Advertisement

Operating Manual
CROSSOVER
SERIES
D R Y E R I N S T A L L A T I O N M A N U A L
DOC. NO. 096008
EDITION 28.2019

Advertisement

Table of Contents
loading

Summary of Contents for Wascomat CROSSOVER 2.0 Series

  • Page 1 Operating Manual CROSSOVER SERIES D R Y E R I N S T A L L A T I O N M A N U A L DOC. NO. 096008 EDITION 28.2019...
  • Page 2 IMPORTANT SAFETY INSTRUCTION Purchaser and user should consult local gas supplier for proper instructions to be followed in the event user smells gas. WARNING To reduce the risk of fire, electric shock, or injury to persons when using your appliance, follow basic precautions, including the following: •...
  • Page 3 WARNING FIRE OR EXPLOSION HAZARD • Failure to follow safety warnings exactly could result in serious injury, death or property damage. • Do not store or use gasoline or other flammable vapors and liqids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: •...
  • Page 4 Model Numbers Electric DLHF0 CEMI DLHF0 DLHS0 CEMI DLHS0 DLHF0817EMI DLHF0817E DLHS0817EMI DLHS0817E DLHF0817GMI DLHF0817G DLHS0817GMI DLHS0817G...
  • Page 5 Installation Instructions Install the clothes dryer according to the manufacturer’s instructions and local codes. WARNING Risk of Fire • Clothes dryer installation must be performed by a qualified installer • Do not install a clothes dryer with flexible plastic venting materials. If flexible metal (foil type) duct is installed, it must be of a specific type identified by the appliance manufacture as suitable for use with clothes dryers.
  • Page 6 NOTICE TO: OWNERS, OPERATORS AND DEALERS IMPROPER INSTALLATION AND INADEQUATE MAINTENANCE, POOR HOUSEKEEPING AND WILLFUL NEGLECT OR BYPASSING OF SAFETY DEVICES MAY RESULT IN SERIOUS ACCIDENTS OR INJURY. TO ASSURE THE SAFETY OF CUSTOMERS AND/OR OPERATORS OF YOUR MACHINE, THE FOLLOWING MAINTENANCE CHECKS MUST BE PERFORMED ON A DAILY BASIS.
  • Page 7 NOTICE TO INSTALLER Improper installation of this machine: • May cause serious damage to the machine. • May result in other property damage. • May cause personal injury. • Will void the manufacturer’s warranty. Location Requirements • The dryer must be installed on a sound level floor capable of supporting its weight. Carpeting must be removed from the floor area that the dryer is to rest on.
  • Page 8: Table Of Contents

    Contents Technical Data / Specifications ................1:1 Installation ......................2:1 Installation Procedures ................2:1 Location Requirements ................2:1 Unpacking / Setting Up ................2:1 Enclosure Requirements ................2:2 Stand Alone / Washer-Dryer Stack / Dryer-Dryer Stack Installation... 2:2 Fresh Air Supply ..................2:3 Exhaust Requirements ................2:3 Outside Ductwork Protection ..............2:4 Venting (Single / Horizontal / Vertical and Multiple) ........2:4 Electrical Requirements ................2:6...
  • Page 9 Technical Data / Specs MAXIMUM CAPACITY (DRY) 22 lb 10 kg TUMBLER DIAMETER 26 in 66 cm TUMBLER DEPTH 20.8 in 53 cm TUMBLER VOLUME 7.7 cu ft 0.22 cu m TUMBLER/DRIVE MOTOR 1/3 hp 0.25 kW BLOWER DRIVEN BY BLOWER/FAN MOTOR TUMBLER MOTOR DOOR OPENING (DIAMETER)
  • Page 10 Safety Precautions Please observe all safety precautions displayed on the equipment and/or specified in the installation manual included with the dryer. For your safety, the instructions in this manual must be followed to minimize the risk of fire or explosion and to prevent property damage, personal injury, or loss of life.
  • Page 11 Warnings • Remove articles from the dryer as soon as the drying cycle has been completed. • The operation of this appliance may affect the operation of other types of gas appliances, which take their air for safe combustion from the same room. If in doubt, consult the appliance manufacturer(s). •...
  • Page 12: Technical Data / Specifications

    Technical Data Stand Alone Dryer Washer Dryer Stack (inches/cm)
  • Page 13 Technical Data Dryer Dryer Stack (inches/cm)
  • Page 14: Installation Procedures

    Installation Installation Procedures Installation should only be performed by qualified individuals in accordance with local, state, and national codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1- LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO.
  • Page 15 Installation Dryer Enclosure Requirements Commercial • Bulkheads and partitions are recommended to be made of noncombustible material. • The requirement to allow the door to open completely is 36 inches (91 cm). • A minimum overhead clearance of 6-inches (15.24 cm) is recommended. •...
  • Page 16: Exhaust Requirements

