Table of Contents

Advertisement

Quick Links

MTS9000A Telecom Power (Russia, Veon,
MTS9304A-HD10A1, MTS9304A-AX10A1,
MTS9514A-GX1401)
User Manual
Issue
01
Date
2020-01-17
HUAWEI TECHNOLOGIES CO., LTD.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MTS9000A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Huawei MTS9000A

  • Page 1 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual Issue Date 2020-01-17 HUAWEI TECHNOLOGIES CO., LTD.
  • Page 2 Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS"...
  • Page 3: About This Document

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual About This Document About This Document Purpose This document describes the product features, components, and maintenance methods. Figures provided in this document are for reference only. Intended Audience This document is intended for: ...
  • Page 4: Change History

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual About This Document Change History Changes between document issues are cumulative. The latest document issue contains all the changes made in earlier issues. Issue 01 (2020-01-17) This is the first official release.
  • Page 5: Table Of Contents

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual Contents Contents About This Document ........................ii 1 Safety Precautions ......................... 1 1.1 General Safety ................................1 1.2 Personnel Requirements ............................... 5 1.3 Electrical Safety ................................5 1.4 Installation Environment Requirements ........................7 1.5 Mechanical Safety ................................
  • Page 6 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual Contents 3.9 AH1500H ..................................55 3.10 AC Heater HAU03A ..............................56 3.11 DC Heater HAU02D ..............................57 3.12 TCUC ..................................58 3.13 Sensors ..................................59 3.13.1 Digital Temperature and Humidity Sensor ......................59 3.13.2 Smoke Sensor ................................
  • Page 7 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual Contents 4.3.17 Replacing a Door Status Sensor ..........................92 4.3.18 Replacing a Battery Temperature Sensor ....................... 93 A Technical Specifications ......................95 A.1 Environmental Specifications ............................ 95 A.2 Electrical Specifications............................. 96 A.3 EMC Specifications ..............................
  • Page 8: Safety Precautions

    The "NOTICE", "CAUTION", "WARNING", and "DANGER" statements in this document do not cover all the safety instructions. They are only supplements to the safety instructions. Huawei will not be liable for any consequence caused by the violation of general safety requirements or design, production, and usage safety standards.
  • Page 9 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 1 Safety Precautions  When installing, operating, or maintaining the equipment, wear dedicated protective gears such as insulation gloves, goggles, and safety clothing, helmet, and shoes, as shown in the following figure.
  • Page 10: Personal Safety

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 1 Safety Precautions  Before installing, operating, or maintaining a cabinet, clean up any water, ice, snow, or other sundries on the top of the cabinet to prevent sundries from falling into the cabinet when you open the cabinet door.
  • Page 11 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 1 Safety Precautions Symbol Conventions To ensure personal and equipment safety, observe all the safety instructions marked on the equipment when installing, operating, and maintaining the equipment. Symbol Description Indicates a part exposed to high voltage. This symbol warns operators that both direct and indirect contact with the power grid is fatal.
  • Page 12: Personnel Requirements

    1.2 Personnel Requirements  Personnel who plan to install or maintain Huawei equipment must receive thorough training, understand all necessary safety precautions, and be able to correctly perform all operations. ...
  • Page 13 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 1 Safety Precautions  The power system is energized by power sources with hazardous voltage. Direct or indirect contact (through damp objects) with the power sources may result in electric shock.
  • Page 14: Installation Environment Requirements

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 1 Safety Precautions 1.4 Installation Environment Requirements  To prevent fire due to high temperature, ensure that the ventilation vents or heat dissipation system are not blocked when the equipment is running.
  • Page 15: Mechanical Safety

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 1 Safety Precautions  Set a restricted area and eye-catching signs for working at heights to warn away irrelevant personnel.  Carry the operation machinery and tools properly to prevent them from falling off and causing injuries.
  • Page 16: Using Ladders

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 1 Safety Precautions  Do not drag steel ropes and hoisting tools or bump hoisted objects against hard objects during hoisting. Using Ladders  Use wooden or fiberglass ladders when you need to perform live working at heights.
  • Page 17: Drilling Holes

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 1 Safety Precautions  Keep your body steady.  Do not climb higher than the fourth rung of the ladder from the top.  To climb onto a roof, ensure that the ladder top is at least one meter higher than the roof line, as shown in the following figure.
  • Page 18: Battery Safety

