  • Page 1 Installation manual Pellet Outside Storage 1814 ENGLISH PE729EN...
  • Page 2 Title: Installation manual Pellet Outside Storage Article number: PE729EN Version valid from: 10/2024 Author ÖkoFEN Forschungs- & EntwicklungsgesmbH A-4133 Niederkappel, Gewerbepark 1 Tel.: +43 (0) 72 86 / 74 50 Fax.: +43 (0) 72 86 / 74 50 – 210 E-Mail: oekofen@pelletsheizung.at ©...
  • Page 3: Table Of Contents

    Contents Contents Dear Customer Intended use Types of safety warning sign Planning Pellet Outside Storage General Preparatory work Dimensions 4 Preparation surface Parts list 6 Structure base plate Structure fabric tank Structure base frame 9 Application foil Do-it-Yourself facade 10 Line routing...
  • Page 4: Dear Customer

    1 Dear Customer Dear Customer Thank you very much for your trust. With this quality product from ÖkoFEN, you are getting an innovative product with state-of-the-art technology. ÖkoFEN is Europe's specialist for really green heat. This manual is intended to help you operate the product safely, properly and eco- •...
  • Page 5: Types Of Safety Warning Sign

    2 Types of safety warning sign Types of safety warning sign The warning signs use the following symbols and texts. Types of safety warning sign Risk of injury Consequences of risk Avoiding risk DANGER Danger - indicates a situation that could lead to death or lifethreatening injury. ▶...
  • Page 6: Planning Pellet Outside Storage

    3 Planning Pellet Outside Storage Planning Pellet Outside Storage General Preparations Where and how are the suction lines, power supply for motor (5 x 1,5 mm ) and grounding (min. 6 mm ) routed into the house? Selection of suitable above- or below-ground cable routing and wall penetration incl.
  • Page 7: Preparatory Work

    3 Planning Pellet Outside Storage Preparatory work Secure location choice • Level surface, free from backwater Safety against slipping, accessibility for filling process • Excavate the soil at least 10 cm, compact and gravel. • Recommendation: • Align 7 pieces of concrete slabs (40x40x4 cm) in the scale. •...
  • Page 8: Dimensions

    3 Planning Pellet Outside Storage Variant 2 above ground line routing For above-ground piping, install a protective pipe with at least Ø DN160 and • bends with max. 45°. Install the wall duct by means of a pipe duct and a lining pipe (to be provided in •...
  • Page 9: Preparation Surface

    4 Preparation surface Preparation surface There are different regulations in the different European countries. Please mind the prescription of your country. Underground pipe - Ø 200 min. 500 The underground pipe can be placed to • the left or right of the central exposed aggregate concrete slab at the front of the fabric tank! b) Concrete slabs...
  • Page 10: Parts List

    5 Parts list Parts list Dimensions in Quan- Part Illustration tity Foot profile Middle foot profile Front|rear foot profile Installation manual...
  • Page 11 5 Parts list Dimensions in Quan- Part Illustration tity Base plate 27x500x1556 Base plate 27x248x1556 Angle connector Spacer boards rear 27x100x248 Installation manual...
  • Page 12 5 Parts list Dimensions in Quan- Part Illustration tity Spacer boards rear|side 27x100x196 Spacer boards side 27x127x196 Stand 50x80x2300 Longitudinal boards below 27x248x2244 Installation manual...
  • Page 13 5 Parts list Dimensions in Quan- Part Illustration tity Cross boards below 27x248x1608 Longitudinal profile roof 50x80x2244 Rafters 50x80x1554 Installation manual...
  • Page 14 5 Parts list Dimensions in Quan- Part Illustration tity Longitudinal boards top 27x300x2244 Cross boards top 27x300x1608 Longitudinal boards middle 27x196x2244 Installation manual...
  • Page 15 5 Parts list Dimensions in Quan- Part Illustration tity Cross board front middle 27x196x1608 Cross board front short - top 27x300x500 Upright extension 50x80x158 Cross board front short - middle 27x196x500 Installation manual...
  • Page 16 5 Parts list Dimensions in Quan- Part Illustration tity Cross board front short - below 27x248x500 Roof boards 27x500x2298 Roof board 27x109x2298 Door holder Installation manual...
  • Page 17 5 Parts list Dimensions in Quan- Part Illustration tity Grinding wheel Edge protection Foil Nail tape - 20 m roll Small parts Installation manual...
  • Page 18 5 Parts list Dimensions in Quan- Part Illustration tity Suction socket set wall connection - outside wall connection - inside Check the completeness of the delivery before starting assembly. Installation manual...
  • Page 19: Structure Base Plate

