper of the filters), put the O-ring at right place, screw the housing tightly. 1.2 Use wrench of membrane housing to open the membrane housing, to put the membrane in (remove the wrapper), screw tightly.
Page 18
2.3 Measure the length between T-valve and the inlet water of UF machine (first stage which put PP). cut the PE pipe a little longer as the length, connect the PE pipe between them, Please see picture below. Connection method of PE pipe and quick fitting: Step 1 : take the retaining clip down, plug the PE pipe in.
Page 19
Install quick fitting Notice : retaining clip must be put back after connection to avoid water leakage. PEN K INTER TRADIND CO., LTD.| EN...
How to use 1. Turn on water supply valve and T-valve. 2. Open Faucet. 3. Check the whole system for leaks, tighten as necessary. 4. About 5 minutes later, the water starts dripping out of the faucet, let it flow for about 10 minutes. 5.
Filter Cartridge Replacement Caution : During this process, water will usually spill out. Please prepare a basin, towel, or other cleaning tools. In addition, the O-shaped seal ring cannot be damaged or lost; otherwise, water will severely leak. When fastening the filter cover, please try not to dislocate or deform the O-shaped seal ring.
Troubleshooting guide for UF system PROBLEM CAUSE SOLUTION Milky colored water 1. Air in system 1. Air in the system is a normal occurrence with initial start up of the RO system, will disappear by normal using with 1 to 2 week. The electric machine works 1.
Warranty Terms and Conditions This product is warranted to be free from defects in material and workmanship for a period of one (1) year from the date of purchase*. This warranty is for does not cover accessories subject to wear and tear during usage (seals, o-ring, etc).
Page 24
PEN K INTER TRADING CO., LTD. HEAD OFFICE : 1000/63-64 PB TOWER. 16th Floor. Sukhumvit 71 Road, North Klongtan,Wattana, Bangkok 10110 TEL. 0-2493-6565 FAX : 0-2391-1141 SERVICE CENTER : 63/3 Moo 6 Soi Suksawat 76, Bangchak, Phra Pradaeng, Samut Prakan 10130 TEL. 0-2493-6565 FAX : 0-2464-1600 E-mail : servicecenter@penk.co.th www.mexappliance.com...