  • Page 1 2 3 / 1 2 – 5 3 9 0 0 1 6 _ 0 1 T r a n s l a t i o n o f O r i g i n a l i n s t r u c t i o n s User manual REMOTE CONTROL w w w .
  • Page 2 Dear customer,Thank you for choosing an Aermec product. It is the fruit of many years of experience and special design studies and has been made of the highest grade materials and with cutting edge technology.In addition, all our products bear the CE mark indicating that they meet the requirements of the European Machine Direc- tive regarding safety.
  • Page 3: User Notice

    USER NOTICE — The wired controller is universal. — By pressing a key for a function that is not available, the unit will not change the operating status. — Never install the wired controller in the moist circumstance or expose it directly under the sunlight. —...
  • Page 4: Table Of Contents

    TABLE OF CONTENTS User Notice Setting or cancelling a programmed SWITCH OFF ......................3 (TIMER Off ) ..................10 Remote control ..................5 Activating / Deactivating the extended ventilation User interface (buttons) .............5 (X-FAN) ..................11 User interface (display) ..............6 3.10 Activating / Deactivating the indoor unit’s display ..11 Functions available through the remote control ....7 3.11...
  • Page 5: Remote Control

    REMOTE CONTROL Attention: — Some of the buttons of the remote control are not used for the required air conditioner and are therefore not described in these instructions. Pressing of these keys will not affect the operation of the air conditioner. —...
  • Page 6: User Interface Display

    2.2 USER INTERFACE DISPLAY Remote control display icons available Table of contents Functions represented by the icons Indicates the AUTOMATIC mode is active Cooling mode Dry mode Indicates the VENTILATION mode is active Heating mode Indicates the current fan setting Indicates the setting has been transmitted to the receiver located on the indoor unit Indicates the battery charge level Indicates the WiFi function is active...
  • Page 7: Functions Available Through The Remote Control

    FUNCTIONS AVAILABLE THROUGH THE REMOTE CONTROL 3.1 SWITCHING THE INDOOR UNIT ON AND OFF 3.2 SETTING THE OPERATING SETPOINT By pressing the button it is possible to switch the unit on or off. When All the operating modes (except the automatic one) require an room air tempera- ON/OFF off...
  • Page 8: Selecting An Operating Mode

    3.3 SELECTING AN OPERATING MODE 3.4 SETTING THE VENTILATION SPEED Sets the operating mode Setting the ventilation speed ON/OFF ON/OFF SAVE SAVE COOL HEAT COOL HEAT QUIET TIMER SLEEP QUIET TIMER SLEEP X-FAN X-FAN LIGHT WiFi LIGHT WiFi E-HEATER E-HEATER If the unit is on, pressing the button allows passing from one operating mode Pressing the...
  • Page 9: (Swing)

    3.5 SETTING THE MOTORISED VERTICAL DISCHARGE FIN 3.6 SETTING THE MOTORISED HORIZONTAL DISCHARGE SWING FIN SWING Motorised discharge vertical fin setting Motorised discharge horizontal fin setting ON/OFF ON/OFF SAVE SAVE COOL HEAT COOL HEAT QUIET TIMER SLEEP QUIET TIMER SLEEP X-FAN X-FAN LIGHT...
  • Page 10: Setting Or Cancelling A Programmed Switch On Timer On

    3.7 SETTING OR CANCELLING A PROGRAMMED SWITCH 3.8 SETTING OR CANCELLING A PROGRAMMED SWITCH ON TIMER ON OFF TIMER OFF The units possess a timer used to program switching on by specifying the time that The units possess a timer used to program switching off by specifying the time that you want the unit to deactivate.
  • Page 11: Activating / Deactivating The Extended Ventilation X Fan

    3.9 ACTIVATING / DEACTIVATING THE EXTENDED 3.10 ACTIVATING / DEACTIVATING THE INDOOR UNIT’S VENTILATION X FAN DISPLAY During the operation in cooling or dehumidification mode the condensate caused The display on the indoor unit must be activated using the remote control; To ac- by the humidity in the air is formed on the heat exchanger within the unit.
  • Page 12: Activate / Deactivate The Night Wellness (Sleep) Function

    3.11 ACTIVATE / DEACTIVATE THE NIGHT WELLNESS 3.12 ACTIVATE OR DEACTIVATE THE WIFI FUNCTION SLEEP FUNCTION WiFi With the unit switched on, press the button to activate the WiFi device in the The night-time comfort function controls the unit in an optimal way during the indoor unit.
  • Page 13: Setting Or Removing The Button Lock

    This function prevents any accidental changes to the settings. Please scan the QR code to download the EWPE manual Setting the button lock Italian: http://www.aermec.com/qrcode.asp?q=15587 English: ON/OFF SAVE COOL HEAT http://www.aermec.com/qrcode.asp?q=15588...
  • Page 14: Activate / Deactivate The Energy Saving

    3.15 ACTIVATE / DEACTIVATE THE ENERGY SAVING 3.16 COOLING MODE COOL The power saving function is activated only during the cooling mode; This function COOL Press to activate cooling mode directly. allows you to reach the set temperature with less energy consumption. Set the cooling mode SAVE If the power is on and the cooling mode is selected, pressing the...
  • Page 15: Activate / Deactivate Auto Clean Function

    3.18 ACTIVATE / DEACTIVATE AUTO CLEAN FUNCTION REPLACING THE REMOTE CONTROL’S BATTERIES ATTENTION: Function only available for SCG_1 series units. Under off status, hold “ ” and “ ” buttons simultaneously for 5 seconds to turn on or turn off the auto clean function. The remote controller temperature display area will flash “CL”...
  • Page 16 SCARICA L’ULTIMA VERSIONE: DOWNLOAD THE LATEST VERSION: TÉLÉCHARGER LA DERNIÈRE VERSION: http://www.aermec.com/qrcode.asp?q=16629 http://www.aermec.com/qrcode.asp?q=16630 http://www.aermec.com/qrcode.asp?q=16631 A e r m e c S . p . A . V i a R o m a , 9 9 6 - 3 7 0 4 0 B e v i l a c q u a ( V R ) - I t a l i a T e l .