CP SERIES
ULTRA QUIET HIGH
PERFORMANCE EXHAUST FANS
OPERATION INSTRUCTIONS AND PARTS MANUAL
PLEASE READ AND SAVE THESE INSTRUCTIONS
OPERATION INSTRUCTIONS AND PARTS MANUAL
PLEASE READ AND SAVE THESE INSTRUCTIONS
MODELS: CP50, CP80
The purpose of this manual is to aid in the proper installation and operation of the CP Series exhaust fans. These instructions are intended
to supplement good general practices and are not intended to overwrite local codes and ordinances.
IT IS THE RESPONSIBILITY OF THE PURCHASER TO ENSURE THAT THE INSTALLATION AND MAINTENANCE OF THIS
EQUIPMENT IS HANDLED BY QUALIFIED PERSONNEL.
Inspect all shipments carefully for damage. THE RECEIVER MUST NOTE ANY DAMAGE ON THE CARRIER'S BILL OF LADING AND
FILE A CLAIM IMMEDIATELY WITH THE FREIGHT COMPANY.
GENERAL SAFETY
1.
Use this unit only in the manner intended by the manufacturer. If you have questions,
contact the manufacturer at the address or telephone number listed in the warranty.
2.
Before servicing or cleaning unit, switch power off at service panel and lock the service
disconnecting means to prevent power from being switching on accidentally. When the
service disconnecting means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3.
Installation work and electrical wiring must be done by a qualified person(s) in accordance
with all applicable codes and standards, including fire-rated construction codes and
standards.
4.
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6.
Ducted fans must always be vented to the outdoors.
7.
Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
8.
This unit must be grounded.
9.
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
10.
This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
11.
To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
12.
Please read specification label on product for further information and requirements.
Please follow all applicable national, state/provincial and local codes. All of them will supersede this manual.
13.
14.
Failure to follow the safety instructions in this manual may cause serious injury or death due to electrical shock or high
speed rotating parts.
CLEANING AND MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting
brush attachment.
M-CP 11/24
Page 1 of 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CP Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Canarm CP Series

  • Page 1 MODELS: CP50, CP80 The purpose of this manual is to aid in the proper installation and operation of the CP Series exhaust fans. These instructions are intended to supplement good general practices and are not intended to overwrite local codes and ordinances.
  • Page 2: Operation

    CP SERIES ULTRA QUIET HIGH PERFORMANCE EXHAUST FANS OPERATION Use an on/off switch to operate this fan. See Electrical Wiring Connection section for details. PLAN THE INSTALLATION 1. Do not use in a cooking area. 2. Two ways to connect ductwork to a factory-shipped unit.
  • Page 3 CP SERIES ULTRA QUIET HIGH PERFORMANCE EXHAUST FANS ASSEMBLY INSTRUCTIONS CONTINUED 2. Mount with hanger bars. a. Sliding hanger bars have been provided, which allow the housing to be positioned accurately anywhere between the framing. The bars span up to 24 in. and can be used on all types of framing: I-joist, standard joist,and truss construction.
  • Page 4: Electrical Wiring Connection

    CP SERIES ULTRA QUIET HIGH PERFORMANCE EXHAUST FANS ASSEMBLY INSTRUCTIONS CONTINUED 6. Install duct and blower assembly. Hole a. Install duct from the inside of the housing. Fix. the duct by the tab. b. Attach the blower assembly to the housing by 3 screws.
  • Page 5: Grille Installation

    WARRANTY CANARM Ltd. warrants every new fan to be free of defects in material and workmanship to the extent that, within a period of one year from the date of purchase CANARM Ltd. shall either repair or replace at CANARM’s option, any unit or part thereof, returned freight prepaid and found to be defective.
  • Page 6: Sécurité Générale

    SÉRIE CP VENTILATEURS D'EXTRACTION ULTRA SILENCIEUX À HAUTE PERFORMANCE OPERATION INSTRUCTIONS AND PARTS MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS MODE D’OPÉRATION LIRE ET GARDER CES INSTRUCTIONS MODÈLES: CP50, CP80 Ce manuel a pour objectif de fournir un guide pour l'installation et l'utilisation correcte du ventilateur d'extraction de la série CP. Ces instructions sont destinées à...
  • Page 7: Opération

    SÉRIE CP VENTILATEURS D'EXTRACTION ULTRA SILENCIEUX À HAUTE PERFORMANCE OPÉRATION Utilisez un interrupteur marche/arrêt pour faire fonctionner ce ventilateur. Consultez la section Connexion du câblage électrique pour plus de détails. PLANIFIER L'INSTALLATION 1. Ne pas utiliser dans une zone de cuisson. 2.
  • Page 8 SÉRIE CP VENTILATEURS D'EXTRACTION ULTRA SILENCIEUX À HAUTE PERFORMANCE INSTRUCTIONS DE MONTAGE SUITE 2. Montage avec barres de suspension. a. Des barres de suspension coulissantes ont été fournies, ce qui permet de positionner le boîtier avec précision n'importe où entre les ossatures. Les barres s'étendent jusqu'à...
  • Page 9 SÉRIE CP VENTILATEURS D'EXTRACTION ULTRA SILENCIEUX À HAUTE PERFORMANCE INSTRUCTIONS DE MONTAGE SUITE 6. Installer l’ensemble conduit et ventilateur. Trou a. Installer le conduit depuis l'intérieur du boîtier. Fixer le conduit à l'aide de la languette. b. Fixez l’ensemble du ventilateur au boîtier à l’aide de 3 vis. Trou Trou 7.
  • Page 10: Installation De La Grille

    CANARM LTD. Garantie que chaque nouveau ventilateur est exempt de défauts matériels et de fabrication dans la mesure où, dans un délai d’un an à compter de la date d’achat, CANARM Ltd. réparera ou remplacera, au choix de Canarm, toute unité ou pièce de celle-ci, retourné...