SOLINTEG INTEG M MHS-3-8K-30 User Manual

SOLINTEG INTEG M MHS-3-8K-30 User Manual

Hybrid inverter

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INTEG M MHS-3-8K-30 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SOLINTEG INTEG M MHS-3-8K-30

  • Page 5: About This Manual

    The products, services or features purchased are subject to the commercial contracts and terms of Solinteg Power Co., Ltd. All or part of the products, services or features described in this document may not be within the scope of purchase. This document serves only as a guide to use, and all statements, information and recommendations in this document do not constitute any express or implied guarantee.
  • Page 7 User Manual MHS-3~8K series Indicates a hazard with a low level of risk that, if not avoided, could result in minor or moderate injury. CAUTION Indicates a situation that, if not avoided, could result in equipment or property damage, data loss, equipment performance degradation. NOTICE Indicates additional information, emphasized contents or tips that may be helpful, e.g., to help you solve problems or save time.
  • Page 8: Safety Instructions

    2.2 Statement Solinteg Technologies Co., Ltd. has the right not to undertake quality assurance in any of the following circumstances: ① Damages caused by improper transportation.
  • Page 9 User Manual MHS-3~8K series ⑦ Damages caused by unauthorized disassembly, alteration of products or modification of software codes. ⑧ Damages caused by abnormal natural environment (force majeure, such as lightning, earthquake, fire, storm, etc.). ⑨ Any damages caused by the process of installation and operation which don't follow the local standards and regulations.
  • Page 10: Product Description

    It cannot guarantee backup power in all circumstances. NOTICE The applicable grid types for the Solinteg MHS-3~8K series are TN-S, TN-C, TN-C-S and TT. When applied to the TT grid, the voltage of N to PE suggests less than 30V.
  • Page 11: Product Introduction

    3.2 Product Introduction The Solinteg MHS-3~8K series inverter is also known as hybrid inverter or storage inverter, which is mainly used to combine the PV array, lithium battery, loads and power grid to real- ize intelligent power management and dispatching.
  • Page 12 User Manual MHS-3~8K series 3.2.3 Indicator Figure 3-4 Inverter display interface Item Indicator Status Description No power . Quick flashing Inverter entered self-test status. Blue Slow flashing Inverter entered waiting status. Power and Breathe flashing Inverter works normal. Alarm Indicator Low battery warning, the battery power is Orange Breathe flashing...
  • Page 13: Symbols On The Inverter

    User Manual MHS-3~8K series 3.3 Symbols On the Inverter Symbol Description To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment, end-users of electrical and electronic equipment should understand the meaning of the crossed-out wheeled bin symbol.
  • Page 14: Operation Modes

    User Manual MHS-3~8K series 3.4 Operation Modes Solinteg MHS Hybrid inverter has the following basic operation modes and you can config- ure the operation mode as per your preference in the App. General Mode Loads In this working mode, when the power from the PV array is sufficient, PV power will supply the loads, battery, and grid in the order of ...
  • Page 15 User Manual MHS-3~8K series Peak load Shifting (Load Shifting) Loads Set the maximum power Pmax (kVA) contracted with the grid. When the load consumption is less than the Pmax, the PV will charge the battery first, and the grid supplies the load. When the battery is full, PV will supply the load together with the grid, but the battery doesn't.
  • Page 16 User Manual MHS-3~8K series UPS Mode Loads In this working mode, the inverter will use the power from PV or grid to charge the battery until it is fully charged, and as long as the grid is there, the battery won’t discharge. Grid Back-up Loads When the grid fails, power from PV and battery...
  • Page 17 User Manual MHS-3~8K series Economic Mode Loads In this working mode, you can set charge/dis- charge power and time in the App, inverter will use the power from PV or grid (whether to use can be set in the App) to charge the battery in the predetermined period.
  • Page 18 User Manual MHS-3~8K series Off-grid Mode Back-up Loads In the purely off-grid mode, power from PV will supply the back-up loads first and then charge the battery if there's surplus power. No Grid Back-up Load When the power from PV isn’t enough, the battery will discharge to supply back-up loads together with PV.
  • Page 19 For this reason, please conduct a thorough inspection after receiving the device. Contact Solinteg or the transport company in case of any damage or incompleteness, and provide photos to facilitate services. 3.6.1 Packing List The package of the inverter includes the following accessories.
  • Page 20 User Manual MHS-3~8K series User Manual Figure 3-5 Packing list...
  • Page 21 User Manual MHS-3~8K series Item Name and Quantity Note Inverter (1pcs) Wall-mounting bracket (1pcs), Expansion plug set (5pcs), M5 screws (1pcs) On-grid connector set (1pcs) Blue Back-up connector set (1pcs) Black PV terminal (MHS-3~3.6K-30 1 pair / MHS-4.2~8K-30 2 pairs) Black,U-profile pin Battery terminal (1 pair) Blue,O-profile pin...
  • Page 22: Installation

