ENDA ATSP4 MULTI FUNCTIONAL ANALOG TIMER
Thank you for choosing ENDA ATSP4 Multi Functional Analog Timer
* 48 x 48mm sized.
* Triggering whit supply voltage.
* Contact output for timing function (OUT).
* 6 Different timing modes for OUT (A, B, C, D, E, F).
* 6 Different timing unit selections for OUT (S,10S, M, 10M, H, 10H).
* Suitable for 8 pin octal or 5 screw-terminal connection.
* CE marked according to European Norms.
ORDER CODE
ATSP4 - xV - xxx - xx
Product Basic Code
Panel Mounted
Multi Function Analog Timer
Supply Voltage
UV
90-250V AC
LV
24V AC/DC
Connection Diagram
ENDA ATSP4 is intended for installation in control panels. Make sure that the device is used only for intended
purpose. The electrical connections must be carried on by a qualified staff and must be according to the relevant
locally applicable regulations. During an installation, all of the cables that are connected to the device must be free of
electrical power. The device must be protected against inadmissible humidity, vibrations, severe soiling. Make sure
that the operation temperature is not exceeded. All input and output lines that are not connected to the supply
network must be laid out as shielded and twisted cables. These cables should not be close to the power cables or
components. The shielding must be grounded on the instrument side.
ENDA
ENDA
INDUSTRIAL ELECTRONICS
INDUSTRIAL ELECTRONICS
ATSP4-UV-K05-01 ANALOG MULTI TIMER
ATSP4-UV-S08-12 ANALOG
8 6 8 04 0 7 7 0 94 6 5
8 680407 709588
4
5
3
2
1
8
SUPPLY
90-250V AC
50/60Hz 10VA
CONTACT
250V AC 8A
Made in Turkey
Made in Turkey
RESISTIVE
SN: XXXXXXXXX
SN: XXXXXXXXX
LOAD
NOTE :
Fuse
SUPPLY :
Switch
F 100 mA 250V AC
90-250V AC
90-250V AC
or
(24V AC/DC)
Supply
(24V AC/DC)
Fuse should
Cable size : 1,5mm²
be connected
Power
indicator
PWR
10
5
0
Scale
ENDA
S
01
0 ... 1,2
10S
03
0 ... 3
10H
M
H
12
0 ... 12
ATSP4
10M
30
0 ... 30
60
0 ... 60
Timing unit
Connection Type
5 Pin screw-terminal
K05
8 Pin octal
S08
ENDA
INDUSTRIAL ELECTRONICS
ATSP4-LV-S08-30 ANALOG
MULTI
TIMER
MULTI
TIMER
8 680407 709649
4
5
6
3
6
2
7
7
1
8
-
+
SUPPLY
24V AC/DC
50/60Hz 10VA
CONTACT
CONTACT
250V AC 8A
250V AC 8A
Made in Turkey
RESISTIVE
RESISTIVE
SN: XXXXXXXXX
LOAD
LOAD
1) Mains supply cords shall meet the requirements of IEC
60227 or IEC 60245.
2) In accordance with the safety regulations, the power supply
switch shall bring the identification of the relevant
instrument and it should be easily accessible by the
operator.
Technical Specifications
ENVIRONMENTALCONDITIONS
Ambient/storage temperature
Relative humidity
Rated pollution degree
Height
Do not use the device in locations subject to corrosive and flammable gasses.
ELECTRICALCHARACTERISTICS
Control output
Supply voltage
state indicator
Power consumption
Connection
Scale
OUT
Reset time
Accuracy
15
20
EMC
Safety requirements
25
Insulation test voltage
30
OUTPUTS
Control output (OUT)
F
Life expectancy for relay
Control output state
E
A
B
D
CONTROL
C
Timing function
Timing unit
Timing mode
HOUSING
Housing type
Dimensions
Weight
Enclosure metarial
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
Dimensions
PWR
5
0
S
10S
10H
M
H
10M
1 / 2
0 ... +50°C/-25 ... 70°C (There shouldn't be icing or condensation on the environment.)
80% Relative humidity for temperatures up to 31°C, decreasing linearly to 50% at 40°C.
According to EN 60529
Front panel
Rear panel
Maximum 2000m
90-250V AC, 50/60Hz or 24V AC/DC, 50/60Hz.
Maximum 10VA
8 Pin octal connector or 5 Pin screw-terminal .
0-1.2 , 0-3 , 0-12 , 0-30 or 0-60.
0.3 Seconds for ATP4-UV, 0.01 seconds for ATP4-LV.
Depending on the effect of supply voltage
Depending on the set value settings
Depending on the effect of temperature
EN 61326-1: 2006
EN 61010-1: 2010 (pollution degree 2, over voltage category II)
3kV AC min. 1 minute, 4,2kV DC min. 1 minute.
Relay: 250V AC, 8A (resistive load), NO+NC
Without load 30.000.000 operation; 250V AC, 8A resistive load 100.000 operation.
OUT Led lights up when there is power at the output control, it is flashes as long as the timer is running.
A, B, C, D, E, F Modes can be selected on device.
Second, 10 seconds, minute, 10 minutes, hour, 10 hours units can be selected on device.
Suitable for flush-panel mounting or rail mountable 8/11 pin octal connector.
W48xH48xD82mm
Approx. 100g (after packing)
Self extinguishing plastics
2
1
OUT2
OUT
1
15
10
20
67mm
25
14mm
30
82mm
1
ENDA
F
E
A
B
D
ATSP4
C
48mm
2
1
: IP50
: IP20
: max %0.2
: max %5
: max %1
Panel cut-out
51mm
46mm
8 Pin octal
connector
Note :
Panel thickness
should be
maximum 3mm.
Connection
For removing the device
cables
from the panel:
- Push in the mounting clamps
in direction 1.
- Then, pull out the device
in direction 2.
5 Pin
Screw-terminal
Connector
ENDA
ATSP4-xV-xxx-xx-EN-02-220103
TM
Need help?