Summary of Contents for Wascomat D750S

  • Page 1 Installation manual Tumble dryer D750S Type N3... 438905769/US 2024.02.01 Wascomat Commercial Laundry Equipment 516-371-4400 www.wascomat.com...
  • Page 2: Tech Support

    WARRANTY CLAIMS Wascomat’s Technical Support Staff will honor valid manufacturer’s parts warranty claims providing your Wascomat machines are registered for warranty coverage upon installation. If they are not registered, you can validate your warranty claim by providing information about when and where you purchased the Wascomat machine(s), the model and serial number(s).
  • Page 3: For Your Safety

    Safety WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death or property damage. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: Do not try to light any appliance.
  • Page 4 Safety WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
  • Page 5 Safety WARNING: The dryer is intended for use only with fabrics that have been washed with water. WARNING: To avoid fire hazard, do not dry articles containing foam rubber or similarly textured rubberlike materials. WARNING: ALL OPERATING AND MAINTENANCE PROCEDURES SHOWN ON THE NEXT PAGE OF THIS MANUAL MUST BE FOLLOWED DAILY FOR PROPER OPERATION OF YOUR MACHINE.
  • Page 6 Safety NOTICE TO: OWNERS, OPERATORS AND DEALERS IMPROPER INSTALLATION AND INADEQUATE MAINTENANCE, POOR HOUSEKEEPING AND WILLFUL NEGLECT OR BYPASSING OF SAFETY DEVICES MAY RESULT IN SERIOUS ACCIDENTS OR INJURY. TO ASSURE THE SAFETY OF CUSTOMERS AND/OR OPERATORS OF YOUR MACHINE, THE FOLLOWING MAINTENANCE CHECKS MUST BE PERFORMED ON A DAILY BASIS. Prior to operation of the machine, check to make certain that all operating instructions and warning signs are affixed to the machine and legible.
  • Page 7: Notice To Installer

    Refer to complete installation instructions provided in manuals accompanying the machine. Contact Wascomat Technical Support with any questions BEFORE installing this machine. Damage resulting from inadequate installation materials or improper installation techniques will...
  • Page 8: Electrical Information

    Safety Electrical Information It is your responsibility to have ALL electrical connections (including grounding) made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms with local and state regulations or codes. In the absence of such codes, ALL electrical connections, material, and workmanship must conform to the applicable requirements of the NATIONAL ELECTRIC CODE ANSI/NFPA NO.
  • Page 9: Gas Information

    Safety Gas Information It is your responsibility to have ALL plumbing connections made by a qualified professional to insure that the installation is adequate and conforms with local and state regulations or codes. In the absence of such codes, ALL plumbing connections, material, and workmanship must conform to the applicable requirements of the National Fuel Gas Code ANSI Z223.1 or the CAN/CGA-B149, INSTALLATION CODES - both the latest edition.
  • Page 10 Safety Natural Gas If the pressure is too low, ignition failure and/or slow drying times may result. Excessively high supply pressure will result in erratic operation of the gas valves internal pressure regulator. Further information in section: Gas connection. Propane Gas Dryers made for use with propane gas have the gas valve pressure regulator blocked open, so that the gas pressure must be regulated upstream of the dryer.
  • Page 11: Table Of Contents

    Contents Contents 1 Safety Precautions ..........................13 Additional safety precautions for gas heated tumble dryer ............15 General safety information......................15 Commercial use only........................15 Copyright ..........................15 Symbols..........................16 2 Technical data...........................17 Drawing ..........................17 Technical data .........................18 3 Setup ...............................19 General...........................19 Unpacking ..........................19 Siting ............................20 Connection to network......................21 Mechanical installation ......................21 4 Evacuation system ..........................22...
  • Page 13: Safety Precautions

    Installation manual 1 Safety Precautions • Servicing shall be carried out only by authorized personnel. • Only authorized spare parts, accessories and consumables shall be used. • The machine is not to be used if industrial chemicals have been used for cleaning. •...
  • Page 14 Installation manual • A-weighted emission sound pressure level at working stations: 70 dB(A).
  • Page 15: Additional Safety Precautions For Gas Heated Tumble Dryer

    The machine/machines covered by this manual is/are made for commercial and industrial use only. 1.4 Copyright This manual is intended solely for consultation by the operator and can only be given to third parties with the permis- sion of Wascomat company.
  • Page 16: Symbols

    Installation manual 1.5 Symbols Caution Caution, hot surface Caution, high voltage Warning, risk of fire / flammable material Danger, crush hazard Read the instructions before using the machine...
  • Page 17: Technical Data

    Installation manual 2 Technical data 2.1 Drawing fig.W00530 Operating panel Door opening, ⌀ 687 mm / ⌀ 27 1/16 inch Electrical connection Gas connection Exhaust connection 1336 2086 1310 1238 inch 34 3/16 52 5/8 82 1/8 1 5/16 51 9/16 48 3/4 1084 inch...
  • Page 18: Technical Data

    Installation manual 2.2 Technical data Weight, net Drum volume litres 2 x 423 2 x 15 Drum diameter inch 32 3/4 Drum depth inch 29 13/16 Drum speed 43–44 Rated capacity, filling factor 1:18 (Max. load) 2 x 23.5 2 x 51.8 Rated capacity, filling factor 1:22 (Recommended load) 2 x 19.2 2 x 42.3...
  • Page 19: Setup