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 1 Safety Precautions  Move or lift the equipment by holding its handles or lower edges. Do not hold the handles of modules (such as power supply units, fans, and boards) that are installed in the equipment because they cannot support the weight of the equipment.
  • Page 19: Battery Installation

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 1 Safety Precautions  Do not use a damaged battery.  To prevent injuries or explosion, do not allow children or pets to swallow or bite a battery.  If batteries experience discoloration, deformation, abnormal heating, or other abnormalities during working, charging, or storage, stop using the batteries and replace them with new ones.
  • Page 20: Battery Leakage

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 1 Safety Precautions  Do not use unsealed lead-acid batteries.  To prevent fire or corrosion, ensure that flammable gas (such as hydrogen) is properly exhausted for lead-acid batteries. Lead-acid batteries emit flammable gas when used. Ensure that batteries are kept in a well-ventilated area and take preventive measures against fire.
  • Page 21 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 1 Safety Precautions  When maintenance is complete, return the waste lithium battery to the maintenance office. Issue 01 (2020-01-17) Copyright © Huawei Technologies Co., Ltd.
  • Page 22: Product Overview

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 2 Product Overview Product Overview 2.1 Introduction to the MTS The multiple telecommunication system (MTS) is a solution that provides an outdoor operating environment, security management, and monitoring network for wireless telecom sites.
  • Page 23: Cabinet Description

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 2 Product Overview 2.2 Cabinet Description 2.2.1 MTS9304A-HD10A1 (H2 power cabinet) Figure 2-1 Appearance Table 2-1 Cabinet description Item Description External dimensions 1000 mm x 650 mm x 650 mm (including the 100 mm high base,...
  • Page 24 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 2 Product Overview  Class B environments refer to indoor environments in which the ambient temperature and humidity are not controlled and outdoor environments (with simple shielding measures such as awning installation) where the humidity can reach 100%.
  • Page 25: Mts9304A-Ax10A1 (A2 Power Cabinet)

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 2 Product Overview 2.2.2 MTS9304A-AX10A1 (A2 power cabinet) Figure 2-3 Appearance Table 2-2 Cabinet description Item Description External dimensions 1000 mm x 650 mm x 650 mm (including the 100 mm high base,...
  • Page 26 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 2 Product Overview Figure 2-4 Interior (1) Smoke sensor (2) Battery power (3) Door status sensor distribution box (4) ACDB (5) Ground bar (6) Digital temperature and humidity sensor (Digital T/H sensor)
  • Page 27: Mts9514A-Gx1401 (A3 Power Cabinet)

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 2 Product Overview 2.2.3 MTS9514A-GX1401 (A3 power cabinet) Figure 2-5 Appearance Table 2-3 Cabinet description Item Description External dimensions 1410 mm x 815 mm x 735 mm (including the 150 mm high base,...
  • Page 28 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 2 Product Overview Figure 2-6 Interior (3) Digital T/H (1) Air conditioner AH1500H (2) ACDB sensor (4) Ground bar (5) AC heater (6) Smoke sensor (7) Door status sensor (8) Battery power distribution...
  • Page 29: Mts9300A-Hx10A2 (H1 Equipment Cabinet)

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 2 Product Overview 2.2.4 MTS9300A-HX10A2 (H1 equipment cabinet) Figure 2-7 Appearance Table 2-4 Cabinet specifications Item Specifications External dimensions (H x 1000 mm x 650 mm x 650 mm (including the 100 mm high...
  • Page 30 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 2 Product Overview Figure 2-8 Interior (1) Smoke sensor (2) Door status sensor (3) ACDB (4) Ground bar (5) AC heater (6) Digital T/H sensor (7) Space for customer equipment...
  • Page 31: Mts9300A-Ax10A1 (A1 Equipment Cabinet)

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 2 Product Overview 2.2.5 MTS9300A-AX10A1 (A1 equipment cabinet) Figure 2-9 Appearance Table 2-5 Cabinet specifications Item Specifications External dimensions (H x 1000 mm x 650 mm x 650 mm (including the 100 mm high...
  • Page 32 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 2 Product Overview Figure 2-10 Interior (1) Smoke sensor (2) Door status sensor (3) ACDB (4) Ground bar (5) AC heater (6) Digital T/H sensor (7) Air conditioner (8) Space for customer...
  • Page 33: Mts9300A-Xa10A4 (A Battery Cabinet)

