Anti-reverse Protection Unit
IT-E165A User Manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the IT6000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ITech IT6000 Series

  • Page 1 Anti-reverse Protection Unit IT-E165A User Manual...
  • Page 2 Notices Warranty Safety Notices © ITECH Electronic, Co., Ltd. 2025 The materials contained in this No part of this manual may be document are provided “as is”, and reproduced in any form or by any means is subject to change, without prior ( including electronic storage and notice, in future editions.
  • Page 3 Warranty ITECH warrants that the product will be free from defects in material and workmanship under normal use for a period of one (1) year from the date of delivery (except those described in the Limitation of Warranty below).
  • Page 4 This affix product label indicates that you must not discard the electrical/electronic product in domestic household waste. Product Category With reference to the equipment classifications described in the Annex 1 of the WEEE Directive, this instrument is classified as Copyright© Itech Electronics Co., Ltd.
  • Page 5 IT-E165A User Manual a “Monitoring and Control Instrument”. To return this unwanted instrument, contact your nearest ITECH office. Copyright© Itech Electronics Co., Ltd.
  • Page 6 Connection of the instrument to a test object may produce radiations beyond the specified limit. Use high-performance shielded interface cable to ensure conformity with the EMC standards listed above. Safety Standard IEC 61010-1:2010+A1:2016 Copyright© Itech Electronics Co., Ltd.
  • Page 7 Safety Symbols ............................i Regulatory Markings ..........................ii Waste Electrical and Electronic Equipment (WEEE) Directive ..............ii Compliance Information ......................... iv Chapter 1 IT-E165A Introduction ....................... 1 1.1 Introduction ............................2 1.2 How to Use ............................5 Copyright© Itech Electronics Co., Ltd.
  • Page 8 IT-E165A User Manual Chapter 1 IT-E165A Introduction Our company's power supply products, such as the IT6000 series (including IT6000B, IT6000C, IT6000D, IT8000), IT6500C/D series, IT-M3900 series (including IT-M3900B, IT-M3900C, IT-M3900D, IT-M3800), and IT6600 series (including IT6600C, IT6600D), all support the optional IT-E165A module.
  • Page 9 IT8900A/E or IT8900G/L series). 1.1 Introduction The dimensions of IT-E165A-250, IT-E165A-400, and IT-E165A-500 are shown below.  Unit: mm The front panel is shown below. The rear panel is shown below. AC input: 88~264VAC, 50/60Hz, 1.3A max. Copyright© Itech Electronics Co., Ltd.
  • Page 10 When the instrument is running, there is a low level of 0V between OUT and GND, and a high level of 5V in the non-RUN state. The dimensions of IT-E165A-750 and IT-E165A-1000 are as shown in the figure below.  Unit: mm Copyright© Itech Electronics Co., Ltd.
  • Page 11 IT-E165A User Manual The rear panel is shown below. 1. AC input terminals L, N, PE AC input voltage range: 180~550VAC AC input frequency range: 47~63Hz AC input inrush current: 50A (cold start) 2. DC terminals Copyright© Itech Electronics Co., Ltd.
  • Page 12 For battery testing applications, refer to the following steps. Make sure that the power of the battery, IT-E165A, and IT6000 is turned off. Refer to the following diagram to connect the IT6000 series instrument and the DUT (battery). IT-E165A-250, IT-E165A-400, IT-E165A-500 ...
  • Page 13 IT-E165A User Manual IT-E165A-750, IT-E165A-1000  When using both channels of the IT6600 series simultaneously,  connect two IT-E165A units. Connect the power cord of IT-E165A. Start the battery and turn on the IT6000 power switch. Copyright© Itech Electronics Co., Ltd.
  • Page 14 (a passive device) port IN. When the voltage difference between IN and OUT is less • than 3V, the indicator light will show RUN (green light), and the test circuit will be connected. Copyright© Itech Electronics Co., Ltd.
  • Page 15 ERROR (red light), and the test circuit will remain disconnected. 6. After the IT-E165A operates normally (test circuit is connected), set the load operating mode and load value, then turn on the load [On/Off]. Copyright© Itech Electronics Co., Ltd.
  • Page 16 Contact US Thank you for purchasing ITECH products. If you have any doubt about this product, please contact us as follows. 1. Visit ITECH website www.itechate.com . 2. Select the most convenient contact for further consultation.