A l l t r a d e m a r k s , b r a n d n a m e s , a n d b r a n d s a p p e a r i n g h e r e i n a r e t h e p r o p e r t y o f t h e i r r e s p e c t i v e o w n e r s .
• C r i t i c a l a n d e x p e d i t e d s e r v i c e s
• I n s t o c k / R e a d y - t o - s h i p
Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate, representative, or authorized distributor for any manufacturer listed herein.
$
650
.00
In Stock
Qty Available: 1
Used and in Excellent Condition
Open Web Page
https://www.artisantg.com/70804-1
• We b u y y o u r e x c e s s , u n d e r u t i l i z e d , a n d i d l e e q u i p me n t
• F u l l - s e r v i c e , i n d e p e n d e n t r e p a i r c e n t e r
Inverters - compact units, cabinet systems, cabinet units air and liquid cooled (218 pages)
Summary of Contents for Siemens SINAMICS G110 CPM110
Page 1
Siemens SINAMICS G110 CPM110 6SL3211-0AB13-5UB1 Inverter In Stock Qty Available: 1 Used and in Excellent Condition Open Web Page https://www.artisantg.com/70804-1 A l l t r a d e m a r k s , b r a n d n a m e s , a n d b r a n d s a p p e a r i n g h e r e i n a r e t h e p r o p e r t y o f t h e i r r e s p e c t i v e o w n e r s .
Page 3
SINAMICS G110 Documentation Getting Started Guide The Getting Started Guide is designed to give the user quick access to all the basic information required to install and set-up the SINAMICS G110 for operation. Operating Instructions Gives information regarding the features of SINAMICS G110 including Installation, Commissioning, Control modes, System Parameter structure, Troubleshooting,...
Page 4
Overview Installation Commissioning SINAMICS G110 Using the 120 W - 3 kW SINAMICS G110 System Parameters Operating Instructions Troubleshooting User Documentation Specifications Options Electro-Magnetic Compatibility Appendices Inverter Type Firmware Version SINAMICS G110 1.0 &1.1 (See Page 4) Index Issue 11/2004...
Page 5
6SL3211-0xxxx-xxx1 4.3.4 Parameter P1234 in DC braking 4.3.5 Compound braking Approved Siemens Quality for Software and Training Other functions not described in this document may be is to DIN ISO 14001, Reg. No. 2160-01 available. However, this fact shall not constitute an obligation to supply such functions with a new control, or when servicing.
Page 6
Customers can access technical and general information at: http://www.siemens.de/sinamics-g110 Contact address Should any questions or problems arise while reading this manual, please contact the Siemens office concerned using the form provided at the back this manual. SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0...
Page 7
Definitions 11/2004 Definitions DANGER For the purpose of this documentation and the product warning labels, “Danger” indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING For the purpose of this documentation and the product warning labels, "Warning" indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
The equipment SHOULD NOT be opened until 5 minutes after the power has been removed. The horsepower (hp) ratings used throughout this document are obtained by comparison to the Siemens 1LA6 and 1LA7 motors and not NEMA/UL rated motors. CAUTION...
Safety Instructions 11/2004 Transport & Storage WARNING Correct transport, storage, erection and mounting, as well as careful operation and maintenance are essential for proper and safe operation of the equipment. CAUTION Protect the inverter against physical shocks and vibration during transport and storage.
60204, 9.2.5.4) Repair WARNINGS Repairs on equipment may only be carried out by Siemens Service, by repair centers authorized by Siemens or by qualified personnel who are thoroughly acquainted with all the warnings and operating procedures contained in this manual.
11/2004 Overview Table of Contents Overview ........................ 15 The SINAMICS G110 ..................... 15 Features........................15 Installation ......................17 General ........................17 Power Losses ......................18 Ambient operating conditions ................. 18 Harmonic Currents....................19 Derating with Pulse Frequencies ................19 Overvoltage and Trip Levels................... 19 Overcurrent Trip Levels ..................
Page 13
Overview 11/2004 Electro-Magnetic Compatibility (EMC)..............73 Electro-Magnetic Compatibility (EMC)..............73 Removal of ‘Y’ Capacitor Link ................79 DIN Rail Mounting Kit ................... 80 Fitting the Basic Operator Panel ................. 82 Description of the BOP ..................83 Applicable Standards ................... 84 List of Abbreviations ....................