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 2 Product Overview 2.2.6 MTS9300A-XA10A4 (A battery cabinet) Figure 2-11 Appearance Table 2-6 Cabinet specifications Item Specifications External dimensions (H x 1000 mm x 650 mm x 650 mm (including the 100 mm high...
  • Page 34 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 2 Product Overview Figure 2-12 Interior (1) Smoke sensor (2) Door status sensor (3) Space for batteries (4) Digital T/H sensor (5) AC heater (6) Ground bar (7) Air conditioner PC300D...
  • Page 35: Deu04D-H120A3 (Deu Equipment Cabinet)

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 2 Product Overview 2.2.7 DEU04D-H120A3 (DEU equipment cabinet) Figure 2-13 Appearance Table 2-7 Cabinet description Item Description External dimensions 660 mm x 340 mm x 540 mm (H x W x D) ≤...
  • Page 36 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 2 Product Overview Figure 2-14 Internal structure (1) DC output circuit (2) Space for customer (3) RTN+ output breakers equipment terminals (4) DC hearter HAU02D (5) Door status sensor (6) Cable bags...
  • Page 37 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 2 Product Overview Figure 2-15 Side view of a cabinet (1) Internal circulation fan (2) Heat exchanger core (3) External circulation fan Issue 01 (2020-01-17) Copyright © Huawei Technologies Co., Ltd.
  • Page 38: Components

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Components 3.1 Power Distribution Unit 3.1.1 Power Subrack Figure 3-1 ETP48400-C3B1 appearance (1) AC input module (2) Space for rectifiers (3) UIM05B1 (4) Reserved slot for communications (5) Battery wiring...
  • Page 39: Ac Power Distribution Box (Acdb)

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Item Specifications  AC surge protection: nominal surge discharge current: 30 Surge protection kA (8/20 µs)  DC surge protection: 10 kA (8/20 µs) in differential mode, 20 kA (8/20 µs) in common mode ...
  • Page 40 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components ACDB (A2 power cabinet) Figure 3-3 Appearance (1) Maintenance socket (2) AC output N terminals (3) RCD (for maintenance socket) (4) AC output circuit breakers Table 3-3 Specifications...
  • Page 41 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Table 3-4 Specifications Item Specifications AC output Three 1-pole 10 A circuit breakers, one 1-pole 20 A circuit breaker, one maintenance socket, and one 10 A protection circuit breaker...
  • Page 42: Intelligent Power Distribution Unit

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components ACDB (A1 equipment cabinet) Figure 3-6 Appearance (1) Maintenance socket and RCD (2) AC output circuit breakers and (3) AC terminals (4) AC input circuit breakers and (5) PE bar...
  • Page 43: Communications Parameter

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Figure 3-8 DMU02C1 panel (1) Run indicator (2) Alarm indicator (3) RS485 communications ports Table 3-7 Indicator description Name Color Status Description Run indicator Green The DMU is faulty or has no DC input.
  • Page 44 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Table 3-9 Pin definitions for the RS485 port Signal Description Transmits data over RS485 Receives data over RS485 – 3, 6, 7, 8 Figure 3-10 DIP switch ...
  • Page 45: Battery Power Distribution Box

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Item Specifications Dimensions (H x W x D) 43.6 mm x 482.6 mm x 255 mm ≤ 10 kg Weight Installation mode Installed in a 19-inch rack Cabling mode...
  • Page 46: Psu (Dpu40D-N06A3)

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components 3.2 PSU (DPU40D-N06A3) Functions The PSU integrates power rectification, distribution, and monitoring. It converts AC or HVDC power into stable 48 V DC power, generates fault alarms, and reports monitoring data to the upstream network management system (NMS) in real time.
  • Page 47: Power Ports

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Indicator Color Status Description Start / Self-check / Load (instantaneous status Steady on during startup or upgrade) Blinking at long The PSU communicating with the host intervals (0.5 Hz)
  • Page 48: Communications Ports

