Innova DUCTO MULTI THIN Installation Manual
Innova DUCTO MULTI THIN Installation Manual

Innova DUCTO MULTI THIN Installation Manual

Hide thumbs Also See for DUCTO MULTI THIN:

Advertisement

Quick Links

Installation manual
EN
N421105A - Rev. 00 - 05/2024
DUCTO MULTI
THIN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DUCTO MULTI THIN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Innova DUCTO MULTI THIN

  • Page 1 Installation manual N421105A - Rev. 00 - 05/2024 DUCTO MULTI THIN...
  • Page 2 First of all, we would like to thank you for having chosen one of our units. As you will realise, you have made a winning choice by purchasing a product that represents the state of the art in domestic air-conditioning technology. Thanks to the product you have purchased and by following the suggestions in this manual, you will benefit from optimal environmental conditions with the lowest possible energy investment.
  • Page 3: Table Of Contents

    ConTEnTs CONTENTS General information � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � p. 5 1.1 About the manual .
  • Page 4 ConTEnTs 4.3 single connection diagram ......... . . p. 30 4.4 Multiple connection diagram .
  • Page 5: General Information

    GEnERAL InFoRMATIon GENERAL INFORMATION 1�1 About the manual This manual was written to provide all the explanations for • Lists the correct management of the appliance. In the figures  This instruction manual is an integral part of the appli- 1 The numbers indicate the individual components.
  • Page 6: General Warnings

    GEnERAL InFoRMATIon Contains specific warnings and all information necessary It contains specific warnings useful information for the for positioning, mounting, connecting the device and op- most common commissioning and routine maintenance. Technical information eration. Commissioning, maintenance and troubleshooting It addresses all recipients. They are addressed exclusively to the Technical Assistance It contains detailed technical information about the appli- Centre.
  • Page 7: Disposal

    GEnERAL InFoRMATIon 1�4 Disposal The symbol on the product or its packaging indicates that the product must not be treated as normal household waste, but must be taken to the appropriate collection point for the recycling of electrical and electronic equip- ment.
  • Page 8: Product Introduction

    PRoDUCT InTRoDUCTIon PRODUCT INTRODUCTION 2�1 Identification The appliance can be identified by the rating plate: Technical rating plate This shows the technical and performance specifications of 1� Technical rating plate the appliance.  Tampering with, removing or missing identification plates does not allow the product to be reliably iden- tified by its serial number and therefore invalidates the warranty.
  • Page 9: List Of External Components

    PRoDUCT InTRoDUCTIon 2�4 List of external components 1� Electrical panel 2� Hydraulic connection water inlet to the unit including air vent 3� Condensate drain 4� Hydraulic connection water outlet from the unit including air vent 2�5 List of internal components 1�...
  • Page 10: Configurations

    PRoDUCT InTRoDUCTIon 2�6 Configurations 1� Configuration O: hydraulic connections on the left and electrical panel on the right 2� Configuration Y: hydraulic connections on the right and electrical panel on the left...
  • Page 11 PRoDUCT InTRoDUCTIon 2�7 Compatible accessories Description Code Commands for I versions Electronic LED control panel with touch interface, wall-mounted installation complete with thermostat EEB749II and temperature and relative humidity sensor in the environment. Wired connection. White color Electronic LED control panel with touch interface, wall-mounted installation complete with thermostat and temperature and relative humidity sensor in the environment, with integrated Wi-Fi module, EFB749II InnovAPP.
  • Page 12 PRoDUCT InTRoDUCTIon Description Code Grille for telescopic kit for FNC MULTI THIN 60 AHRD0587II Grille for telescopic kit for FNC MULTI THIN 80 AHRD0588II Grille for telescopic kit for FNC MULTI THIN 100 AHRD0589II Grille for telescopic kit for FNC MULTI THIN 120 AHRD0590II Distribution accessories Insulated plenum for horizontal or vertical supply/return with two DN160 inlets and grille connection...
  • Page 13: Installation

    InsTALLATIon INSTALLATION 3�1 Preliminary Warnings  For detailed information on the products, refer to every precaution suggested by common sense and the chapter 9 p. 54. safety regulations in force at the place of installation.  The installation must be carried out by the installer.  Using only the supplied installation-specific compo- There is a risk of water leakage, electric shock or fire if nents is recommended.
  • Page 14: Handling With Packaging