    Installation Fresh Air Supply Requirements When the dryer is operating, it draws in room air, heats it, passes this air through the tumbler, and exhausts it out of the building. The room air must be continually replenished from the outdoors (make-up air).
  • Page 17: Outside Ductwork Protection

    Installation wherever possible. All ductwork should be smooth inside with no projections from sheet metal screws or other obstructions, which will result in lint accumulation. Duct sections must be oriented for proper airflow (consult duct supplier) and all joints must be taped to prevent moisture and lint from escaping.
  • Page 18 Installation ductwork must be 4-inches (10 cm). No more than 1 elbow should be used in the exhaust duct run (including tumbler/dryer elbow connections or elbows used for outside protection from the weather). If more than 1 elbow is used, the cross-sectional area of the ductwork must be increased. Vertical Venting If vertical dryer venting is used, the length of the ductwork from the dryer to the outside exhaust outlet, must not exceed 12 feet (3.5 meters).
  • Page 19: Electrical Requirements

    Installation Electrical Requirements All electrical connections must be made by a properly licensed qualified electrician. This is to ensure that the electrical installation is adequate and conforms to local, state, and national codes in the country of installation. In the absence of such codes, all electrical connections, materials, and workmanship must conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO.70-LATEST EDITION or in Canada, the Canadian Electrical Codes Parts 1 &...
  • Page 20 Installation Wiring Connections / Hookup Electric Heated Models When local codes allow, the electrical supply of the dryer may be connected by means of a new power supply cord kit, marked for use with a dryer, that is U.L. listed and rated at a minimum of 120/240 volts, 30-ampere with three No.
  • Page 21: Gas Information

    Installation Wiring Connections / Hookup Gas Heated Model All gas model dryers are 120 volts and come with an integrated 3-prong NEMA plug intended for connection to a dedicated branch receptacle. Gas Information Gas installation and adjustment must be done by qualified, licensed personnel. It is your responsibility to have all plumbing connections, materials, and workmanship comply with national and local codes in the country of installation.
  • Page 22 Installation WARNING • Fire or explosion could result due to failure to isolate or disconnect the gas supply as noted. The dryer must be connected to the type of heat/gas indicated on the data label and the correct pressure must be confirmed. If this is not possible, do not connect the dryer. Contact the reseller who sold the dryer or the manufacturer.
  • Page 23 Installation 2:10 WARNING • Never test for leaks with a flame!!! WARNING • This appliance must only be operated with the gas type indicated on the dryer’s data plate. If the appliance is converted (gas type changed), a data plate amendment must be obtained from the manufacturer (dryer’s serial number is required to purchase a conversion kit).
  • Page 24: Gas Pressure Adjustment

    Installation 2:11 Gas Pressure Adjustment Disconnect electrical power to the dryer. Gas (burner) pressures are measured with the burner in operation for all burner adjustment conditions. Therefore once the necessary adjustments have been made, the dryer must be operated in a heating cycle to verify that the pressure is correct. If it is not correct, you must discontinue the power to the unit and make further adjustments.
  • Page 25 Pre Operational Instructions The following items should be checked before attempting to operate the dryer: • Read all “IMPORTANT” AND “WARNING” labels attached to the dryer. • Check incoming supply voltage to be sure that it is the same as indicated on the data label. •...
  • Page 26: Preoperational Instructions

    Pre Operational Instructions Electrical Heated Dryers • Turn on electric power to the dryer. • Run the “No Heat” drying program and check if the drum is rotating properly. • Check to ensure that electric oven/contactor assembly is activating. • Run the “Low Heat”...
  • Page 27: Coin Meter Installation And Blocking Plate

    Shutdown Instructions If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed: • Disconnect power to the dryer either at the external disconnect switch or the circuit breaker. Gas Models •...
  • Page 28: Preventive Maintenance

    Preventive Maintenance Cleaning A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer, as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location. Maximum operating efficiency is dependent upon proper airflow.
  • Page 29 Preventive Maintenance To be carried out by qualified personnel. Every 6 Months (Refer this service to qualified personnel) • Inspect and remove lint accumulation external exhaust ductwork and from dryer’s internal exhaust ducting. • The accumulation of lint in the exhaust ductwork can create a potential fire hazard. •...
  • Page 30 Sales and Administration: (516) 371-4400 Spare Parts: (516) 371-2000 Technical Support: (516) 371-0700 En Mexico: 001-800-010-1010 461 Doughty Blvd., Inwood, NY 11096 laundrylux.com...

Table of Contents