SOLINTEG EBS-B Series User Manual

High voltage storage system

Advertisement

Quick Links

S o l i n t e g E B S - B S e r i e s
H i g h V o l t a g e S t o r a g e S y s t e m
E B S - S 5 K 1 - B , E B S - S 7 K 5 - , E B S - S 1 0 K- B
E B S - S 1 2 K- B , E B S - S 1 5 K- B , E B S - S 1 7 K- B
E B S - S 2 0 K- B , E B S - S 2 3 K- B , E B S - S 2 5 K- B
User Manual
ENGLISH VERSION

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EBS-B Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SOLINTEG EBS-B Series

  • Page 1 S o l i n t e g E B S - B S e r i e s H i g h V o l t a g e S t o r a g e S y s t e m E B S - S 5 K 1 - B , E B S - S 7 K 5 - , E B S - S 1 0 K- B E B S - S 1 2 K- B , E B S - S 1 5 K- B , E B S - S 1 7 K- B E B S - S 2 0 K- B , E B S - S 2 3 K- B , E B S - S 2 5 K- B...
  • Page 3 The products, services or features purchased are subject to the commercial contracts and terms of Solinteg Power Co., Ltd. All or part of the products, services or features described in this document may not be within the scope of purchase.
  • Page 4: Table Of Contents

    Safety Instructions ……………………………………… 1.1 Environment Requirements …………………………………………………… 6 1.2 Safety Guidelines ………………………………………………………………… 6 1.3 Personnel Requirements ………………………………………………………… 7 1.4 Precautionary Statement and Response ……………………………………… 7 1.4.1 Battery Leakage ………………………………………………………………………… 7 1.4.2 Fire ………………………………………………………………………………………… 8 1.5 Hazard Statement ……………………………………………………………… 8 1.6 Statement ………………………………………………………………………… 9 Product Introduction ……………………………………...
  • Page 5 Maintenance and Troubleshooting …………………… 6.1 Maintenance …………………………………………………………………… 34 6.2 Troubleshooting ……………………………………………………………… 36 Appendix …………………………………………………… 7.1 Technical Parameters ………………………………………………………… 37 7.1.1 Components of EBS-B Storage System …………………………………………… 37 7.1.2 Energy Storage System ……………………………………………………………… 39 7.2 Contact Information ………………………………………………………… 42...
  • Page 6: Safety Instructions

    User Manual EBS-B series Safety Instruction 1.1 Environment Requirements This product is designed for indoor operation. It must be installed in a location complying with following: •Temperature: -10~55°C •Storage temperature: 0~45°C •Relative humidity: 5% ~ 95%RH •Ground shall be flat and level.
  • Page 7: Personnel Requirements

    User Manual EBS-B series figuration of whole system (including inverter, battery, PV, load, utility grid, etc.) in accor- dance with corresponding manual before operation. •Do not dispose in fire, mix with other battery types, charge above specified rate, connect improperly, or short circuit, which may result in overheating, explosion or leakage of cell contents.
  • Page 8: Fire

    User Manual EBS-B series 1.4.2 Fire • Carbon dioxide, Novac1230, or FM-200 fire extinguishers shall be equipped near the equipment. • Extinguish the fire before battery catching fire. • If battery on fire, evacuate people immediately without any hesitation. 1.5 Hazard Statement This product is a "Hazardous Chemical"...
  • Page 9: Statement

    User Manual EBS-B series 1.6 Statement Solinteg Power Co., Ltd. has the right not to undertake quality assurance in any of the fol- lowing circumstances: ① Damages caused by improper transportation. ② Damages caused by incorrect storage, installation or use.
  • Page 10: Product Introduction

    User Manual EBS-B series Product Introduction 2.1 Appearance Introduction 2.1.1 Controller Module The definition and description of controller’s ports are shown as below: Item Terminal Note Battery negative socket Battery positive socket Inverter communication connection port LINKA/INV Battery parallel connection port...
  • Page 11: Battery Module

    User Manual EBS-B series 2.1.2 Battery Module Top View of Battery Module Bottom View of Battery Module Item Terminal Note Lifting Handle Input of Power Supply Terminal Decompression Valves Stack Battery Slot Output of Power Supply Terminal 2.1.3 Base Module...
  • Page 12: Paraller

    User Manual EBS-B series 2.1.4 Paraller Paraller is only needed when multiple battery clusters are parallel connected, and it sup- ports at most 3 battery clusters. If only 1 battery cluster is equipped in the system, please skip this part.
  • Page 13: Indicator

