Contents Introduction..............2 Troubleshooting.............. 8 Safety................4 Error codes..............10 Operation................ 6 Transportation, storage and disposal......11 Maintenance..............7 Technical data.............. 13 Introduction Product overview 1. Operator's manual 18. Rating plate 2. Air outlet vents Product description 3. OFF button 4. ON button The product is an adjustable frequency converter that is used to supply electric concrete vibrators with adjustable 5.
Symbols on the product Note: Other symbols/decals on the product refer to special certification requirements for some markets. WARNING: This product can be dangerous and cause serious injury or Rating plate death to the operator or others. Be careful and use the product correctly. 12 13 Read the operator's manual carefully and make sure that you understand the...
Safety Safety definitions • This product produces an electromagnetic field during operation. This field can under some Warnings, cautions and notes are used to point out circumstances interfere with active or passive specially important parts of the manual. medical implants. To decrease the risk of serious injury or death, we recommend persons with medical WARNING: implants to speak to their physician and the medical...
Page 5
• Do not connect a damaged power cord to the correctly, speak to your Husqvarna servicing dealer. product. • Do not make modifications to safety devices.
Clean the product to remove dangerous material product regularly. The product must be checked by before you do the maintenance. a Husqvarna service agent at least once each 6 months and repaired if it is necessary. • Disconnect the product from the power source and wait 5 minutes to let the electric circuit discharge •...
6. Adjust the output frequency with the frequency Type No of output variation knob. AX 48 7. Set the power switch (MPCB) for the power outlet of the connected concrete vibrator to the ON position. AX 56 8. Push the ON button on the connected concrete AX 65 vibrator if there are pokers.
There is no power in the power outlet. agent. The product does not start. Let a Husqvarna service agent replace the The power cord is damaged. power cord. Error codes on page 10 . There is an error on the display.
Page 9
The outlet switch (MPCB) trips. uct. Speak to an approved Husqvarna service agent. Let an electrician do a check of the input voltage. The input voltage must be between The mains breaker (MCB) trips.
Surge current or concrete vibrator operates correctly Surge current or short circuit. short circuit. but the error code still shows, speak to an approved Husqvarna service agent. There is an internal error of the pow- Speak to an approved Husqvarna er module.
The soft start resistor value has changed. There is an error There is a loss in the input phase Speak to an approved Husqvarna in the soft starter. when the product starts. service agent. The main circuit capacitor is dam- aged.
• Attach the lifting equipment at the lifting point of the safety frame. A label on the product identifies the correct position. WARNING: Do not use metal hooks, chains or other lifting equipment with rough edges that can cause damage to the lifting eye. Storage •...
Technical data Technical data Technical data Weight, kg/lb 81/179 Height, mm/in. 380/15 Lengt, mm/in. 645/25.4 Width mm/in. 265/10.4 Input voltage, V Phases Input frequency, Hz Input current, A Output voltage Output frequency, Hz 100–200 Output power, kVA Output current, A Maximum output current on each outlet, A Wheels Number of outlets...
Need help?
Do you have a question about the CF 85 AS and is the answer not in the manual?
Questions and answers