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Port Fuse Specifications Function 1 × 40 A quick-connector ( excluding Battery port; connects to the lithium battery. the fuse) Communications Ports Table 3-14 Communications port description Communications...
  • Page 49 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Signal Name Description CANL CAN data transmission and reception L Figure 3-15 COM_ALM port pins Table 3-16 COM_ALM port pin definitions Signal Name Description ALM1+ Associated with the AC failure alarm; OC door output;...
  • Page 50: Lithium Battery (Dbu20B-N12A3)

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components 3.3 Lithium Battery (DBU20B-N12A3) Functions The lithium battery supplies backup power to communications equipment when the PSU has no power input, thereby ensuring reliable power supply for service operation.
  • Page 51 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Name Color Status Meaning Blinking The lithium battery is communicating properly with slowly (0.5 monitoring equipment Blinking fast The lithium battery fails to communicate with (4 Hz) monitoring equipment...
  • Page 52: Rectifier

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Communications Ports Table 3-19 Communications port description Communications Communications Protocol Function Port COM_IN, COM_OUT CAN2.0 Communicates with a PSU or with a cascaded lithium battery. Figure 3-18 COM_IN/COM_OUT port pins...
  • Page 53 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Figure 3-19 Rectifier (1) Power indicator (2) Alarm indicator (3) Fault indicator (4) Locking latch (5) Handle Table 3-21 Rectifier indicator description Indicator Color Status Description Power indicator...
  • Page 54: Smu02C

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Indicator Color Status Description overvoltage. The rectifier has no output due to an internal fault. 3.5 SMU02C Figure 3-20 SMU02C appearance (1) SD card slot (2) Run indicator...
  • Page 55: Sd Card Slot

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Name Color Status Description Minor alarm Yellow No minor or warning alarm is generated. indicator Steady on A minor or warning alarm is generated. Major alarm No critical or major alarm is generated.
  • Page 56: Communications Port

    MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Using WiFi modules provided by another vendor may cause data loss or function exception. Consequences arising from this will not be borne by Huawei. Communications Ports Table 3-24 Communications port description Communications Communications Parameter...
  • Page 57 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Table 3-26 Pin definitions for the RS485/RS232 port Signal Description Transmits data over RS485 Receives data over RS485 RX232 Receives data over RS232 TX232 Transmits data over RS232...
  • Page 58: User Interface Module Uim05B1

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components 3.6 User Interface Module UIM05B1 Figure 3-22 Panel (1) Dry contact and sensor (2) COM communications (3) Battery temperature sensor ports port port (4) Door status sensor port...
  • Page 59: Pc300D

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Table 3-28 COM port pin definitions Signal Description RS485_RX+ RS485 data, positive RS485_RX- RS485 data, negative 12 V Power supply RS485_TX+ RS485 data, positive RS485_TX- RS485 data, negative Ground –...
  • Page 60: Dc Air Conditioner Pc1000D-1

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Item Specifications Heating capacity 300 W –48 V DC (–44 V DC to –57 V DC) Input voltage –40° C to +55° C Operating temperature Storage temperature -40° C to +70° C Alarm reporting Reports alarms over dry contacts.
  • Page 61: Specification

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Table 3-30 PC1000D-1 specifications Specification Value –48 V DC Rated voltage ≥ 11 A Circuit breaker capacity Rated cooling capacity 1250 W Rated cooling power 345 W –15° C to +55° C...
  • Page 62: Ah1500H

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components 3.9 AH1500H Figure 3-27 Appearance (1) Air return vent (2) Air supply vent (4) Display panel (4) Wiring port Table 3-31 Specifications Item Specifications Cooling capacity (L35/L35) 1500 W...
  • Page 63: Ac Heater Hau03A

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Item Specifications Altitude < 4000 m Relative humidity 5%–95% RH GR487, acoustic pressure level: ≤ 65dB(A) at 1.5 m Noise 3.10 AC Heater HAU03A A heater assembly unit (HAU) is adopted to ensure a proper operating temperature for the equipment inside the cabinet.
  • Page 64: Dc Heater Hau02D

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Table 3-33 Heater specifications Item Specifications Input voltage 220 V AC single-phase or 110 V AC dual-live wire Voltage frequency Rated frequency: 50 Hz/60 Hz –40° C to +65° C...
  • Page 65: Tcuc

