Page 2
WARNING BEFORE USING AN ICE BATH ALWAYS consult your doctor before using an ice bath, especially if you have any ● health issues! Children and vulnerable adults must always be supervised when in the vicinity of a ● water-filled ice bath, and should never enter due to risk of drowning or getting health issues from cold water.
If the chiller unit stops working or doesn't work when switched on, unplug it immediately ● and DO NOT use. LUMI accepts no responsibility for the users misuse or failure to use this equipment ● safely as instructed.
Page 4
WIFI ENABLED minichiller Your can control your LUMI Mini Chiller™ unit either via the built in display or WIFI enabled mobile app for ease of use. QUALITY BUILD The LUMI Mini Chiller™ PLUG & PLAY unit is the industry's best...
3. Complete the steps in the QUICK START GUIDE to assemble your LUMI product. CUSTOMER SUPPORT If you have any questions about setting up or using your LUMI product, please visit our website for further information, faqs, troubleshooting and customer support.
ONLINE RESOURCES Download and read Learn more about your user manual your product www.lumitherapy.co.uk/pages/product-manuals www.youtube.com/@lumitherapy...
Page 7
FOLLOW US ON SOCIAL MEDIA www.lumitherapy.co.uk www.instagram.com/@lumi.therapy www.facebook.com/@Lumitherapyuk www.youtube.com/@lumitherapy...
Page 8
INTRODUCTION GETTING TO KNOW YOUR MINI CHILLER Front Rear 1. LED control panel with touch sensitive 6. Air bleed valve. buttons. 7. Power connection. 2. Cooling fan (do not cover). 8. Power ON/OFF switch. 3. Water out (connect to WATER IN on bath).
Valve Valve and inflated your LUMI ice bath Open Closed first before continuing. 2. Place the LUMI chiller on a Front stable flat surface next to your LUMI ice bath, leaving a recommend 50cm space around the chiller unit for ventilation.
Page 10
5. Attach the Stop Valves to the LUMI ice bath (connect only the short thread to the ice bath). 6. Next, connect both water pipes between the Stop Valves and chiller unit; ensure the pipes are hand tight and the valves are first set to the Closed position.
Page 11
FILLING THE ICE BATH WITH WATER 1. Ensuring all valves are first set to the Closed position, you can now begin to fill your LUMI ice bath with cold water. 2. Stop filling once the water level reaches just below the Water In hole on the ice bath before moving to the next step.
Page 12
FIRST USE - SWITCHING ON THE CHILLER 1. Tap (do not hold) the button to switch the unit ON/OFF. ON/OFF 2. After a few seconds, the chiller should start circulating the ice bath water, and can take up to a few minutes to push any remaining air out of the system and start chilling the water. 3.
Page 14
LED CONTROL PANEL INTRODUCTION* Please note: The LED display buttons are all touch-sensitive, and react to both single touch and hold functions. 1. Power ON/OFF (single touch ON/OFF) 7. WiFi ON/OFF 2. Set temperature / Program menu 8. Water pump 3.
Page 15
POWER ON AND GENERAL OPERATION 1. Single tap the button to turn the chiller unit on (single tap to turn off). ON/OFF 2. Tap to adjust the required temperature (3°C - 45°C), tap to confirm. 3. Hold the button for 3 seconds to lock and unlock the screen. PROGRAM MENU Program Specification...
Page 16
3. The Tuya, or Smart Life mobile app can now be used to detect, and connect to the chiller WiFi pairing signal. 4. Once successfully paired, the WiFi icon will remain lit (not flashing). Control your LUMI chiller FAULT CODES via an iOS / Android app* Water temperature sensor broken.
Page 17
*Tuya Smart & Smart Life mobile apps are both 3rd party apps, LUMI accepts no responsibility for incompatibility or issues when using this with your LUMI chiller unit. - At present, Tuya Smart can only support a 2.4G WiFi signal.
Page 18
DRAINING YOUR ICE BATH AND CHILLER OF WATER You have a few options to drain and empty both your ice bath and chiller of water, when you want to clean, maintain or store the products for future use. OPTION 1. - MANUALLY DRAIN THE SYSTEM Ensure your chiller is Switched off and unplugged.
Page 19
Though not essential, to ensure a long service life and for hygiene purposes, we recommend draining, cleaning and drying your LUMI chiller every two to three weeks. Repeat all the steps in the QUICK START section, whenever you use the chiller unit again.
Page 20
MANUFACTURER SPECIFICATIONS Model No. LUMI Mini Chiller™ Power Supply AC220-240V 50/60Hz Input Power 350W Compressor Power 250W Cooling Capacity 770W Cooling Function Heating function Refrigerant R134A Water Temp. 3 - 42°C / 37.4 - 107.6°F Water Filter Pre-installed (removable) Circulation Pump...
Page 21
MANUFACTURER SPECIFICATIONS (CONTINUED) Model No. LUMI Mini Chiller™ Depending on ambient air temperature, season (i.e. summer or winter), starting water Water Volume & Cooling Time temperature, or where and how your ice bath has been setup; as a guide, it can take up to 24 hours to chill 400-500 litres of water from 18°C (64.4°F) down to 3°C (37.4°F).
TROUBLESHOOTING Issue Possible causes Solution No power input. Check if the mains power cord is plugged in • The chiller has no power. and switched on. • The LED control RCD safety has been activated. Press the RESET button on the RCD power panel does not block.
Page 24
United Kingdom THERE Access our library of free personal training videos and guides on our website to learn ARE NO how to get the most out of your LUMI product LIMITS and achieve the results you want. lumitherapy.co.uk @lumi.therapy @Lumitherapyuk...
Need help?
Do you have a question about the mini chiller and is the answer not in the manual?