    InsTALLATIon 3�4 Handling with packaging Preliminary Warnings  When the load is lifted from the ground, stay clear of the immediate and surrounding area.  The unit may only be handled by qualified personnel  Check the information on the packaging for the amount adequately equipped and with equipment suitable for of stackable packages.
  • Page 15: Handling Without Packaging

    InsTALLATIon Removing the packaging To remove the packaging: ► use a cutter ► open the cardboard packaging  To aid removal of the product, also cut the vertical edg- ► remove the accompanying components ► remove the polystyrene elements ► remove the appliance from the box Accompanying material They are included with the appliance, inside the packaging: •...
  • Page 16: Minimum Installation Distances

    InsTALLATIon  Avoid installing the unit in the vicinity of the sea. • there are no obstacles to the free circulation of air Salty atmospheres cause corrosion and oxidation through the holes (plants, leaves...) of the internal components, compromising the •...
  • Page 17: Positioning The Unit

    InsTALLATIon Hatch dimensions Models u.m. Hatch dimensions 1410 1610 1810 2100 3�10 Positioning Preliminary Warnings Positioning the unit  Check that: 1� Mounting holes • the surface supports the weight of the appliance • the surface does not affect piping or power lines •...
  • Page 18: Hydraulic Connections

    InsTALLATIon  Check the correct orientation of the unit. ► mark the position of the fixing holes ► use fixing systems appropriate for the type of support- ing surface and the weight of the unit ► secure the unit to the fixing system Check that: •...
  • Page 19: System Connection

    InsTALLATIon Position and dimensions System connection To make the connections: ► position the hydraulic lines ► use the 'key against key' method ► tighten the connections ► check for any leaks ► insulate the connections with insulation material  The hydraulic lines and joints must be thermally insu- lated.
  • Page 20: Attachment Position

    InsTALLATIon Connection with 3-way valve In case of choosing the 3-way valve option: • connect to the lower outlet • electrical connections are required Electrical cable entry Connection for water outlet pipe Connection for water inlet pipe Machine body Thermoelectric motor 3�12 Condensate drain connection Preliminary Warnings 1�...
  • Page 21: Condensate Drain Connection

    InsTALLATIon Connections 100 mm 50 mm 50 mm 1� Condensate drain connection 2� Condensate drain pipe 3� Hose fitting 4� Hose clamp To connect the condensate drain: ► connect the drainage pipe to the connection provided on the unit ► install a siphon on the condensate drainage pipe near the unit ►...
  • Page 22: Correspondence Between The Air Supply Channel And The Electrical Panel

    InsTALLATIon 1� Air relief 3�14 Correspondence between the air supply channel and the electrical panel 1� Configuration O: hydraulic connections on the left and electrical panel on the right 2� Configuration Y: hydraulic connections on the right and electrical panel on the left  The electrical panel 1 and the supply channel 1 are al- parallel, therefore the connection to the power supply ways positioned near the same corner, regardless of...
  • Page 23: Aeraulic Connections

    InsTALLATIon 3�15 Aeraulic connections Preliminary Warnings  To prevent the transmission of any vibrations of the ma- chine into the room, an anti-vibration joint should be  The sizing of ducting and supply and extract grids must placed between the fan outlets and the ducts. be carried out by a professionally qualified person.
  • Page 24 InsTALLATIon Models u.m. Extracted air dimensions 1030 1320 Air supply dimensions Connections number Supply air connection...
  • Page 25: Electrical Connections

    InsTALLATIon 3�16 Electrical connections The appliance leaves the factory fully wired and only re- ards or practices governing the connection of electri- quires connection to the power supply, control and any cal appliances at national level. Insufficient capacity or accessories. incomplete electrical connections could lead to electric shock or fire.
  • Page 26 InsTALLATIon  Before carrying out any work, ensure that the power supply is switched off. 1� Electrical panel closing panel To access the connections: ► remove the fixing screws ► remove the electrical panel closing panel Connections Before connecting the unit to the mains power supply, make sure that the disconnector is open.
  • Page 27: Connection Diagram

    InsTALLATIon Connection diagram 1� 230/1/50 power supply 4� FnC MULTI THIn 2� 5� Disconnector Remote control 3� 6� Power cable Control panel communication cable On-board electrical panel Connection terminal board 230 V - 1F - 50Hz...
  • Page 28: M7 Series Control Code Eeb749