    Installation 4.1 Location The Solinteg MHS-3~8K series inverters are designed with IP65 protection enclosure for in- door and outdoor installations. When selecting an inverter installation location, the following factors should be considered: ① The wall on which the inverters mounted must be able to withstand the weight of the in- verter.
  • Page 23 User Manual MHS-3~8K series 4.1.2 Installation Spacing Reserve enough clearance around the inverter to ensure sufficient space for heat dissipation. 500mm 500mm 300mm 300mm 300mm 500mm 500mm Figure 4-2 Recommended installation spacing 4.1.3 Installation Angle Install the inverter vertically. Never install the inverter horizontally, or at forward/backward tilted, or upside down.
  • Page 24: Mounting The Inverter

    User Manual MHS-3~8K series 4.2 Mounting the Inverter 4.2.1 Wall Bracket Installation Dimensions of wall bracket (mm) Figure 4-4 Dimensions of wall bracket Figure 4-5 Marking hole position using installation bracket ② Use an electrical driller with 10mm diameter bit to drill 5 holes in the wall with 80mm depth. Before drilling, make sure to avoid any buried water tube and electric wires in the wall.
  • Page 25 User Manual MHS-3~8K series Figure 4-6 Fixing the wall bracket 4.2.2 Mounting the Inverter Lift the inverter, hang the back rail on the fixed wall bracket carefully. Secure the inverter with M5 screws. Figure 4-7 Mounting the inverter 4.2.3 External Ground Connection Connect the inverter and ground bar through PE wire to achieve the purpose of grounding protection.
  • Page 26 User Manual MHS-3~8K series Reliable grounding is good for resisting surge voltage shock and improving EMI performance. Inverters must be well-grounded. For a system with only one inverter, just ground the PE cable. NOTICE For a multi-inverter system, all inverters PE wire need to be connected to the same grounding copper bar to ensure equipotential bonding.
  • Page 27: Electrical Connection

    WARNING maintenance. Do not use other brands or other types of terminals other than the terminals in the accessory package. Solinteg has the right to refuse all NOTICE damages caused by the mixed-use of terminals. Moisture and dust can damage the inverter, ensure the cable gland is securely tightened during installation.
  • Page 28: Electrical Wiring Diagram

    AC Breaker Figure 5-1 Electrical wiring diagram *Solinteg Smart Meter consists of ACR10R and RMM. Define the cable connections for the meter based on the actual meter model and refer to Section 5.4. This cable diagram is for reference only.
  • Page 29 11(PE) Figure 5-2 Standard wiring diagram *Solinteg Smart Meter consists of ACR10R and RMM. Define the cable connections for the meter based on the actual meter model and refer to Section 5.4. This cable diagram is for reference only. 12(L)*/13(N)*:Only ACR10R have those parts. 11(PE)* :Only RMM have this part.
  • Page 30 11(PE) Figure 5-3 Australia wiring diagram *Solinteg Smart Meter consists of ACR10R and RMM. Define the cable connections for the meter based on the actual meter model and refer to Section 5.4. This cable diagram is for reference only. 12(L)*/13(N)*:Only ACR10R have those parts. 11(PE)* :Only RMM have this part.
  • Page 31 Max. input (output) current of MHS-3~8kW AC side. The allowable AC cable of wire diameter and cross-sectional area for Solinteg MHS-3~8kW are as shown in the following:...
  • Page 32 User Manual MHS-3~8K series Residual Current Monitoring Device With an integrated universal current-sensitive residual current monitoring unit included, the inverter will disconnect immediately from the mains power once a fault current with a value exceeding the limit is detected. However, if an external residual current device (RCD) is mandatory, the switch must be triggered at a residual current of 300 mA (recommended), or it can be set to other values according to local regulations.
  • Page 33 User Manual MHS-3~8K series The cord end terminals must be locked tightly, and make sure it won’t be loose after a long period of use. WARNING ④ According to the arrow direction push the threaded sleeve to make it connected with the AC terminal head and then rotate the cable gland clockwise to lock it.
  • Page 34 CAUTION 5.3 Monitoring Device Installation Solinteg MHS-3~8K series hybrid inverter supports WIFI, LAN, and 4G communication. Plug the WIFI, LAN, or 4G module into the COM1 port in the bottom of inverter. A slight "click" sound during the installation represents that the assembly is in place.
  • Page 35 The Meter can be installed in the AC combiner box or other places that are unable to be touched by children. Solinteg CT cable with length of 2m, it’s fixed and can’t be extended. The CTs have been connected to the Solinteg Meter when you received them, and you just need to follow the wiring diagram in the Meter to connect CT.
  • Page 36: Communication Connection