    User Manual EBS-B series 2.2 Indicator The status of power indicator and its corresponding explanation are shown as below: Indicator Status Description The battery is powered off. The breaker is switched on, and the battery is waiting for Flash green and red lights alternately entering self-checking.
  • Page 14 User Manual EBS-B series...
  • Page 15 User Manual EBS-B series Item Quantity Remark Controller Module(EBS-C) With PE terminal and its screw Battery Module(EBS-B2K5-B) 2~10 Based on one battery cluster Base Module(EBS-A) Battery Terminal 1 pcs RJ45 Waterproof Connector Controller Module Mounts Stabilize controller module M4*8 Countersunk Screw...
  • Page 16: Installation

    User Manual EBS-B series Installation 3.1 Installation Requirements ① The area is completely water proof. The floor is flat and level. ② There are no flammable or explosive materials. ③ The ambient temperature is within the range from 0 to 50℃ .
  • Page 17: Controller And Battery Modules Mounting

    User Manual EBS-B series ③ Remove dust-proof label on power supply terminal. 3.2.2 Controller and Battery Modules Mounting ① Remove dust-proof label on power supply terminal. ② Place the battery modules on the base one by one slightly, and please note that the...
  • Page 18 User Manual EBS-B series ③ Install controller module mounts on both sides of controller module. ④ Mark the position of 4 holes to be drilled on the wall.
  • Page 19 User Manual EBS-B series ⑤ Remove controller module. ⑥ Use a Ф8 drill bit for the wall hole 80mm deep, and put expansion tubes into them. Hole depth:80mm Before drilling, be sure to avoid water pipes and wires buried in the wall.
  • Page 20 User Manual EBS-B series ⑧ Tighten all M4*12 countersunk screws at both side of all battery modules and controller module. ⑨ Insert the expansion screws into the tubes, then fix the mounts onto the wall with expansion screws by using a cross screwdriver.
  • Page 21: Paraller Mounting

    User Manual EBS-B series 3.2.3 Paraller Mounting ① According to the location of battery cluster, select a proper location for paraller. ② Mark the position of 2 holes to be drilled on the wall. ③ Use a Ф8 drill bit for the wall hole 80mm deep, and put expansion tubes into them.
  • Page 22: Ground Connection

    User Manual EBS-B series 1. Before drilling, be sure to avoid water pipes and wires buried in the wall. 2. Due to the risk of falling and injury, the paraller requires 2 people to install. ④ Insert the expansion screws into the tubes, then fix the Paraller onto the wall with expansion screws by using a cross screwdriver.
  • Page 23 User Manual EBS-B series ③ The cross-sectional area of the external grounding cable is 6mm². Grounding Steps of Paraller ① The external grounding port is located at the bottom of paraller. ② Fix the grounding terminal to the PE wire with a proper tool and lock the grounding terminal to the grounding port at the bottom of paraller.
  • Page 24: Connection With Mhs/Mht Series

    User Manual EBS-B series Connection with MHS/MHT Series 4.1 Single Battery Cluster 4.1.1 Electrical Wiring Diagram After mechanical installation is finished, please follow the instructions to complete the power cable and communication cable connections. 4.1.2 Power Cable Connection Before starting connecting the power cable, please obey the following requirements to ensure personal safety: ①...
  • Page 25 User Manual EBS-B series 2.Peel off the battery cable insulation sleeve for 10 mm. 10mm 3.Take out the battery terminals in the accessory bag. 4.Insert the positive and negative cables into the corresponding connectors, and then press the terminal with crimping pliers. After assembling, try to pull back the battery cable to ensure that the terminal is tightly attached in the connector.
  • Page 26: Communication Cable Connection

    User Manual EBS-B series ① Before connecting to the inverter, please make sure the polarity of the cable is correct. ② Use a multi-meter to measure the voltage of the battery pack and make sure that the voltage is within the inverter limitation and the polarity is correct.
  • Page 27: Multiple Battery Clusters With Paraller

    User Manual EBS-B series 4.2 Multiple Battery Clusters with Paraller The paraller supports at most three battery clusters to be parallel connected, which means the storage of whole battery system can reach 76.8kWh. 4.2.1 Electrical Wiring Diagram After mechanical installation is finished, please follow the instructions to complete the power cable and communication cable connections.
  • Page 28 User Manual EBS-B series 2.Peel off the battery cable insulation sleeve for 10 mm. 10mm 3.Take out the battery terminals in the accessory bag. 4.Insert the positive and negative cables into the corresponding connectors, and then press the terminal with crimping pliers. After assembling, try to pull back the battery cable to ensure that the terminal is tightly attached in the connector.
  • Page 29 User Manual EBS-B series 6.Insert the positive and negative connectors into the battery power terminals at EBS-P side one cluster by one cluster respectively. When you hear a “click” sound, it means that the connection is well and proper. Power cable connection between EBS-P and the inverter procedure is shown as below: 1.Select an appropriate DC cable.
  • Page 30 User Manual EBS-B series Cable gland Grommet End cap 4.Insert the positive and negative cables into the corresponding connectors, and then press the terminal with crimping pliers. After assembling, try to pull back the battery cable to ensure that the terminal is tightly attached in the connector.
  • Page 31: Communication Cable Connection