    M7 SErIES COnTrOl COdE EEB749 M7 SERIES CONTROL CODE EEB749 4�1 Interface 1� 2� Display area Keypad area 4�2 Installation Description The wall remote control is an electronic LED thermostat with a touch interface, capable of controlling multiple devic- es equipped with the same electronic board. It is equipped with a temperature and humidity sensor.
  • Page 29 M7 SErIES COnTrOl COdE EEB749  The wall control is supplied already assembled in the 1� 503 electrical box 2� Control base package. 3� Wall control command 1� Control base 2� Wall control command ► close the control panel Before mounting on the wall:  Be careful not to crush the wires when closing the con- trol.
  • Page 30: Single Connection Diagram

    M7 SErIES COnTrOl COdE EEB749 4�3 Single connection diagram DC Inverter fan motor 1-minute delay when the fan coil is in heating mode and is on Earth connection call (clean contact max 1 A) Power supply connection 230 V / 50 Hz / 1 A Presence contact (normally open) -BA+ Water solenoid valve (voltage output at 230V / 50 Hz / 1 A)
  • Page 31: Multiple Connection Diagram

    M7 SErIES COnTrOl COdE EEB749 4�4 Multiple connection diagram 1� Wall control panel M7 series 3� Electronic board 2� 4� Device connection terminal block Board for pairing command and device...
  • Page 32: Connections

    M7 SErIES COnTrOl COdE EEB749 4�5 Connections Preliminary Warnings 1� Terminal block (Panel rear view)  The terminals for connecting the control panel and the CP presence contact are inserted in a plastic bag and placed on the inside of the electrical box cover. 1�...
  • Page 33: Rs485 Serial Connection

    M7 SErIES COnTrOl COdE EEB749 ► when a button is pressed on the display, the sym- ► follow the connection diagram appears ► connect following the A and B indications  It is forbidden to connect the CP input in parallel with For pairing other electronic boards.
  • Page 34: Advanced Menu

    M7 SErIES COnTrOl COdE EEB749 Set humidity hysteresis Adjust volume To set the humidity hysteresis To change the control volume ► select ► select ► Press to change settings ► Press to change settings ► Increase or decrease the value with the icons ►...
  • Page 35: Error Indication

    M7 SErIES COnTrOl COdE EEB749 Pairing between control and device To pair the controller with the device The device has been removed. ► from the powered-on controller, simultaneously To exit the setting press for about 10 seconds ► press for 5 seconds In the display area, where the setpoint is indicated, You exit the setting...
  • Page 36 M7 SErIES COnTrOl COdE EEB749 Displayed alarms 1� ► E2 Internal fan motor fault or disconnect- No device operation can be activated. ► E3 H2/T2 water temperature sensor dis- connected or faulty No device operation can be activated. ► E6 Unsuitable water temperature with automatic season function setting The fan coil performs heating and cooling functions...
  • Page 37: M7 Series Control Code Efb749

    M7 SErIES COnTrOl COdE EFB749 M7 SERIES CONTROL CODE EFB749 5�1 Interface 1� 2� Display area Keypad area 5�2 Installation Description The wall remote control is an electronic LED thermostat with a touch interface, capable of controlling multiple devic- es equipped with the same electronic board. It is equipped with a temperature and humidity sensor.
  • Page 38 M7 SErIES COnTrOl COdE EFB749  The wall control is supplied already assembled in the 1� 503 electrical box 2� Control base package. 3� Wall control command 1� Control base 2� Wall control command ► close the control panel Before mounting on the wall:  Be careful not to crush the wires when closing the con- trol.
  • Page 39: Single Connection Diagram

    M7 SErIES COnTrOl COdE EFB749 5�3 Single connection diagram DC Inverter fan motor 1-minute delay when the fan coil is in heating mode and is on Earth connection call (clean contact max 1 A) Power supply connection 230 V / 50 Hz / 1 A Presence contact (normally open) -BA+ Water solenoid valve (voltage output at 230V / 50 Hz / 1 A)
  • Page 40: Multiple Connection Diagram

    M7 SErIES COnTrOl COdE EFB749 5�4 Multiple connection diagram 1� Wall control panel M7 series 3� Electronic board 2� 4� Device connection terminal block Board for pairing command and device...
  • Page 41: Connections