Page 14
Motor Overload PTC Connection ..................51 Figure 3-8 Typical Configurations of the Digital Output ................. 52 Figure 4-1 Siemens standard control using ON/OFF1 and REV ............58 Figure 4-2 Siemens standard control using ON/OFF1 and ON_REV/OFF1 .......... 59 Figure 4-3 2-wire control using ON_FWD and ON_REV ...............
Comprehensive protective functions provide excellent inverter and motor protection. The SINAMICS G110 CPM110 with its default factory settings is ideal for a large range of simple V/f motor control applications. Using the comprehensive range of programmable parameters provided with the inverter, the unit can be adapted for a wide range of applications.
Overview 11/2004 Performance Characteristics Fast repeatable response time to control signals Fast Current Limitation (FCL) for trip-free operation Built-in DC injection brake Compound braking Fixed Frequencies Motor potentiometer function Acceleration/deceleration times with programmable smoothing Multi-point V/f characteristic 150% overload for 60 seconds 2-wire/3-wire control Automatic restart after a mains failure Flying start...
11/2004 Installation 2 Installation WARNINGS Work on the device/system by unqualified personnel or failure to comply with warnings can result in severe personal injury or serious damage to material. Only suitably qualified personnel trained in the setup, installation, commissioning and operation of the product should carry out work on the device/system.
Installation 11/2004 The serial numbers consist 13 characters and contains the date of manufacture, e.g. XAP214-123456 XAP214-123456 Characters 1-2 are the site where the product is built XAP214-123456 Character 3 denotes the year e.g. R = 2003 XAP214-123456 Character 4 is the month (1-9 =Jan-Sep, O =Oct, N =Nov, D =Dec) XAP214-123456 Characters 5-6 are the day of the month XAP214-123456 Character 7 is a separator XAP214-123456...
11/2004 Installation Atmospheric Pollution Do not install the inverter in an environment, which contains atmospheric pollutants such as dust, corrosive gases, etc. Water Take care to site the inverter away from potential water hazards, e.g. do not install the inverter beneath pipes that are subject to condensation. Do not install the inverter where excessive humidity and condensation may occur.
Installation 11/2004 2.8 Mechanical Installation WARNING To ensure the safe operation of the equipment, it must be installed and commissioned by qualified personnel in full compliance with the warnings laid down in these operating instructions. Take particular note of the general and regional installation and safety regulations regarding work on dangerous voltage installations (e.g.
11/2004 Installation 2.9 Electrical Installation WARNING To ensure the safe operation of the equipment, it must be installed and commissioned by qualified personnel in full compliance with the warnings laid down in these operating instructions. Never use high voltage insulation test equipment on cables connected to the inverter.
Installation 11/2004 Operation with Residual Current Device If an RCD (also referred to as ELCB or RCCB) is fitted, the SINAMICS G110 inverters will operate without nuisance tripping, provided that: A type B RCD is used. If the SINAMICS G110 inverter is connected to a single-phase grounded-neutral star mains network, an RCD of type A is permissible.
11/2004 Installation Access to the power and motor terminals Figure 2-5 below show the layout of the SINAMICS G110 inverter’s control, power and motor connection terminals. Figure 2-5 SINAMICS G110 Connection Terminals Figure 2-6 SINAMICS G110 DC Terminals Connections SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0...
Page 27
Installation 11/2004 On FSA to access the DC+/DC- terminals the cutout cover must be removed using a small pair of cutters, ensuring that no plastics from the cutout fall into the inverter housing (see Figure 2-6 on page 25). The terminal connection consists of two spades measuring 6.3 mm by 0.8 mm.
11/2004 Installation Figure 2-7 Motor and Power Connections 2.9.3 Avoiding Electro-Magnetic Interference (EMI) The inverters are designed to operate in an industrial environment where a high level of EMI can be expected. Usually, good installation practices will ensure safe and trouble-free operation. If you encounter problems, follow the guidelines stated below.
Installation 11/2004 The inverter can be screened using the methodology shown in Figure 2-8 below. Figure 2-8 Wiring Guidelines to Minimize the Effects of EMI Legend Motor cable Use suitable clips to fix motor and control cable screens securely to metal back plate Mains power cable Retaining screw (inverter fixing bolts) Line commutating Choke...
11/2004 Installation 2.10 SINAMICS G110 Flat Plate Variant The SINAMICS G110 Flat Plate variant has been designed to allow greater flexibility in the installation of the inverter by an advanced user as an individual unit or as part of an automation system.