    User Manual EBS-B series 7.When pulling out the plug, you need to press the switch button first, and then pull the plug out. 4.2.3 Communication Cable Connection 1.Please insert one side of the communication cable to the "INV" port at EBS-P, and the other side is connected to “BMS”...
  • Page 32 User Manual EBS-B series Set address 1 for the 2nd battery cluster. DIP1 DIP2 Address Set address 2 for the 3rd battery cluster. DIP1 DIP2 Address 3.Turn DIP5 of the battery cluster connected to EBS-P to “ON” position. If the 3rd battery cluster is connected to EBS-P, the address would be:...
  • Page 33: Commissioning

    User Manual EBS-B series Commissioning 5.1 Switch Battery On Step1. Turn the breaker on at the left side of controller module. Step2. Hold down “POWER” button for 3 seconds until the indicator becomes green and flashing, which means that the battery enters self-checking.
  • Page 34: Maintenance And Troubleshooting

    Restart the battery only when the trouble which might affect safety performance is cleared. It is forbidden to random replace internal components. For any maintenance support, please contact Solinteg. Otherwise, Solinteg shall NOTICE not be held liable for any damage caused.
  • Page 35 User Manual EBS-B series Battery module maintenance is shown as below: Frequency Item Solution Working environment Keep away from heat sources and direct sunlight. Every month If there is damage, leakage or deformation, isolate the Visual inspection faulty battery pack, take photos and replace the battery.
  • Page 36: Troubleshooting

    EBS-B series 6.2 Troubleshooting If any battery fault occurs, record the fault information, and switch the battery off accord- ing to the procedures in “5. Commissioning”, and then contact the distributor or Solinteg. Do not handle the fault by yourself. Solution...
  • Page 37: Appendix

    User Manual EBS-B series Appendix 7.1 Technical Parameters 7.1.1 Components of EBS-B Storage System Battery EBS-B2K5-B Nominal Energy (kWh) 2.56 Usable Energy (kWh) Nominal Capacity (Ah) Nominal Voltage (V) 51.2 Voltage Range (V) 44.8~57.6 Max. Charge/Discharge Current (A) 50 / 50...
  • Page 38 User Manual EBS-B series Controller EBS-C Operation Voltage [Vdc] 80 - 750 Max. Charge/Discharge Current [A] 50 / 50 Communication CAN/RS232 Power Connection Type Hard Connection with Positioner & Quick Connector Dimension [W*D*H mm] 650*350*140 Weight [kg] Operating Temperature [℃ ]...
  • Page 39: Energy Storage System

    User Manual EBS-B series 7.1.2 Energy Storage System Storage System EBS-S5K1-B EBS-S7K5-B EBS-S10K-B Nominal Energy (kWh) 5.12 7.68 10.24 Usable Energy (kWh) 4.61 6.91 9.22 Nominal Capacity (Ah) Nominal Voltage (V) 102.4 153.6 204.8 89.6 - 116.8 134.4 - 175.2 179.2 - 233.6...
  • Page 40 User Manual EBS-B series Storage System EBS-S12K-B EBS-S15K-B EBS-S17K-B Nominal Energy (kWh) 12.8 15.36 17.92 Usable Energy (kWh) 11.52 13.82 16.13 Nominal Capacity (Ah) Nominal Voltage (V) 307.2 358.4 Voltage Range (V) 224 - 292 268.8 - 350.4 313.6 - 408.8...
  • Page 41 User Manual EBS-B series Storage System EBS-S20K-B EBS-S23K-B EBS-S25K-B Nominal Energy (kWh) 20.48 23.04 25.6 Usable Energy (kWh) 18.43 20.74 23.04 Nominal Capacity (Ah) Nominal Voltage (V) 409.6 460.8 358.4 - 467.2 403.2 - 525.6 448 - 584 Voltage Range (V)
  • Page 42: Contact Information

    • Serial number of the device • Date of the device • Fault code/name • Brief description of the problem China (HQ) Solinteg Power Co., Ltd. Address: Building H1-1001, No. 6 Jingxian Road, Xinwu District, 214135 Wuxi, Jiangsu Province, China Website: www.solinteg.com Service Mail: service@solinteg.com...
  • Page 43 www.solinteg.com...