Fire By Design AWEIS Owner's Manual

All weather electronic ignition commercial grade system
Hide thumbs Also See for AWEIS:

Advertisement

www.FirebyDesign.com
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this equipment.
Do not store or use gasoline or other flammable vapors and liquids in vicinity of
this or any other appliance.
An LP-cylinder not connected for use shall not be stored in the vicinity of this or
any other appliance.
FOR OUTDOOR
USE ONLY
If you smell gas:
Installation must conform with local codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1 / NFPA 54, or International Fuel Gas Code.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in
the absence of local codes, with the National Electric Code, ANSI/NFPA 70, if applicable.
WARNING
For Use with NATURAL or LP GAS Only
NO SOLID FUELS TO BE USED WITH THIS SYSTEM
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from appliance and immediately call your
gas supplier or fire department.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING
WARNING
WARNING
DANGER
1
All Weather Electronic Ignition
Commercial Grade System
Owner's Manual
Installation and Operation
(ROUND/SQUARE FEATURES)
Certified by
Lab Test Certification
Meets: ANSI Z21.97-2014
CSA 2.41-2014
CSA C22.2 No. 3-M1998 (R2014)
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which
has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such
as a camper, tent car or home.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AWEIS and is the answer not in the manual?

Questions and answers

Summary of Contents for Fire By Design AWEIS

  • Page 1 All Weather Electronic Ignition Commercial Grade System Owner’s Manual Installation and Operation www.FirebyDesign.com (ROUND/SQUARE FEATURES) Certified by Lab Test Certification Meets: ANSI Z21.97-2014 CSA 2.41-2014 CSA C22.2 No. 3-M1998 (R2014) WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
  • Page 2 AVERTISSEMENT Une installation, un ajustement, une modification, une réparation ou un entretien inapproprié peuvent être la cause de blessures ou de dommages. Veuillez lire attentivement les instructions d'installation, d'utilisation et d'entretien avant d'installer ou de réparer ce matériel. AVERTISSEMENT Ne pas entreposer ni utiliser de l'essence ni d'autres vapeurs ou liquides inflammables dans le voisinage de l'appareil, ni de tout autre appareil.
  • Page 3 Table of Contents Gas and Electrical Requirements Page 4 Pilot Burner Daisy Chain Wiring Requirement Page 4 Assembly Clearance from Combustibles Page 5 Installation Page 5 Acceptable Media for Fire Features Page 8 Installation of Media in Fire Features Page 8 Operation Page 9 LP Air Mixer...
  • Page 4 Recommended Wire Size 12-gauge wire for all installations Daisy Chain Wiring of Multiple AWEIS The Fire by Design AWEIS have a Yellow and a Blue wire protruding from them. These are the power wires. When daisy chaining multiple AWEIS the polarity between them must be the same.
  • Page 5: Clearance From Combustibles

    Turn on the gas supply and then, using a soapy water solution spray the bottom of the AWEIS where it is connected to the gas line to ensure no leaks exist.
  • Page 6 Natural Gas Orifice LP Air Mixer Orifice LP Air Mixer Configured for Install Natural Gas Orifice, Coupling & Pipe Nipple 5. The photo at right shows what the AWEIS looks like just prior to installing the burner pan...
  • Page 7 6. Install the Burner Pan. You will need to line up the Opening for the Pilot Burner with the Pilot Burner. You will notice that the hole in the center of the pan (for the pipe nipple coming from the Ignition Control Box) and the opening for the Pilot Burner are much larger than needed.
  • Page 8: Installation Note

    Acceptable Media for Fire Features 1” above ring WARNING Do not use any other material as filler/topping media inside fire features other than those listed below. Using improper media inside a fire feature could result in damage to property or injury to persons nearby due to media ‘popping’...
  • Page 9: Operation

    Illustrations showing Completed Installations Illustration of Properly Installed AWEIS Illustration of Properly Installed AWEIS (Natural Gas) (Propane) Fire Ring / Burner Pilot Burner Fire Ring / Burner Pilot Burner (Holes Facing Up) Assembly (Holes Facing Up) Assembly Natural Gas Orifice...
  • Page 10 2. Turn fire feature on by turning on the electrical device used to power the fire feature. Sequence of Operation during Ignition - Power is applied - Hot Surface Igniter (Glow Plug) becomes hot and 4 seconds later the Pilot Gas Valve opens - Within 10 seconds of power application Pilot Flame should be visible (at night only) - Within 10 seconds of Pilot Flame Ignition burner (fire ring/burner bar) should ignite Fire Feature Shutdown...
  • Page 11: Replacement Parts

    Replacement Parts Part Name Part # Item Letter Pilot Burner Assembly Ignition Control Box Pilot Burner Cage Auxiliary Pilot Burner Gas Line APBG Primary Pilot Burner Gas Line PPBG Pilot Burner Orifice 24 Volt AC Transformer 24VAC Troubleshooting I installed the Electronic Ignition System, turned it on and nothing happened When this occurs it is usually due to an electrical wiring / power issue.
  • Page 12 power and when they see they have a minimum of 24 volts they think everything is fine electrically so there must be a problem with the Electronic Ignition System. The problem is not due to the volts but rather the amps. The number of amps reaching the fire feature is heavily dependent on the gauge wire used between the transformer and the fire feature.
  • Page 13 Attachment 1 Automated Pool Controller Wiring...