Installation 11/2004 Free from dents and holes. Made of metal (steel or aluminium). Must not be painted. Must be free from rust. 5. Apply coating of heatsink/thermal contact paste to the inverter’s flat plate. 6. Ensure that the contact paste is spread evenly over the rear surface of the Flat Plate.
11/2004 Commissioning 3 Commissioning This section describes the different methods of how to commission and run the SINAMICS G110 inverter. A prerequisite is that the mechanical and electrical installation has been completed as described in Section 2, starting on page 17 of these Operating Instructions.
11/2004 Commissioning 3.2 Commission Modes Basic commissioning of the SINAMICS G110 Inverter can be performed by using one of the following methods which are suitable for a large range of applications: Using the inverter with its factory default settings by connecting analogue and digital inputs or using the RS485 connections (see Section 3.3.1 on page 35).
The motor rating data; voltage, current and frequency data has already been keyed into the inverter to ensure that the motor is compatible with the inverter. (A Siemens standard motor is recommended). Linear V/f motor speed, controlled by an analogue potentiometer, or via the RS485 connection using the USS variant.
3.3.1 Factory Settings The inverter has already been programmed at the factory for standard V/f applications on a Siemens standard four-pole 3-phase induction motor, that has the same power rating as the inverters. Controlling the speed of the motor is accomplished by connecting the analog inputs...
Commissioning 11/2004 Controlling the speed of the motor is accomplished on the Analog variant by connecting a potentiometer ( 4.7 k ) to the analog input (external switches and potentiometers are not supplied with the inverter) or via the RS485 connections on the USS variant as shown in the Figure 3-3 above.
11/2004 Commissioning Bus termination on USS variant The USS variant of the SINAMICS G110 inverter uses RS485 protocols to communicate with the controlling system and all other inverters connected to the network. It is necessary to terminate the last inverter on the network bus. This is achieved by setting the Bus Termination DIP switches on the front of the inverter to the ‘Bus Termination’...
Commissioning 11/2004 Changing parameters with the Basic Operator Panel The description below serves as an example that shows how to change any parameters using the BOP. These examples can also be used as a guide to configuring the inverter for running via the BOP (start/stop commands and the frequency setpoint are input on the BOP).
Page 40
11/2004 Commissioning NOTE In some cases - when changing parameter values - the display on the BOP shows . This means the inverter is busy with tasks of a higher priority. Changing single digits in parameter values For changing the parameter value rapidly, the single digits of the display can be changed by performing the following actions: 1.
Commissioning 11/2004 Note The speed reading on the BOP is correct if a Siemens standard 4-pole 3-phase induction motor is connected. Otherwise the motor rated speed has to be changed (see Section 3.4.4 on page 46). Warning and fault status...
Page 42
11/2004 Commissioning Table 3-3 Modes of Operation Overview Legend Mode Analog variant USS Variant (Required Optional Equipment) TERMINAL = BOP = PC to Inverter Connection Kit (Requires switches (Analogue input not = STARTER software and potentiometer) supported, command source can however be = supported via external switches) SERIAL...
Page 43
Commissioning 11/2004 The SINAMICS G110 inverters can be operated using the following modes: Terminal This mode provides a simple method of controlling the inverter using switches and a potentiometer and is only available on the Analog variant. The commissioning for this mode is described in Section 3.3.1 on page 35.
11/2004 Commissioning For a complete description of the buttons on the BOP and the procedure for attaching the BOP to the inverter, see Appendices C and D starting on page 82. For more information on using the BOP, please refer to Section 3.3.2 on page 37. If a BOP is fitted and the output frequency is selected to be displayed (P0005 = 21) the corresponding setpoint is displayed approximately every 1.0 seconds while the inverter is stopped.
Commissioning 11/2004 3.4.2 Commissioning Overview Depending on the variant and desired mode (see Table 3-3 on page 41), different possibilities are available for the advanced commissioning. Table 3-4 below gives an overview on how to: Change the motor base frequency Configure the frequency setpoint and command source only Table 3-4 Commissioning Overview...
Page 46
11/2004 Commissioning 3.4.3 Changing the Motor Base Frequency The default motor base frequency of the SINAMICS G110 inverter is 50 Hz. In some parts of the world motors are designed for a base frequency of 60 Hz. Changing the inverter motor base frequency is accomplished using three methods: A DIP switch is provided on the front of the inverter to select the required base frequency (see Section 3.3 on page 34).