    6 Structure base plate Structure base plate Align the 2 outer foot profiles so that the outer edges of the foot profiles are flush with the outer edges of the exposed aggregate concrete slabs. Align the middle foot profile so that the support surface is in the same alignment as that of the outer foot profiles and ensure central positioning on the exposed aggre- gate concrete slab! Make sure that the surface is horizontal!
  • Page 20 6 Structure base plate Dimensions mounting screws 2. Screw the front and rear foot profiles to the base plates. 2200 2050 1950 1550 1450 1050 Specifications in mm No. 3 (2x) - 5x40 (10x) + ØM5 NOTICE Check the placement of the floor on the exposed aggregate concrete slabs! The outer edges of the foot profiles must be flush with the exposed aggregate con- crete slabs at the sides and front of the outer tank.
  • Page 21: Structure Fabric Tank

    7 Structure fabric tank Structure fabric tank Assemble the fabric tank according to the enclosed assembly instructions. NOTICE Place the 2 rear stands against the tab. Make sure they are parallel and positioned at a right angle. ▶ Check the diagonal dimension! Mounting of the drive unit NOTICE Observe motor alignment!
  • Page 22 7 Structure fabric tank Once the fabric tank has been fully assembled, all 4 stands must be screwed to the base plate using the enclosed fastening set (4x). NOTICE Ensure accurate perpendicular alignment before securing the fabric tank with the mounting kit.
  • Page 23: Structure Base Frame

    8 Structure base frame Structure base frame NOTICE Damage to the fabric The wood screws must not be countersunk too deeply and should be flush with the wood. Assembly of the spacer boards Carry out the process on both sides. NOTICE The side spacer boards must be aligned flush with the rear spacer boards.
  • Page 24 8 Structure base frame Assembly of the stands Carry out the process on both sides. 1. Place and screw the two stands to the sides of the fabric tank with the spacer boards (4x each side). No. 10 (4x) - 6x150 (8x) Installation manual...
  • Page 25 8 Structure base frame Assembly of the lower longitudinal and cross boards Carry out the process on both sides. 1. Place and screw the longitudinal board to the 2. Place and screw the cross board to the under- underside of the fabric tank with the spacer side of the fabric tank with the spacer boards (8x).
  • Page 26 8 Structure base frame Assembly of the front stands Carry out the process on both sides. 1. Place and screw the stands to the bottom of the 2. Screw the stands to the foot profile on the fabric tank with the longitudinal boards (2x on inside (2x on each side).
  • Page 27 8 Structure base frame Assembly of longitudinal profiles and rafters NOTICE The longitudinal profiles and rafters must be pre-drilled. 1. Place and screw the 2 longitudinal profiles to the 2. Place and screw the 2 longitudinal profiles to the stands. profiles.
  • Page 28 8 Structure base frame Assembly of the cross and longitudinal boards Carry out the process on both sides. 1. Place and screw the longitudinal board to the 2. Place and screw the rear cross board to the lon- longitudinal profiles of the roof and the uprights gitudinal profiles of the roof and the uprights.
  • Page 29 8 Structure base frame Assembly of the door stands 1. Place and screw the two stands to the foot pro- 2. Place and screw the two cross boards to the raf- file. ters and corner stands. No. 10 (2x) - 5x40 (4x) No.
  • Page 30 8 Structure base frame Assembly of the cross boards door 1. Place and screw the 4 cross boards to the stands. No. 21 (2x) + No. 22 (2x)- 5x70 (16x) Installation manual...
  • Page 31 8 Structure base frame Assembly roof 1. Place and screw the 4 roof boards. Screw the roof boards 2x to each rafter. The roof boards must be flush with the cross and longitudi- nal boards. No. 23 (3x) + No. 24 (1x) - 5x70 (48x) Mounting door holder 1.
  • Page 32: Application Foil

    9 Application foil Application foil Sand down edges and apply edge protection 1. Round off the outer edges of the entire outer 2. Place an edge protector at all four corners of the tank marked in red using the enclosed grinding roof and fasten each one with two nails.
  • Page 33 9 Application foil At least two people and a stepladder are needed to apply the foil. Unwrap the foil and make sure that the zipper is on the front side. Open both zippers to 20 cm. Place the foil on the roof and align it so that the foil can be pulled down at the corners.
  • Page 34: Do-It-Yourself Facade

    9 Application foil Do-it-Yourself facade The Pellet Outside Storage can be optionally clad with a do-it-yourself facade. Facade wood NOTICE Nail sealing tape Use the enclosed nail sealing tape to seal the outer tank. ▶ Screw the facade to the center of the nailing strip! Mount the nail sealing tape on the outside of the foil.
  • Page 35: Line Routing

    10 Line routing Line routing Mounting the connection flange on the outer tank For the line routing, the foil and the wood must be drilled through in the area of the discharge motor on the left or right side of a longitudinal board. Depending on the conditions on site, the placement of the line routing may vary.
  • Page 36 10 Line routing Mounting wall connection Check with the builder or an expert to determine the appropriate penetration for a brick wall. NOTICE Pellet hoses laid outdoors must be protected from UV radiation by a protective tube (provided by customer). ▶...