    User Manual MHS-3~8K series Meter terminals definition as shown in table below: Definition Function ACR10R L/N connect to grid to detect power grid voltage L-S1 L-S2 To detect the CT current and direction Ground connection Power supplied from grid Reserve RS485 RS485 RS485-2...
  • Page 37 User Manual MHS-3~8K series Definition Function RJ45-1 RS 485 Communicate with Meter RJ45-2 Communicate with BMS Multifunction Relay NO (Normally Open) Reserved Reserved DRM4/8 DRM3/7 DRM2/6 DRED For Australia and New Zealand DRM1/5 RCR For Germany and some other European countries COM D/0 REF D/0 Emergency stop...
  • Page 38 User Manual MHS-3~8K series ② Take out the terminal block. Press Figure 5-14 ② Remove the seal and lead the cable through the cable gland. Figure 5-15 5.5.2 Connect the Meter And BMS Communication Cables The communication between meter/BMS and inverter is RJ45 interface cable.
  • Page 39 User Manual MHS-3~8K series ② Insert one side of the RJ45 plug into the RJ45 port of terminal block. Figure 5-17 ③ Insert another side of the communication cable into the meter RS485 port or BMS CAN port. 5.5.3 Connect Other Cables ①...
  • Page 40 User Manual MHS-3~8K series Figure 5-19 ③ Fix all the wires to the terminal plug according to the assignment and tighten to a torque of 1.2+/-0.1N·m with a screwdriver. Figure 5-20 ④ Pull the wires outward to check whether they are firmly installed. Insert the terminal block into the connector until it snaps into place with an audible click.
  • Page 41 User Manual MHS-3~8K series ⑤ Fasten the swivel nut. ・m 2.5+/-0.1N·m Figure 5-22 5.5.4 Installing the COM Connector ① Remove the waterproof lid from the COM terminal. ② Insert the COM connector into COM terminal on the bottom of the inverter until there is an audible click.
  • Page 42 DRED (Demand Response Enabling Device) interface is special reserved for Australia and New Zealand according to their safety regulation, and Solinteg doesn’t provide the DRED device for the customer.The inverter supports the demand response modes as specified in the stan-...
  • Page 43 User Manual MHS-3~8K series DRED wiring diagram (hybrid inverter) as below: Figure 5-25 DRED mode as shown in table below: Mode Function DRM 0 Operate the disconnection device DRM 1 Do not consume power DRM 2 Do not consume at more than 50% of rated power DRM 3 Do not consume at more than 75% of rated power and source reactive power if capable DRM 4...
  • Page 44 RCR (Ripple Control Receiver) interface is special reserved for Germany and some other Eu- ropean country according to their safety regulation, and Solinteg doesn’t provide the RCR device for the customer. In Germany and some European areas, a ripple control receiver is used to convert a power grid dispatching signal to a dry contact signal.
  • Page 45 Maximum voltage and current at DO dry contact port: 230VAC 1A/ 30VDC 1A. NOTICE For more installation and setup information, please contact Solinteg. NOTE Load Control Breaker Contactor...
  • Page 46 The AC contactor should be placed between the inverter and the loads. Do not connect the load to DO port directly. The contactor is not supplied by the Solinteg. Connect the load to the DO port of the inverter directly if the load is designed with a DI port.
  • Page 47 The back-up side cannot be connected on- connected to and generator directly. grid side or grid. For advanced applications, please contact our after-sales department. Figure 5-27 For more installation and setup information about parallel system, please contact Solinteg . NOTE...