    Installation manual 3 Setup 3.1 General The principle work flow to setup or install this machine is as follows: 1. Unpacking 2. Positioning/siting, levelling or/and securing the machine. 3. Correcting the fresh air/air intake's size, exhaust duct's size and pipe(s) connections in considering a stand-alone machine or sharing exhaust duct.
  • Page 20: Siting

    Installation manual Remove the machine from the pallet. Note! When moving the machine, handle it with care. The drum has no transport clamps. Place the machine on its final position. 3.3 Siting The figure shows recommended distance to walls and/or other machines. D=C+B 1= Top view 2 = Side view on built in machine...
  • Page 21: Connection To Network

    Installation manual 3.4 Connection to network If several machines are to be connected to a network, the knock-outs (A) in the side panels must be removed before installation. A bushing for network cables must be installed from the inside in the right-hand side panel. The bushing must be pushed right through the hole in the left-hand side panel on the side of the machine.
  • Page 22: Evacuation System

    Installation manual Securing the machine to the floor To ensure steadiness of the machine it is important to fasten the machine to the foundation. Fasten the four fittings (A) to the foundation using four x M10 set screws (B). If the four fittings are not supplied, order kit No.
  • Page 23: Fresh Air

    Installation manual 4.2 Fresh air For maximum efficiency and the shortest possible drying time, it is important to ensure that fresh air is able to enter the room from the outside at the same time it is being exhausted by the machine. To avoid creating a draught in the room it is important to place the make-up air inlet behind the machine.
  • Page 24 Installation manual Maximum duct length With 1 elbow With 2 elbow With 3 elbow 2 pockets (10” duct) 85 ft 65 ft 45 ft 1 pocket (8” duct) 85 ft 70 ft 55 ft Exhaust illustrations The end of the exhaust duct must never be exposed to wind pressure. Wind Unacceptable Wind...
  • Page 25: Shared Exhaust Duct

    Installation manual 4.4 Shared exhaust duct It is recommended that each machine is connected to a separate exhaust duct. When several machines shall use the same exhaust duct the exhaust duct must increase before each machine is added. The individual ducts should enter the main duct at an angle of 45° or less and in the direction of airflow. The recommended diameter increase progression is the one in the table.
  • Page 26: Gas Connection

    Installation manual 5 Gas connection 5.1 General Caution It is your responsibility to have all plumbing connections made by a qualified professional to insure that the gas plumbing installation is adequate and conforms with local and state regulations or codes. In the absence of such codes, ALL plumbing connections, material, and workmanship must conform to the applicable requirements of the National Fuel Gas Code ANSI Z223.1 LATEST EDITION or the CAN/CGA—B149, INSTALLATION CODES, both the latest edition.
  • Page 27: Test Run

    Installation manual When a machine with liquid petroleum gases shall be installed or used on high altitude (2001 feet and higher) a kit for high altitude must be installed. For kit No. please refer to the spare parts list. 5.4 Test run Note! Before test run the machine, ensure that the air flow/static back pressure has been adjusted accorded to the "Evacuation system"...
  • Page 28: Converting Instructions

    Installation manual 5.5 Converting instructions • Disconnect the power to the machine. • Demount the back panel. • Demount the air restriction plate (1). • Demount the nozzle (2) and mount the new supplied nozzle. • Re-mount the air restriction plate. fig.X01068 •...
  • Page 29: Data Label

    Installation manual 5.6 Data label When the machine is to be converted to another gas type, the data label at the rear of the machine must be updated in order for the data to be correct. Place the data label enclosed in the conversion kit on top of the data label as shown below. If there are more than one data label, select the label with the correct country code and gas type.
  • Page 30: Electrical Connection

    Installation manual 6 Electrical connection 6.1 Electrical installation It is your responsibility to have ALL electrical connections (including grounding) made by a properly licensed and competent electrician, to assure that the electric installation is adequate and conforms with local and state regu- lations or codes.
  • Page 31: Three-Phase Connection

    Installation manual 6.3 Three-phase connection Demount the upper rear cover panel. Connect the earth and other wires as shown. L1 L2 L3 L2 L3 3NAC L1 L2 L3 N 3NAC 3NAC L2 L3 When the installation is completed remount the cover panel and check: •...
  • Page 32: Electrical Connections

    Installation manual 6.4 Electrical connections Heating alternative Main voltage Heating power Total power Recommended fuse ITCB Gas heated 120V 1 ~ 1.55 208–240V 1 ~ 1.55...
  • Page 33: At First Power Up

    Installation manual 7 At first power up When the installation is complete and the power is connected for the first time you will be forced to make the following settings. When one setting is ready you will automatically enter the next one. Follow the instructions on the display. •...
  • Page 34: Function Check

    Installation manual 8 Function check May only be carried out by qualified personnel. A function check must be made when the installation is finished and before the machine can be ready to be used. Whenever a repair has been made, a function check must be performed before the machine can be used again. Check the automatic stop of the machine •...
  • Page 35 Installation manual If the direction is wrong, swap two of the three phases to the left on the connection terminal. fig.7119 Check the heat • Let the machine work for five minutes on a program with heat. • Check that the heating is working by opening the door and feel if there is heat in the drum. Ready to use If all tests are OK the machine is now ready to be used.
  • Page 36: Disposal Information

    Installation manual 9 Disposal information 9.1 Disposal of appliance at end of life Before disposing of the machine, make sure to carefully check its physical condition, and in particular any parts of the structure that can give or break during scrapping. The machine’s parts must be disposed of in a differentiated way, according to their different characteristics (e.g.