Commissioning 11/2004 3.4.4 Quick Commissioning (P0010=1) Quick commissioning is an easy way to optimally configure the SINAMICS G110 inverter to a specific motor. The motor data, taken from the motor rating label, is entered into the inverter and then the inverter calculates the dependent control and protection parameters.
Page 48
11/2004 Commissioning NOTES P0308 & P0309 are only visible if P0003 = 3. For detailed information, please see the Parameter List. P0307 indicates kW or HP depending upon the setting of P0100. For detailed information, please see the Parameter List. Changing motor parameters is not possible unless P0010=1.
Page 49
Commissioning 11/2004 Flow chart Quick Commissioning (Level 1 Only – P0003=1) P0010 Start Quick Commissioning P0700 Selection of Command Source 0 = Ready to Run 1 = Quick Commissioning (Recommended) (on / off / reverse) 30 = Factory Setting 1 = Basic Operator Panel (BOP) Note 2 = Terminal / Digital Inputs Quick Commissioning must be started with P0010=1...
11/2004 Commissioning 3.4.5 Reset to Factory default To reset all parameters to the factory default settings; the following parameters should be set as follows: 1. Set P0010=30. 2. Set P0970=1. NOTE The reset process can take up to 3 minutes to complete. 3.4.6 External Motor Thermal Overload Protection When operated below rated speed, the cooling effect of fans fitted to the motor shaft is reduced.
Commissioning 11/2004 Since the digital input of a PLC has a high impedance, the digital output can also be connected to the PLC using the internal power supply of the inverter using terminal 6 of the inverter, see Figure 3-8 (D) below. An external 24 V power supply is also permissible, see Figure 3-8 (C) below.
Page 52
11/2004 Commissioning 3.4.8 Cloning Parameters with the BOP Warning During the download of parameters from the BOP to the inverter, the digital output may produce a spurious signal. Prior to performing a download from the BOP to the inverter appropriate counter-measures must be taken to ensure that any suspended load is secured, for example, by the use of external brakes or the load being lowered to ground level and secured.
Page 53
Commissioning 11/2004 Once the cloning procedure has started, it cannot be interrupted. It is possible to copy data from inverters of different power and voltage ratings. During download, if the data is not compatible with the inverter, the default values for the parameter will be written to the inverter. During the cloning process any data already held by the BOP is overwritten.
11/2004 Using the SINAMICS G110 4 Using the SINAMICS G110 WARNINGS When operating electrical devices, it is impossible to avoid applying hazardous voltages to certain parts of the equipment. Emergency Stop facilities according to EN 60204 IEC 204 (VDE 0113) must remain operative in all operating modes of the control equipment.
Using the SINAMICS G110 11/2004 4.2 Command Sources (P0700) This parameter determines from which source the inverter receives the Start, Stop and Reverse commands. The SINAMICS G110 has two default settings depending on the inverter variant, see the Quick Commissioning Flowchart on page 48. NOTES The ramp times and ramp-smoothing functions also affect how the motor starts and stops.
The different types of control are enabled using parameter P0727 and selecting one of the following options: Default value: P0727 = 0: Siemens standard control (ON/OFF1, REV) Other settings: P0727 = 1: 2-wire control (ON_FWD, ON_REV) P0727 = 2: 3-wire control (FWDP, REVP, STOP)
The REV command initiated by itself cannot start the motor. ON/OFF1 ON/OFF1 Equivalent Control Inputs Active ON/OFF1 Control Commands Active Active Inverter Frequency Time f out o = OFF1 Figure 4-1 Siemens standard control using ON/OFF1 and REV SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0...
Without any control signal enabled the drive will ramp down to a stop and remain at standstill. ON/OFF1 ON/OFF1 ON_REV/OFF1 ON_REV/OFF1 Equivalent Control Inputs Ignored Act. Active ON/OFF1 Control Commands Active Ignored ON_REV/OFF1 Inverter Frequency Time f out o = OFF1 Figure 4-2 Siemens standard control using ON/OFF1 and ON_REV/OFF1 SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0...
Using the SINAMICS G110 11/2004 4.3.2 2-wire Logic (P0727=1) Overview This method uses two maintained signals, ON_FWD and ON_REV which start/stop the drive and determine the direction of the motor. The advantage of this method of control is that ON_FWD and ON_REV can be switched at any time, independently of the setpoint or frequency output or direction of rotation, and there is no requirement of the motor to ramp-down to 0 Hz before the command is performed.