  • Page 48 5.5.10 Emergency stop Solinteg MHS-3~8kW hybrid inverter comes standard with Emergency stop function, and you can use this function by connecting an external switch into the Emergency stop inter- face if it requires in the installation place. The external switch doesn't include in our acces- sory box.
  • Page 49 User Manual MHS-3~8K series 5.6.1 PV Side Requirements System Layout of Units with external DC Switch ① Local standards or codes may require PV systems that fit with an external DC switch on the DC side. The DC switch must be able to safely disconnect the open-circuit voltage of the PV array plus a safety reserve of 20%.
  • Page 50 User Manual MHS-3~8K series Please distinguish U-profile pin (PV terminal) and O-profile pin (Battery terminal). Recommended for crimping U-profile pin with "Phoenix CRIMPFOX-RC 10 - NOTE Indent Crimping pliers" ① Peel off the DC cable insulation sleeve for 7 mm. Figure 5-30 ②...
  • Page 51 User Manual MHS-3~8K series Open-end Wrench Figure 5-33 5.6.3 Installing the PV Connector ① Rotate the DC switch to “OFF” position. Figure 5-34 ② Check the cable connection of the PV string for polarity correctness and ensure that the open circuit voltage in any case does not exceed the inverter input limit of 600V.PV Max. In- put voltage is 550V without battery, or 500V with battery, otherwise inverter will be waiting.
  • Page 52 User Manual MHS-3~8K series ③ Insert the positive and negative connectors into the inverter DC input terminals respec- tively, a click sound should be heard if the terminals are well connected. Figure 5-36 ④ Seal the unused PV terminals with the terminal caps.
  • Page 53 If the conductor core of the battery cable is too small, which may cause poor contact between the terminal and the cable, please use the cable specified in the above table, or contact Solinteg to purchase terminals CAUTION of other specifications.
  • Page 54 User Manual MHS-3~8K series Please distinguish U-profile pin (PV terminal) and O-profile pin (Battery terminal). Recommended for crimping O-profile pin with "Phoenix CRIMPFOX 10S - Square NOTE Crimping pliers" 10mm 10mm 10mm 10mm Figure 5-38 ③ Insert the battery cable through the battery connector nut into the metal terminal and press the terminal with a professional crimping plier (pull back the cable with some power to check if the terminal is well connected to the cable).
  • Page 55 User Manual MHS-3~8K series ① Before making the battery connector, please make sure the polarity of the cable is correct. ② Use a multimeter to measure the voltage of the battery pack and make WARNING sure the voltage is within the inverter limitation and the polarity is correct. ⑥...
  • Page 56 "8.2 Cloud monitoring App and 8.3 Local configuration App". ② Register an account on the Cloud monitoring App. If you have got the account and password from the distributor/installer or Solinteg, skip this step. 6.2 Inspection Before Commissioning Check the following items before starting the inverter: ①...
  • Page 57 User Manual MHS-3~8K series ⑥ After the inverter is started, please refer to the [QUICK USE GUIDE] which is attached to the access to configure the inverter. If the inverter does not work properly, check the country code and battery ID Settings. ①...
  • Page 58: Operation

