  • Page 1 IT6000 Series Parallel Assembly Instruction Model: IT6000 Series Version: V1.2/08,2019...
  • Page 2 CAUTION sign until the in- pose. ITECH shall not be held liable Manual Part Number dicated conditions are for errors or for incidental or indirect fully understood and met.
  • Page 3: Table Of Contents

    2.1.1 Safety Precautions ..................2 2.1.2 Pre-assembly Inspection ................4 2.1.3 Preparing Tools and Accessories ..............7 2.2 Starting Assembly ....................8 3 Checking After Assembly ....................15 4 Configuring the Master and Slave..................16 Copyright © Itech Electronic Co., Ltd.
  • Page 4: About This Manual

    Different from the concept mentioned when configuring the master- slave relationship after parallel assembly, please pay attention to the distinction. This series of instrument also has User Manual and Programming Guide. Please get access to related manuals for details. Copyright © Itech Electronic Co., Ltd.
  • Page 5: Parallel Assembly

    • At least 12 inches (30.5 cm) must be left on the front and back of the instrument to ensure sufficient air circulation. Copyright © Itech Electronic Co., Ltd.
  • Page 6 When carrying heavy objects, be prepared to bear the load to avoid sprains or injuries caused by heavy objects. • Be careful when pulling a single unit out, and mind other single units that may be unstably mounted to avoid crushing or crashing injury. Copyright © Itech Electronic Co., Ltd.
  • Page 7: Pre-Assembly Inspection

    Ensure that the temperature and humidity in the assembly Temperature/ site are within the range of temperature and humidity in which humidity the instrument can work properly. For details, refer to the requirements User Manual of corresponding products. Copyright © Itech Electronic Co., Ltd.
  • Page 8 ITECH service team. The accessory list comprises all parts required for installing the instruments. Each part has a unique ITECH material number. You can compare the actual object with the material number in the list. Meanwhile, some major parts are il- lustrated briefly below to help you quickly identify them.
  • Page 9 206098: Protec- tive cover 105214: Fiber Install fiber op- Module tic modules 1. 105133: Fiber Connect fiber optic harness optic cables 2. 105117: Cold- and control pressed termi- cables nal harness Copyright © Itech Electronic Co., Ltd.
  • Page 10: Preparing Tools And Accessories

    Used for tightening the inner hexagon Internal hexago- screws. The screw specifications in- nal wrench clude: M8 × 16, M4 × 10, M6 × 16. The (combined) wrench specifications depend on differ- ent specifications of screws. Copyright © Itech Electronic Co., Ltd.
  • Page 11: Starting Assembly

    (206226). b. Use the internal hexagonal wrench to lock the M5 nut (200824), the spring washer Φ5 (200805), and the flat washer Φ5 (200812) to the cas- ter and bottom plate. As shown below. Copyright © Itech Electronic Co., Ltd.
  • Page 12 M4×10 (200750) to the side bracket and the single unit. The above steps are the stacking steps of two single units. If there are still separate units to be stacked, the same steps can be used. Copyright © Itech Electronic Co., Ltd.
  • Page 13 Install the hole plugs (206507) to the electrode shield (206098). d. Use a cross-point screw driver to lock the cross recessed pan head screws with waisted shanks M4×12(206508) to the electrode shield. 4. Connect the power cords and CTRL cables. Copyright © Itech Electronic Co., Ltd.
  • Page 14 GND/PON, and the second single unit’s GND/ 12V to the third single unit’s GND/PON, and so on, until the last single unit is connected. The wiring diagram is as shown below. Copyright © Itech Electronic Co., Ltd.
  • Page 15 According to the single unit to be connected in parallel, select the position where the fiber module (105214) is inserted. • Select the fiber inner loop for the parallel between the master unit and slave unit. The installation diagram of the fiber module is as follows. Copyright © Itech Electronic Co., Ltd.
  • Page 16 After the above operation is completed, the illustration is as follows. • One master unit and one slave unit Copyright © Itech Electronic Co., Ltd.
  • Page 17 Parallel Assembly • Two master units Copyright © Itech Electronic Co., Ltd.
  • Page 18: Checking After Assembly

    Measurement and checking ment has sufficient heat dissipation space. Do not block the condenser hole with cable harness. The power cords should be free of Check damage, breakage and intermediate connectors, and should be connected firmly. Copyright © Itech Electronic Co., Ltd.
  • Page 19: Configuring The Master And Slave

    After the instrument is powered on, enter the menu to carry out related configurations. And functional verification after configuration. Therefore, please carefully read the following safety precautions. Copyright © Itech Electronic Co., Ltd.
  • Page 20 • During wiring, check that the positive and negative poles of the test cables are properly and tightly connected. Do not connect the posi- tive pole and disconnect the negative pole. Copyright © Itech Electronic Co., Ltd.
  • Page 21 2. Connect the power cables of the single unit to the AC power distribution box. The wiring diagram is as follows. 3. Turn on the switch of the AC power distribution box. 4. Turn on the power switch on the front panel of the single unit. Copyright © Itech Electronic Co., Ltd.
  • Page 22 If the total current value after parallel is displayed, it indicates that the parallel operation is successful; otherwise, it indicates that the parallel operation fails, and the specific reason needs to be checked. • Check the output/input function Copyright © Itech Electronic Co., Ltd.
  • Page 23 8. Check whether the instrument can be loaded normally and whether the voltage and current are displayed correctly. If the instrument is working normally at a small current (2A), proceed to the next step; otherwise, the specific reason should be checked. Copyright © Itech Electronic Co., Ltd.
  • Page 24 If the instrument can work normally even at a high current, it means that the instrument after parallel operation is working properly; other- wise, the specific reason should be checked. Copyright © Itech Electronic Co., Ltd.
  • Page 25 Contact Us Thanks for purchasing ITECH products. In case of any doubts, please con- tact us as follows: 1. Refer to accompanying data disk and relevant manual. 2. Visit ITECH website: www.itechate.com. 3. Select the most convenient contact method, for further information.