Download Print this page
A&D UT-801 Instruction Manual
A&D UT-801 Instruction Manual

A&D UT-801 Instruction Manual

Multi-function infrared thermometer
Hide thumbs Also See for UT-801:

Advertisement

Quick Links

Multi-function Infrared Thermometer
Model UT-801
1WMPD4003399E
Date of issue: 2024-09-12
Instruction Manual
Original
Manuel d'instructions
Traduction
Original
Manual de Instrucciones
Traducción
Manuale di Istruzioni
Traduzione
使用手冊
‫دليل التعليمات‬
ENGLISH
FRANÇAIS
ESPAÑOL
ITALIANO
中文
翻譯
‫عربي‬
‫ترجمة‬

Advertisement

loading
Need help?

Need help?

Do you have a question about the UT-801 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for A&D UT-801

  • Page 1 Multi-function Infrared Thermometer Instruction Manual ENGLISH Model UT-801 Original Manuel d’instructions FRANÇAIS Traduction Original Manual de Instrucciones ESPAÑOL Traducción Manuale di Istruzioni ITALIANO Traduzione 使用手冊 中文 翻譯 ‫دليل التعليمات‬ ‫عربي‬ 1WMPD4003399E Date of issue: 2024-09-12 ‫ترجمة‬...
  • Page 2: Table Of Contents

    Contents Dear Customers ......................................2 Preliminary Remarks ...................................... 2 Precautions ........................................2 Symbols .......................................... 4 Cautions .......................................... 5 Parts Identification ......................................6 Functions......................................... 7 Installing/changing batteries ..................................9 Measurements......................................10 Troubleshooting ......................................14 Care & Maintenance ....................................15 Technical Data ......................................16 Appendix: EMC Information ..................................
  • Page 3: Dear Customers

    Dear Customers Congratulations on purchasing a state-of-the-art A&D thermometer, one of the most advanced thermometers available today. Designed for ease of use and accuracy, this device will facilitate your health care regimen. We recommend that you read through this manual carefully before using the device for the first time. Preliminary Remarks ▢...
  • Page 4 ▢ Intended use: The ear/forehead thermometer is electronic thermometer using an infrared detector (thermopile detector) to detect body temperature from ear canal/forehead in people of all ages. ▢ Intended operator: The intended operator should have at least eight years of education, including patients or other operators. ▢...
  • Page 5: Symbols

    Symbols The CE mark and Notified Body Follow instructions for use BF type applied part Registration Numbers, the requirement of ANNEX IX excluding Chapter II of MDR (EU) 2017/745 are met. Please do not dispose of the product in the household waste at the end of its useful life. Disposal can take place at appropriate correction points provided in your country.
  • Page 6: Cautions

    Cautions Please read the instructions carefully before using this device, Choking from swallowing small parts and batteries by children or pets is possible, please keep small parts and batteries at places where children and pets can’t reach. The device should not submerge into any liquids and expose it to direct moisture, and please keep away from direct sunlight. If there is certain temperature difference between the places where the device is stored and where you are going to measure, subject and the device should stay in the same room for at least 15 minutes before measurement.
  • Page 7: Parts Identification

    Parts Identification When first time using, please pull out the isolation sheet. Last memory icon Last memory SCAN button Surface icon Stand-by (ON/MEM button) Unique device identifier (UDI) Forehead icon Serial number : Ear icon SN Byymmxxxxx Display B: fix yy: year mm: months xxxx :production...
  • Page 8: Functions

    Functions Ear temperature This thermometer has been designed for everyday use. It’s not meant to replace a visit to the doctor. Please also remember to compare the measurement results to your regular body temperature. Please consult with doctor if you have health concerns. Forehead Temperature This thermometer has been designed for everyday use.
  • Page 9 Memory Locations There are a total of 25 memory sets for the body temperatures. --- When powered on, press the “ON/MEM” button to see the temperatures stored with memory icon. °C / °F Switch In “Power Off” mode, press and hold the “SCAN” button, then press the ON/MEM button for 3 seconds. The temperature icon “°C” will switch to “°F”.
  • Page 10: Installing/Changing Batteries

    Installing/changing batteries 1. Open the battery cover: Insert a coin into the groove of battery cover at the rear of the device and twist it clockwise. The battery is located under the cover. 2. Hold the device and flip the battery out with a small screwdriver. 3.
  • Page 11: Measurements

