Safety Warning
•
The installation should be carried out
by a qualified electrician in compliance
with the current edition of the IEE
Wiring Regulations.
•
Prior to installation, carry out the
necessary risk assessment considering
the people who could be at risk,
the level of risk and the precautions
required to control the risk
•
Ensure that the circuit supply is
isolated either by the circuit supply
fuse being removed or the applicable
Specification
Box Contents -
1 x Comet Floodlight and mounting bracket
CMT10-40: L: 131 W: 133 x D: 29mm. Weight: 0.392kg. Max Projected Area: 0.0101m2
CMT20-40: L: 131 x W: 133 x D: 29mm. Weight: 0.392kg. Max Projected Area: 0.0101m2
CMT30-40: L: 174 x W: 171 x D: 31mm. Weight: 0.597kg. Max Projected Area: 0.0181m2
CMT50-40: L: 216 x W: 212 x D: 32mm. Weight: 0.846kg. Max Projected Area: 0.0284m2
Dimensions:
CMT100-40/CMT100PC-40: L: 251 x W: 290 x D: 37mm. Weight: 1.445kg. Max Projected Area: 0.0459m2
CMT150-40/CMT150PC-40: L: 311 x W: 348 x D: 40mm. Weight: 2.12kg. Max Projected Area: 0.0683m2
CMT200-40/CMT200PC-40: L: 374 x W: 414 x D: 41mm. Weight: 3.09kg. Max Projected Area: 0.1014m2
CMT300-40/CMT300PC-40: L: 414 x W: 476 x D: 48mm.Weight: 4.36kg. Max Projected Area: 0.1376m2
Body: Die-Cast Aluminium
Material:
Lens: Tempered Glass
Working
Standard: -30°C - 45°C
Temperature:
Guarantee:
3 Years
3
10-300
YRS
WATT
GUARANTEE
MAXIMUM FITTINGS PER CIRCUIT
Automatic Circuit Breaker Type:
Rated Current:
Cable (mm):
CMT10-40
CMT20-40
CMT30-40
CMT50-40
CMT100-40/CMT100PC-40
CMT150-40/CMT150PC-40
CMT200-40/CMT200PC-40
CMT300-40/CMT300PC-40
Installation Instructions
Note: This is a Class I Luminaire - Earth connection is required
This is an IP65 rated product. Do not break or loosen any seals as this will affect the IP rating and will render the warranty void.
1.
Isolate the mains supply before commencing the installation.
2.
Ensure there is adequate free air circulation of at least 100mm around the luminaire. All luminaires run hot. It is the installer's responsibility to consider any
fire risks and take appropriate precautions.
3.
The nearest illuminated surface must be at least 0.5m from the front of the fitting.
4.
Do not install or use if the glass is broken. Replace the luminaire. The pre-wired cable is not replaceable. If it is damaged, replace the luminare.
5.
Select a suitable, solid mounting surface and fixings that are capable of holding the weight of the luminaire. Maximum installation height is ≤ 5m.
INSTALLATION INSTRUCTIONS
Comet Slim Floodlights / Comet Slim Floodlights with Photocell
Product Codes: CMT10-40, CMT20-40, CMT30-40, CMT50-40,
CMT100-40, CMT150-40, CMT200-40, CMT300-40, CMT100PC-40,
CMT150PC-40, CMT200PC-40, CMT300PC-40
IP65
4000K
B6
B10
B13
B16
6A
10A
13A
16A
1.5
1.5
1.5
2.5
25
25
25
25
25
25
25
25
25
25
25
25
16
25
25
25
8
13
17
21
5
9
11
14
4
6
8
10
2
4
6
7
circuit breaker being turned off before
installation or any maintenance.
•
Check the total load on the circuit
ensuring the luminaire does not exceed
the rating of the circuit cable, fuse or
circuit breaker.
•
Long-term use and voltage fluctuations
can reduce the life span of the fitting.
•
If the fitting incorporates control gear,
ensure careful sizing to avoid instances
of nuisance tripping of the protective
device used in the installation.
LED
230V
B20
C10
C13
C16
20A
10A
13A
16A
2.5
1.5
1.5
2.5
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
16
21
25
18
11
14
18
13
8
11
13
9
5
7
9
•
Follow the provided installation
instructions, using the fixings supplied
or recommended.
•
Keep out of reach of children.
Lmm
Dmm
1000-
IK07
30000LM
C20
20A
2.5
25
25
25
25
25
22
16
11
Wmm
Need help?
Do you have a question about the CMT10-40 and is the answer not in the manual?
Questions and answers