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Item Specifications –40° C to +65° C Operating temperature range Startup temperature 5± 3° C Shutdown temperature 15± 3° C Operating humidity range 5–95% RH Altitude 0–4000 m.
  • Page 66: Status Description

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components (13) Water sensor port (14) Internal circulation fan (15) TEC port ports Table 3-35 Indicator description Silk Screen Color Status Description Green Steady on The board has a normal power supply, but no program is running.
  • Page 67: Dip Switch

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Figure 3-32 Appearance 2 DIP Switch The following figures show the DIP switch on a digital temperature and humidity sensor. The following table describes the DIP switch settings.
  • Page 68: Smoke Sensor

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components 3.13.2 Smoke Sensor There are two types of smoke sensors with compatible mounting ports. Figure 3-35 and Figure 3-36 show these two types of smoke sensors. Figure 3-35 Smoke sensor 1...
  • Page 69: Door Status Sensor

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components Figure 3-37 Water sensor Technical Specifications Table 3-37 Water sensor specifications Categor Item Specifications –40° C to +80° C Environ Operating temperature ment –40° C to +80° C...
  • Page 70: Battery Temperature Sensor

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 3 Components 3.13.5 Battery Temperature Sensor Figure 3-39 Battery temperature sensor Issue 01 (2020-01-17) Copyright © Huawei Technologies Co., Ltd.
  • Page 71: Maintenance

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Maintenance This section does not describe the maintenance of the PSU (DPU40D-N06A3) and lithium battery (DBU20B-N12A3). For details about the maintenance of the DPU40D-N06A3 and DBU20B-N12A3, see DPU40D-N06A3, DBU20B-N12A3, and DBU50B-N12A1 Distributed Power System User Manual at http://support.huawei.com.
  • Page 72: Ac And Dc Power Distribution

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Maintenance Item If... Then... Check whether the front The front or rear of Remove the blockage or and rear of rectifiers are rectifiers is blocked or clean up the dust.
  • Page 73: Rectifier

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Maintenance Item If... Then... open-phase. contact, 2. Provide the short-circuited, or open-phase data to the damaged. power supplier.  The mains supply has failed. Check whether a DC ...
  • Page 74: Smu

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Maintenance Item If... Then...  AC input is required. over/undervoltage protection is triggered.  The rectifier is in hibernation. 1. Check that the rectifier Blinking: communications cable ...
  • Page 75: Parameters On The Smu

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Maintenance Item If... Then... system (NMS).  Networking 2. Check that networking parameters are not parameter settings are correctly set. correct. 4.1.5 Parameters on the SMU Table 4-5 SMU parameter maintenance...
  • Page 76: Cables

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance 4.1.6 Cables Table 4-6 Cable maintenance Maintenance Item If... Then... Check whether signal Cables are not properly Bind signal cables and cables and power cables installed. power cables separately.
  • Page 77: Identifying Ssu Faults

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance  The slot connector and SMU are normal, but the Alarm indicator (yellow) still blinks after the rectifier is reinstalled.  The AC input and SMU are normal, but the SMU cannot control the rectifier.
  • Page 78: Replacing A Rectifier

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance  Ensure that loads are supplied with power when replacing major components. For example, keep the switches for primary loads in the ON position, and do not turn off the battery switch and AC input switch at the same time.
  • Page 79: Follow-Up Procedure

    User Manual 4 Maintenance Figure 4-2 Installing a rectifier Step 7 Take off protective gloves. ----End Follow-up Procedure Pack the removed component, and return it to Huawei local warehouse. 4.3.2 Replacing a Circuit Breaker Prerequisites  Tools are available. ...
  • Page 80: Replacing An Ac Input Module

    Step 6 Switch on the circuit breaker. ----End Follow-up Procedure Pack the removed component and send it to the local Huawei warehouse. 4.3.3 Replacing an AC Input Module Prerequisites The required tools are available and the new AC input module is intact.
  • Page 81: Replacing An Smu02C

    Record the software version of the old SMU. If the old SMU is damaged and cannot be viewed, send the barcodes of the old SMU and the cabinet to Huawei service personnel for query. Step 2 Remove the communications cable from the SMU02C panel and record the cable information.
  • Page 82: Replacing A Uim05B1

