  • Page 1 USER MANUAL cubeCHILLER...
  • Page 2 WARNING BEFORE USING AN ICE BATH ALWAYS consult your doctor before using an ice bath, especially if you have any ● health issues! Children and vulnerable adults must always be supervised when in the vicinity of a ● water-filled ice bath, and should never enter due to risk of drowning or getting health issues from cold water.
  • Page 3: Electrical Warning

    If the unit does get wet, unplug it immediately and do not use. If the chiller unit stops working or doesn't work when switched on, unplug it immediately ● and DO NOT use. LUMI accepts no responsibility for the users misuse or failure to use this equipment ● safely as instructed.
  • Page 4 QUALITY BUILD WATER FILTER cubeCHILLER The LUMI Cube Chiller™ is the The LUMI Cube Chiller™ industry's best mini chiller and not only chills, but it COMPACT & PORTABLE filtration combination, low helps keep your ice Unlike some large bulky ice...
  • Page 5: Customer Support

    3. Complete the steps in the QUICK START GUIDE to assemble your LUMI product. CUSTOMER SUPPORT If you have any questions about setting up or using your LUMI product, please visit our website for further information, faqs, troubleshooting and customer support.
  • Page 6: Online Resources

    ONLINE RESOURCES Download and read Learn more about your user manual your product www.lumitherapy.co.uk/pages/product-manuals www.youtube.com/@lumitherapy...
  • Page 7 FOLLOW US ON SOCIAL MEDIA www.lumitherapy.co.uk www.instagram.com/@lumi.therapy www.facebook.com/@Lumitherapyuk www.youtube.com/@lumitherapy...
  • Page 8 INTRODUCTION GETTING TO KNOW YOUR CHILLER Side Front 1. LED control panel. 7. Water out (chilled water). 2. Cooling fan. 8. Power cable. 3. Drain valve. 9. Power RCD block. 4. Handle (both sides). 10. RCD test button (power off). 5.
  • Page 9 GETTING TO KNOW YOUR CHILLER (CONTINUED) RCD power safety block Rear Filter casing + filter Pipes + adaptors The power cable has a built-in RCD safety block* (residual current device), a safety device that switches off electricity automatically if there is a fault. * Power cable and RCD block may look slightly different to the illustration, but will work in the same way.
  • Page 10 @lumitherapy 1. Ensure you have assembled and inflated your LUMI ice bath first before continuing. 2. Place the LUMI chiller on a stable flat surface next to your LUMI ice Front bath, leaving a recommend 50cm space around the chiller unit for ventilation.
  • Page 11 8. Next, screw on the cam-lock adaptors to the male adaptors hand-tight (do not overtighten). IF YOU HAVE THE LUMI RECOVERY ULTRA ICE BATH 9. The LUMI Recovery Ultra comes with 'male adaptors' built-in, so all you need to do is wrap the PTFE tape clockwise and tight around each thread of these male adaptors 10 times.
  • Page 12 QUICK START - STEP 2 CONNECTING THE FILTER 1. Once you have connected the male adaptors and/or cam-lock adaptors to your ice bath, you can add PTFE tape to the 'Water Out' thread on the chiller (tightly wrap 10x), and screw on the cam-lock adaptor. 2.
  • Page 14 QUICK START - STEP 3 CONNECTING THE CHILLER AND FILLING THE ICE BATH WITH WATER 1. Once you have connected the filter and adaptors to your ice bath and chiller unit, using a hose, connect the 'Water out' from the chiller to the 'Water in' on your ice bath. 2.
  • Page 15 FILLING THE ICE BATH WITH WATER 1. Ensuring that both cam-lock hoses are connected, you can now begin to fill your LUMI ice bath up with cold water. 2. Stop filling once the water level reaches the 'Water inlet' hole on the ice bath.
  • Page 16 FIRST USE - SWITCHING ON THE CHILLER 1. Connect the power cable to an AC socket that is suitable for use, properly grounded, has a built in surge protector and preferably is IP65 rated. 2. The power cable has a built-in RCD safety block (residual current device), a safety device that switches off electricity automatically if there is a fault.
  • Page 17 LED CONTROL PANEL INTRODUCTION* Power ON/OFF Heating * Water pump Settings menu Auto on/off * Overheating * Increase temperature (+) Cooling mode Current temperature Decrease temperature (-) WiFi * POWER ON AND GENERAL OPERATION 1. Press the button to turn the chiller unit on (press to turn off). 2.
  • Page 18: Additional Settings

    ADDITIONAL SETTINGS There are two settings menus: - one is locked and cannot be changed, while the other allows limited adjustments. However, we recommend keeping the default settings to ensure optimal performance and avoid potential damage to the chiller. ACCESSING SETTINGS MENU 1 1.
  • Page 19: Accessing Settings Menu

    ACCESSING SETTINGS MENU 2 1. Press the to switch off the chiller (display should say OFF). 2. Press and hold for three seconds to access the secondary menu. 3. Press to select a setting. 4. Press to access and change the value with the buttons.
  • Page 20 DRAINING YOUR ICE BATH AND CHILLER OF WATER You have a few options to drain and empty both your ice bath and chiller of water, when you want to clean, maintain or store the products for future use. IF YOU HAVE USED THE ANGLED STOP-VALVES First ensure your chiller is Switched off and unplugged.
  • Page 21: Maintenance, Cleaning & Storage

    Though not essential, to ensure a long service life and for hygiene purposes, we recommend draining, cleaning and drying your LUMI chiller every two to three weeks. Repeat all the steps in the QUICK START section, whenever you use the chiller unit again.
  • Page 22: Main Features

    MAIN FEATURES Model No. LUMI Cube Chiller™ (LCC01) Depending on ambient air temperature, season (i.e. summer or winter), starting water Water Volume & Cooling Time temperature, or where and how your ice bath has been setup; as a guide, it can take For reference only up to 24 hours to chill 400-500 litres of water from 18°C (64.4°F) down to 3°C (37.4°F).
  • Page 23 MANUFACTURER SPECIFICATIONS Model No. LUMI Cube Chiller™ (LCC01) Power Supply AC220-240V 50Hz Max Input Power 600W Compressor Power 400W Cooling Capacity 800W Cooling Function Heating function Refrigerant R-32 / 150g Water Temp. 2 - 42°C / 35.6 - 107.6°F (default min. temperature set to 4°C)
  • Page 24: Troubleshooting

    TROUBLESHOOTING Issue Possible causes Solution No power input. Check if the mains power cord is plugged in • The chiller has no power. and switched on. • The LED control RCD safety has been activated. Press the RESET button on the RCD power panel does not block.
  • Page 25 Dimensions: 33(W) x 37.5(D) x 35.5(H)cm Weight: 20kg AC input: 220-240V Cooling power: 800W Refrigerant: R-32 / 150g Warranty: 1 year limited warranty Manufactured for LUMI by: GUANGDONG EXINDA TECHNOLOGY CO. LTD. Butterfly Ridge Industrial Zone, Xiantang Town, Dongyuan County, Heyuan City,...
  • Page 26 United Kingdom THERE Access our library of free personal training videos and guides on our website to learn ARE NO how to get the most out of your LUMI product LIMITS and achieve the results you want. lumitherapy.co.uk @lumi.therapy @Lumitherapyuk...