Storage
E:32-00 burns alternately
selend or indication
for water supply
burns.
E:34-00 burns alternately
torment.
Cause and Troubleshooting
Water supply hose is kinked.
Lay the water supply hose without kinks.
▶
Tap is closed.
Turn on the tap.
▶
Tap is clogged or calcified.
Turn on the tap.
▶
The amount of water flowing in when the tap is
open must be at least 10 l/min.
The sieves in the water connection of the supply or
AquaStop hose are clogged.
Turn off the appliance.
1.
Unplug the power cord.
2.
Turn off the tap.
3.
Unscrew the water connection.
4.
Remove the sieve from the supply hose
5.
Clean the sieve.
6.
Place the sieve in the supply hose.
7.
Screw the water connection tight.
8.
Check the water connection for leaks.
9.
Plug the power cord back into the wall socket.
10.
Turn on the device.
11.
Water flows continuously into the appliance.
Close the tap.
1.
Contact the service department
2.
→ Page 59
.
Troubleshooting
51
Need help?