    Step 10 Reconnect the communications cable to the SMU02C panel based on the recorded cable information. ----End Follow-up Procedure Pack the removed component and have it sent to the local Huawei warehouse. 4.3.5 Replacing a UIM05B1 Prerequisites  The ESD wrist strap, ESD gloves, ESD box or bag, and toolbox are available.
  • Page 83: Replacing A Dmu02C1

    Step 4 Install the new UIM05B1. Step 5 Install the cables based on the recorded information. ----End Follow-up Procedure Pack the removed component and send it to the local Huawei warehouse. 4.3.6 Replacing a DMU02C1 Prerequisites  The protective gloves and cabinet door key are available.
  • Page 84: Replacing An Ac Heater

    Step 7 Install the cables based on the recorded information. Step 8 Remove the protective gloves. ----End Follow-up Procedure Pack the removed component and have it sent to the local Huawei warehouse. 4.3.7 Replacing an AC Heater Prerequisites  Tools and the key to the cabinet door are available.
  • Page 85: Replacing A Dc Heater

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Procedure Step 1 Wear the protective gloves. Step 2 Switch off the heater circuit breaker on the ACDU. Step 3 Record the cable connection positions on the heater and disconnect the cables.
  • Page 86: Replacing A Tcuc Control Board

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Figure 4-11 Installing the new heater Step 5 Install the DC heater power cable. Step 6 Remove the protective gloves. ----End 4.3.9 Replacing a TCUC Control Board Prerequisites ...
  • Page 87 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Figure 4-12 Removing the TCUC installation component (H1 equipment cabinet) Figure 4-13 Removing the TCUC Figure 4-14 Removing the TCUC (DEU equipment cabinet) Step 5 Remove the TCUC control board.
  • Page 88 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Figure 4-15 Removing the TCUC control board Step 6 Record the positions of jumper caps on the TCUC control board. Figure 4-16 Jumper caps on the TCUC control board (H1 equipment cabinet) Issue 01 (2020-01-17) Copyright ©...
  • Page 89: Replacing A Heat Exchanger Fan

    Step 11 Disconnect the ground cable of the ESD wrist strap, and remove the ESD wrist strap and ESD gloves. ----End Follow-up Procedure Pack the removed component and send it to the local Huawei warehouse. 4.3.10 Replacing a Heat Exchanger Fan Prerequisites ...
  • Page 90 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Step 2 Record the positions of signal cables on the UIM, and disconnect the cables. Step 3 Unscrew and remove the UIM. Figure 4-18 Removing the UIM05B1 Step 4 Disconnect the interconnection terminal from the fan power cable.
  • Page 91: Replacing An External Circulation Fan (Deu Cabinet)

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Figure 4-20 Installing a fan Step 7 Reconnect the interconnection terminal to the fan power cable. Step 8 Insert the UIM into the correct slot, and tighten the screws.
  • Page 92 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Figure 4-21 Removing an external circulation fan Step 4 Install a new external circulation fan. Install the new external circulation fan in the cabinet using screws. Connect the removed cables to the fan based on the recorded information.
  • Page 93: Replacing An Internal Circulation Fan (Deu Cabinet)

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Figure 4-22 Installing a new external circulation fan Step 5 Connect the power cable. Step 6 Disconnect the ground cable of the ESD wrist strap, and remove the ESD wrist strap and ESD gloves.
  • Page 94 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Step 2 Disconnect the power cable. Step 3 Remove the internal circulation fan. Record the positions where cables are connected to the fan, and disconnect the cables. Remove the internal circulation fan using a screwdriver.
  • Page 95: Replacing A Heat Exchanger Core (Deu Cabinet)

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Figure 4-24 Installing a new internal circulation fan Step 5 Connect the power cable. Step 6 Disconnect the ground cable of the ESD wrist strap, and remove the ESD wrist strap and ESD gloves.
  • Page 96 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Procedure Step 1 Remove the heat exchanger core and record the installation direction of it. Figure 4-25 Removing a heat exchanger core Step 2 Clean the heat exchanger core, or replace it with a new one.
  • Page 97: Replacing A Digital Temperature And Humidity Sensor