    User Manual MHS-3~8K series Operation When the inverter is turned on, the following interfaces will be displayed on the OLED display, and the OLED display allows the user to check various operation information and to modify the settings of the inverter. If the parameter is a number short press to change the number, long press to confirm the number and jump to the next number.
  • Page 59: General Setting

    User Manual MHS-3~8K series 7.2 General Setting General Settings FM Version V1.xx.xx.xx.xx Check code System Info V1.00 xxxxxxxxxxxxxxx V1.xx.xx.xx.xx xxxxxx 2022-05-30 10:05:05 2022-05-30 10:05:05 2022-05-30 10:05:05 Fault Info Fault 1 Fault 2 Fault N RSSI <General> <General> <General> <General> DHCP Set DHCP Set IP Addr IP Addr...
  • Page 60 User Manual MHS-3~8K series Inverter Display Abbreviation and Complete Name Reference Table Abbreviation Complete Name System Info System information FM Version Firmware version Series number Fault Info Fault information RSSI Received signal strength indicator DHCP Set Enable or disable DHCP functionality IP Addr If DHCP is turned off, set the static IP address Gateway Addr...
  • Page 61 User Manual MHS-3~8K series 7.3 Advanced Setting *Please contact Solinteg service team for password.
  • Page 62 User Manual MHS-3~8K series *Please contact Solinteg service team for password.
  • Page 63 User Manual MHS-3~8K series Inverter Display Abbreviation and Complete Name Reference Table Abbreviation Complete Name Safety Set Select the code that meet local regulatory requirements Battery_ID Set Select the battery model Work Mode Current work mode / work mode setting Export Limit On-grid export limit function switch Feed in Grid...
  • Page 64 User Manual MHS-3~8K series Abbreviation Complete Name If turned it on, the battery will be automatically charged to calibrate the battery SOC. SOC Reset After the battery is charged, this function will be turned off automatically MPPT Parallel If MPPT is connected in parallel, enable this function. Select the maximum AC output power.
  • Page 65 User Manual MHS-3~8K series Connect the AC cable, auto test will start after the inverter connected to the grid, see the operation steps below:...
  • Page 66: Reactive Power

    This mode can be enabled via configuration software. It is enabled by default in some regions, such as AU, DE market. For information on how to change default setpoints please contact Solinteg Technical Support at service@solinteg.com. Descriptions of reactive power regulation mode:...
  • Page 67 User Manual MHS-3~8K series 7.6.3 “Qt” Mode In the Qt mode, system rated reactive power is fixed, and the system injects reactive power according to the delivered reactive power ratio. The setting range of the reactive power ratio is -60%~60%, corresponding to the ranges of inductive and capacitive reactive power regulation respectively.
  • Page 68 User Manual MHS-3~8K series 7.6.5 “Q(U)” Mode The reactive power output of the inverter will vary in response to the grid voltage. “Q(U)” Mode Parameter Descriptions: Parameter Explanation Range QU_V1 Grid voltage limit at P1 on the Q(U) mode curve 80% ~ 100% QU_Q1 Value of Q/Sn at P1 on the Q (U) mode curve...
  • Page 69: Monitoring Device

    User Manual MHS-3~8K series Monitoring 8.1 Monitoring Device Indicator Button Figure 8-1 Monitoring device display interface Indicator Status Description Connection abnormal Always On Communicate with the server normally The monitoring device is not connected to the router or is not connected to the base Slow flashing station.
  • Page 70 8.2 Cloud monitoring App Solinteg inverter provides a monitoring port that can collect and transmit data from the inverter to Solinteg monitoring platform via an external monitoring device. Please refer to the product nameplate on side of enclosure to get the monitoring application. If download issues exist, contact your dealer or Solinteg technical support.
  • Page 71: Troubleshooting

    Troubleshooting 9.1 Error Message Solinteg MHS-3~8K series hybrid inverter is designed in accordance with grid operation standards, and conform to the requirements of safety and EMC. The inverter had passed a series of rigorous tests to ensure it runs sustainably and reliably before shipment.
  • Page 72 User Manual MHS-3~8K series Error Message Description Solution 1. Check whether PV panels, cables, and con- nectors are waterlogged or damaged. Inverter detects that DC side's insula- ISO Over Lim- 2. Use a megger to measure ground resistance tion impedance to the ground is too itation on the DC sidel, and the measured value should low.
  • Page 73 User Manual MHS-3~8K series Error Message Description Solution Internal storage got abnomal. Caused 1. Restart the inverter. E2 Fault by a strong external magnetic field etc. 2. Seek help from the installer or manufacture. G FC I D e v i c e 1.
  • Page 74 User Manual MHS-3~8K series Error Message Description Solution Turn off inverter and remove the back-up connec- Abnormal voltage exists on the back- Backup OV tor. Use a multimeter to measure whether there is up side voltage existing on the back-up connector. Check whether the battery voltage or PV input Bus Volt Low Abnormal power schedduling...
  • Page 75 User Manual MHS-3~8K series Error Message Description Solution Internal communication got failed. 1. Restart the inverter. SCI Fault Caused by a strong external mag- 2. Seek for help from the installer or manufacture. netic field etc. Internal storage anomaly. Caused by 1.
  • Page 76 CAUTION person away while performing electrical connection and maintenance. Any Arbitrary replacement of internal components is forbidden. Please seek help from Solinteg for maintenance support. Otherwise, we NOTICE will not take any responsibility. Please remember not to do the self-maintenance before being familiar with the proper instruction of the whole process.
  • Page 77 User Manual MHS-3~8K series Items Methods Period Check dust or foreign matter on the heat-sink, air System clean Once 6-12 months inlet and outlet. Electrical Check whether the cables are in good connection. Once 6-12 months connection Check whether all the terminals and ports are Sealing properly sealed.
  • Page 78: Technical Parameters