    Measurement 1. Always make sure the probe is clean and undamaged. 2. Remove the cap. 3. Power on: Press the “ON/MEM” button. 4. Mode selection: ● Ear mode: Press the “ON/MEM” button, the default mode of thermometer is ear mode. The thermometer is can be used after you see the ear icon on the display and hear two beep sounds.
  • Page 12 Forehead temperature measuring: Points for attention: (1) Check the icon on the LCD. (2) Hold the thermometer within 1~2 cm from the central forehead (See picture). (3) Press the "SCAN" button to get the forehead measurement. While scanning, you will hear a beep sound, which indicates you the newest measurement is taking place.
  • Page 13 6. After measurement: (1) Power off: Device will automatically shut off(stand-by) if left idle for more than 1 minute. And the device can only be powered off automatically. (2) Clean the probe after each use to ensure accurate readings and avoid cross contamination. (See the section on "Care & Maintenance" for details.) (3) Device is always displayed the ambient temperature in stand-by and you cannot turn off all displays on LCD.
  • Page 14 - Before the measurement, the subject should stay in a stable environment for 5 minutes and avoid exercise, bath for 30mins. - To avoid the risk of cross contamination, please clean the probe according to “Care & Maintenance” section after each Taking Ear Temperature Taking Forehead Temperature NOTES...
  • Page 15: Troubleshooting

    Troubleshooting Error Problem Recommended Action Take out the battery, wait for 1 minute and Other errors, the system is not functioning properly. reinsert it. If this message reappears, contact the retailer for service. Wait until all the icons stops flashing before Measurement before device stabilization.
  • Page 16: Care & Maintenance

    Care & Maintenance ▢ After measurement, please use a cotton swab with alcohol (70 to 75% concentration) to clean the lens (on the inside of the probe). ▢ Allow the probe to fully dry for at least 1 minutes. Then reattach the cap. ▢...
  • Page 17: Technical Data

    Technical Data Dimensions 125 mm × 37 mm× 22 mm Weight Approx. 41g, excluding the battery. Temperature measurement range Ear/Forehead mode: 34 to 42.2°C(93.2 to 108°F), Surface mode: -22 to +80°C(-7.6 to 176°F), Operating temperature range 10 to 40°C (50 to 104°F) ,15 to 85%RH Storage temperature range Device should be stored at a room temperature between -20 to +50°C and humidity 85% or less.
  • Page 18: Appendix: Emc Information

    Manufacturer s eclaration electroma netic emissions The UT-801 is intended for use in the electromagnetic environment (for home healthcare) specified below. The customer or the user of the UT-801 should assure that it is used in such an environment. Electroma netic en ironment ui ance...
  • Page 19 Manufacturer’s declaration-electromagnetic immunity is intended for use in the electromagnetic environment (for home healthcare) specified below. The customer or the user of the should assure that it is used in such an environment. Electromagnetic IEC 60601 Immunity test Compliance level environment-guidance test level (for home healthcare environment)
  • Page 20 RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the is used exceeds the applicable RF compliance level above, the UT-801 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the UT-801.
  • Page 21 RF communications equipment an t e UT-801 The UT-801 is intended for use in an electromagnetic environment (for home healthcare) in which radiated RF disturbances are controlled. The customer or the user of the UT-801 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the UT-801 as recommended below, according to the maximum output power of the communications equipment.
  • Page 22 Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment The UT-801 is intended for use in the electromagnetic environment (for home healthcare) specified below. The customer or the user of the UT-801 should assure that it is used in such an environment. Maximum...
  • Page 23 GSM 1800; 1 720 CDMA1900; GSM1900; Pulse 1 700 – 1 845 DECT; modulation b) 1 990 LTE Band 217 Hz 1,3,4,25; 1 970 UMTS Bluetooth, Pulse WLAN, 2 400 – 2 450 modulation b) 802.11 b/g/n, 2 570 217 Hz RFID 2450, LTE Band 7 5 240...
  • Page 24 IMPORTER A&D INSTRUMENTS LIMITED (https://andprecision.com) Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxfordshire OX14 1DY United Kingdom Telephone: [44] (1235) 550420 Fax: [44] (1235) 550485 A&D Australasia Pty Ltd. 32 Dew Street, Thebarton, South Australia 5031 AUSTRALIA Telephone: [61] (8) 8301-8100 Fax: [61] (8) 8352-7409 A&D Instruments India Private Limited 509 Udyog Vihar Phase V Gurgaon-122 016, Haryana, India Tel:91(124)471-5555 Fax:91(124)471-5599 Radiant Innovation Inc.