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance 4.3.14 Replacing a Digital Temperature and Humidity Sensor Prerequisites  Tools and the key to the cabinet door are available.  The new digital temperature and humidity sensor is intact.
  • Page 98 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance  The new smoke sensor is intact. Procedure Step 1 Connect the ground cable to the ESD wrist strap, and put on the ESD wrist strap and ESD gloves.
  • Page 99: Replacing A Water Sensor

    MTS9514A-GX1401) User Manual 4 Maintenance Follow-up Procedure Pack the removed component and send it to the local Huawei warehouse. 4.3.16 Replacing a Water Sensor Prerequisites  An ESD wrist strap, ESD gloves, ESD box or bag, door key, and required tools are available.
  • Page 100: Replacing A Battery Temperature Sensor

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Figure 4-29 Removing the door status sensor Step 4 Remove the shell of the new door status sensor and remove the screws from the signal cables. Step 5 Properly place a new door sensor at the installation position and tighten the screws.
  • Page 101 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual 4 Maintenance Figure 4-30 Disconnecting the battery temperature sensor cable Step 3 Cut off the cable tie of the battery temperature sensor and remove the sensor. Ensure that the detection probe of the battery temperature sensor is not in contact with a metal surface.
  • Page 102: Technical Specifications

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual A Technical Specifications Technical Specifications The technical specifications described in this section apply only to power cabinets, equipment cabinets, and battery cabinets. For details about the technical specifications of the PSU...
  • Page 103: Electrical Specifications

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual A Technical Specifications A.2 Electrical Specifications Table A-2 Electrical specifications Item Specifications AC input Input system and  220/380 V AC three-phase, four-wire input voltage  220 V AC Single-Phase Input frequency Frequency range: 45–66 Hz;...
  • Page 104: Emc Specifications

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual A Technical Specifications Item Specifications for more than 500 ms, the rectifier locks out. AC surge Nominal surge discharge current: 30 kA (8/20 µs) protection DC surge 10 kA (8/20 µs) in differential mode, 20 kA (8/20 µs) in common...
  • Page 105 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual A Technical Specifications Item Specifications Surge susceptibility  AC power port: differential mode: (Surge) 2 kV; common mode: 4 kV  DC power port: differential mode: 1 kV; common mode: 2 kV ...
  • Page 106: B Electrical Conceptual Diagrams

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual B Electrical Conceptual Diagrams Electrical Conceptual Diagrams Figure B-1 Electrical conceptual diagram Issue 01 (2020-01-17) Copyright © Huawei Technologies Co., Ltd.
  • Page 107: C Associations Between Uim Dry Contacts And Alarms

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual C Associations Between UIM Dry Contacts and Alarms Associations Between UIM Dry Contacts and Alarms Table C-1 Associations between dry contacts and alarms (H2 power cabinet) Port Type Silk Screen...
  • Page 108 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual C Associations Between UIM Dry Contacts and Alarms Port Type Silk Screen Associated Alarm ALM5 LLVD Load fuse blown BLVD Load fuse blown Battery fuse blown ALM6 High battery temperature...
  • Page 109 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual C Associations Between UIM Dry Contacts and Alarms Port Type Silk Screen Associated Alarm alarm; open: normal). default) The setting can be ALM2 Busbar overvoltage modified. Busbar ultra overvoltage Busbar undervoltage...
  • Page 110 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual C Associations Between UIM Dry Contacts and Alarms Port Type Silk Screen Associated Alarm Overvoltage, AC Undervoltage, AC Input Fault When an external direct ventilation battery cabinet or a heat exchanger...
  • Page 111: Acronyms And Abbreviations

    MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual D Acronyms and Abbreviations Acronyms and Abbreviations Alternating current distribution box ACDB Battery low voltage disconnection BLVD DCDB Direct Current Distribution Box Electromagnetic compatibility Electromagnetic interference Electromagnetic susceptibility HTTPS Hypertext Transfer Protocol Secure...
  • Page 112 MTS9000A Telecom Power (Russia, Veon, MTS9304A-HD10A1, MTS9304A-AX10A1, MTS9514A-GX1401) User Manual D Acronyms and Abbreviations MTBF Mean time between failures Power supply unit Residual current device Site monitoring unit SNMP Simple Network Management Protocol Surge protection device Temperature control unit C...

This manual is also suitable for:

Mts9304a-hd10a1Mts9304a-ax10a1Mts9514a-gx1401

Table of Contents