FUEL CONNECTION
FUEL RECOMMENDATION
BATTERY VOLTAGE
BATTERY CRANKING AMPS
BATTERY COLD CRANKING AMPS
BATTERY GROUND
LOAD PERCENTAGE
25%
50%
75%
100%
Each generator set is received as a unit except for the optional exhaust system components,
which are shipped loose for assembly after the set is installed in the vehicle. When preplanning the
installation, the following factors must be considered.
1. COMPARTMENT SIZE:
2. AIR REQUIREMENTS:
3. COMPARTMENT FLOOR:
4. COOLING SYSTEM:
5. FUEL SYSTEM:
6. EXHAUST SYSTEM:
7. ELECTRICAL CONNECTIONS:
** NOTE: When using a radiator not supplied by Power Technology consult your radiator
manufacturer to ensure that heat rejection values are met.
SPECIFICATION CHARTS
FUEL CONSUMPTION IN GALLONS PER HOUR
15KW
.33 GPH
.67 GPH
1.01 GPH
1.35 GPH
INSTALLATION FACTORS
Will there be sufficient room around the set to maintain
the minimum clearance of one inch?
Are the compartment air inlets and outlets sized to allow
adequate circulation of air for cooling and combustion?
Is the compartment floor strong enough to support the
weight of the generator set?
Is the cooling system large enough to adequately cool the
generator set? **
Is the fuel system properly designed to prevent fuel
starvation of either the main engine or generator engine?
Will the exhaust system meet all safety requirements
after installation?
Will all systems, (battery, load and remote switch)
DIESEL FUEL No.1-D or No.2-D ASTM / D975
17.5KW
.39 GPH
.79 GPH
1.18 GPH
1.57 GPH
be compatible with the vehicles system?
4
¼" NPT
12 VOLTS DC
420
590 MINIMUM
NEGATIVE
20KW and 25KW
.45 GPH
.90 GPH
1.35 GPH
1.80 GPH