    User Manual MHS-3~8K series Appendix 10.1 Technical Parameters Model MHS-3K-30 MHS-3.6K-30 PV Input Start-up voltage (V) Max. DC input voltage (V)* 600* 600* Rated DC input voltage (V) MPPT voltage range (V)* 100-550* 100-550* No. of MPP trackers No. of DC inputs per MPPT Max.
  • Page 79 User Manual MHS-3~8K series Model MHS-3K-30 MHS-3.6K-30 Grid Side Max. output current (A) 15.0 18.0 Max. input current (A) 26.1 31.3 Power factor 0.8 leading …0.8 lagging Max. total harmonic distortion <3% @Rated output power <0.5%In <0.5%In Back-up Side Rated output power (kW) 3.96 Max.
  • Page 80 User Manual MHS-3~8K series Model MHS-3K-30 MHS-3.6K-30 Protection AC over-voltage protection Integrated Overload protection Integrated AC short-circuit protection Integrated General Data Over voltage category PV: Ⅱ ; Main: Ⅲ Dimensions (mm) 534*418*210 (W*H*D) Weight (KG) Protection degree IP65 IP65 Standby self-consumption (W) <15 <15 Topology...
  • Page 81 User Manual MHS-3~8K series Model MHS-4.2K-30 MHS-5K-30 PV Input Start-up voltage (V) Max. DC input voltage (V)* 600* 600* Rated DC input voltage (V) MPPT voltage range (V)* 100-550* 100-550* No. of MPP trackers No. of DC inputs per MPPT Max.
  • Page 82 User Manual MHS-3~8K series Model MHS-4.2K-30 MHS-5K-30 Grid Side Max. total harmonic distortion <3% @Rated output power <0.5%In <0.5%In Back-up Side Rated output power (kW) Max. output power (kW) Rated output apparent power (kVA) Max. output apparent power (kVA) Rated output current (A) 18.3 21.7 Max.
  • Page 83 User Manual MHS-3~8K series Model MHS-4.2K-30 MHS-5K-30 General Data Over voltage category PV: Ⅱ ; Main: Ⅲ Dimensions (mm) 534*418*210 (W*H*D) Weight (KG) Protection degree IP65 IP65 Standby self-consumption (W) <15 <15 Topology Transformerless Operating Temperature Range (°C) -30~60 -30~60 Relative Humidity (%) 0~100 0~100...
  • Page 84 User Manual MHS-3~8K series Model MHS-6K-30 MHS-8K-30 PV Input Start-up voltage (V) Max. DC input voltage (V)* 600* 600* Rated DC input voltage (V) MPPT voltage range (V)* 100-550* 100-550* No. of MPP trackers No. of DC inputs per MPPT Max.
  • Page 85 User Manual MHS-3~8K series Model MHS-6K-30 MHS-8K-30 Grid Side Max. total harmonic distortion <3% @Rated output power <0.5%In <0.5%In Back-up Side Rated output power (kW) Max. output power (kW) Rated output apparent power (kVA) Max. output apparent power (kVA) Rated output current (A) 26.1 36.3 Max.
  • Page 86 User Manual MHS-3~8K series Model MHS-6K-30 MHS-8K-30 General Data Over voltage category PV: Ⅱ ; Main: Ⅲ Dimensions (mm) 534*418*210 (W*H*D) Weight (KG) Protection degree IP65 IP65 Standby self-consumption (W) <15 <15 Topology Transformerless Operating Temperature Range (°C) -30~60 -30~60 Relative Humidity (%) 0~100 0~100...
  • Page 87 • Serial number of the device • Date of the device • Fault code/name • Brief description of the problem China (HQ) Solinteg Power Co., Ltd. Address: Building H1-1001, No. 6 Jingxian Road, Xinwu District, 214135 Wuxi, Jiangsu Province, China Website: www.solinteg.com Service Mail: service@solinteg.com...
  • Page 89 www.solinteg.com...

Table of Contents