    M7 SErIES COnTrOl COdE EFB749 5�5 Connections Preliminary Warnings 1� Terminal block (Panel rear view)  The terminals for connecting the control panel and the CP presence contact are inserted in a plastic bag and placed on the inside of the electrical box cover. 1�...
  • Page 42 M7 SErIES COnTrOl COdE EFB749 ► when a button is pressed on the display, the sym- ► follow the connection diagram appears ► connect following the A and B indications  It is forbidden to connect the CP input in parallel with For pairing other electronic boards.
  • Page 43 M7 SErIES COnTrOl COdE EFB749 Set RH sensor offset Adjust volume To change the control volume  Only change after finding actual deviations compared ► select to a real measurement made with professional equip- ► Press to change settings ment. To set the RH sensor adjustment ►...
  • Page 44 M7 SErIES COnTrOl COdE EFB749 UC: not used  By selecting one of the other inputs (Co, CC), the sea- sonality is locked and can no longer be changed using Ac: not used button on the control. Ah: not used Set the radiant options in heating with R20 Ed: not used  To modify the rH function, you need to have the MZs ac-...
  • Page 45 M7 SErIES COnTrOl COdE EFB749 LED indications ► press to access the menu ► Flashing LED ► use the icons to navigate within the menu Errors reported for display. ► select no to keep all the fancoils ► lEd off ►...
  • Page 46: First Start-Up

    sTART-UP START-UP 6�1 Preliminary Warnings  This section is dedicated to the Technical Service  The customer must be present when the appliance is Centre. The specifications of the Technical Service tested and informed of the contents of the manual and Centre are described in chapter p. 5.
  • Page 47: Plant Delivery

    sTART-UP 6�3 Plant delivery once all the checks and controls on the correct operation • the basic functional characteristics of the appliance of the plant have been completed, the installer must ex- • the instructions for use plain the following to the user: •...
  • Page 48: Maintenance

    MAInTEnAnCE MAINTENANCE 7�1 Routine maintenance Annual operations The once-a-year maintenance plan includes the following operations and checks and must be carried out by the Technical Service Centre or by qualified personnel. Electrical circuit Check: • electrical supply voltage • the electrical absorption •...
  • Page 49 MAInTEnAnCE Cleaning or filter replacement 1� lower filter guide 2� Filter 1� Side filter guide 2� Filter...
  • Page 50 MAInTEnAnCE To remove: ► disconnect the power supply to the unit ► remove the screws from the lower filter guide ► remove the lower filter guide ► take out the filter  Pay attention to sharp surfaces  If the condition of the filters is acceptable, they can be cleaned using a vacuum cleaner or a low-pressure compressor.
  • Page 51: Cleaning The Heat Exchanger

    MAInTEnAnCE Cleaning the heat exchanger Cleaning the heat exchanger 1� Lower panel 1� Heat exchanger 2� Condensate collection tray ► disconnect the power supply to the unit ► disconnect the condensate drain pipe ► access the heat exchanger ► gently proceed with the cleaning of the heat exchanger using a vacuum cleaner or a low-pressure compressor To reposition: ►...
  • Page 52: Faults And Remedies

    FAULTs AnD REMEDIEs FAULTS AND REMEDIES 8�1 Preliminary Warnings If one of the following faults is found: ► immediately disconnect the power supply • the ventilation does not activate even if hot or cold water ► close the water valves is present in the hydraulic circuit ►...
  • Page 53: Alarm Table And Card Flashes

    FAULTs AnD REMEDIEs 8�3 Alarm table and card flashes DESCRIPTION OF ALARM CAUSE REMEDY CARD FLASHES Recovery ambient probe / Ex- sensor breakage or failure to Check probe connection or 1 flash - off 3 seconds ternal air alarm - T1 read replace sensor Check the connection of the...
  • Page 54: Technical Information

    TECHnICAL InFoRMATIon TECHNICAL INFORMATION...
  • Page 55: Technical Data

    TECHnICAL InFoRMATIon 9�1 Technical data...
  • Page 56: Dimensions

    TECHnICAL InFoRMATIon 9�2 Dimensions Size 60 Electrical panel Hydraulic connections Condensate drain...
  • Page 57 TECHnICAL InFoRMATIon Size 80 Electrical panel Hydraulic connections Condensate drain 1020...
  • Page 58 TECHnICAL InFoRMATIon Size 100 Electrical panel Hydraulic connections Condensate drain 1031 1220...
  • Page 59 TECHnICAL InFoRMATIon Size 120 Electrical panel Hydraulic connections Condensate drain 1317 1510...
  • Page 60 InnoVA s.r.l. Via I Maggio 8 - 38089 (Tn) - ITALY tel. +39.0465.670104 – fax +39.0465.674965 info@innovaenergie.com...

Table of Contents