11/2004 Using the SINAMICS G110 4.3.3 3-wire Control (P0727=2) Overview This method uses three commands to control the operation of the motor: 1. STOP – Causes on OFF1 command to be performed by the inverter. 2. FWDP – Causes the motor to run in a forward direction (run right). 3.
Using the SINAMICS G110 11/2004 4.3.4 3-wire Control (P0727=3) Overview There are three signals associated with this function: 1. OFF1/HOLD – Being maintained closed the opening of the contact will switch the drive OFF and cause a ramp down to 0 Hz. 2.
11/2004 Using the SINAMICS G110 4.4 OFF and Braking Functions 4.4.1 OFF1 This command (produced by canceling the ON command) causes the inverter to come to a standstill at the selected ramp-down rate. Parameter to change ramp-down time see P1121 NOTES ON and the following OFF1 command must have the same source.
Using the SINAMICS G110 11/2004 NOTE If no digital input is set to DC braking and P1233 0, DC braking will be active after every OFF1/OFF3 command with the time set in P1233, when the inverter output frequency (f out) has fallen below the DC braking start frequency set in P1234. 4.4.5 Compound braking Warning For compound braking, DC braking is superimposed with regenerative braking.
11/2004 System Parameters 5 System Parameters 5.1 Introduction to SINAMICS G110 System Parameters The parameters can only be changed by using the optional Basic Operator Panel (BOP) or the Serial Interface. Parameters can be changed and set using the optional BOP to adjust the desired properties of the inverter, such as ramp times, minimum and maximum frequencies etc.
System Parameters 11/2004 5.2 Parameter Overview Figure 5-1 Parameter Overview For a comprehensive description of all the parameters, please consult the SINAMICS G110 Parameter List. SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0...
Troubleshooting 6 Troubleshooting WARNINGS Repairs on equipment may only be carried out by Siemens Service, by repair centers authorized by Siemens or by authorized personnel who are thoroughly acquainted with all the warnings and operating procedures contained in this manual.
Page 67
Troubleshooting 11/2004 Checking for an ON Command If, for example, DIN0 on terminal 3 was set-up to give an ON command, the following procedure would allow the user to check that an ON command is present: 1. Ensure the BOP is connected to the inverter. 2.
11/2004 SINAMICS G110 Specifications 7 SINAMICS G110 Specifications Table 7-1 SINAMICS G110 Performance Ratings Feature Specification Mains operating voltage 200 V to 240 V (±10%) 1AC 120 W to 3.0 kW and power ranges Input frequency 47 to 63 Hz Output frequency 0 Hz to 650 Hz 0.95...
Page 69
16 – 12 16 – 12 16 – 12 The horsepower (hp) ratings are obtained by comparison to the Siemens 1LA6 and 1LA7 motors and not NEMA/UL rated motors. Current data applies for an ambient temperature of 50ºC unless otherwise specified The value applies to the rated mains voltage of 230 V * Indicates the last digit of the Order No.
14 – 10 12 – 8 12 – 8 The horsepower (hp) ratings are obtained by comparison to the Siemens 1LA6 and 1LA7 motors and not NEMA/UL rated motors. Current data applies for an ambient temperature of 50ºC unless otherwise specified The value applies to the rated mains voltage of 230 V * Indicates the last digit of the Order No.
The following accessories are available as options for your SINAMICS G110 Inverter. For more details please refer to the catalogue or contact your local Siemens sales office if you require assistance. Variant Dependent Options Supplementary filter for Class B operation...
Electro-Magnetic Compatibility (EMC) 11/2004 9 Electro-Magnetic Compatibility (EMC) 9.1 Electro-Magnetic Compatibility (EMC) All manufacturers / assemblers of electrical apparatus which “performs a complete intrinsic function and is placed on the market as a single unit intended for the end user” must comply with the EMC directive EC/89/336. There are two routes for the manufacturer/assembler to demonstrate compliance: 9.1.1 Self-Certification This is a manufacturer's declaration that the European standards applicable to the...
EN 61000-3-2 "Limits for harmonic current emissions (equipment input <= 16A per phase)". All Siemens variable speed drives of the SINAMICS G110 range, which are classified as "Professional Equipment" within the terms of the standard, fulfill the requirements of the standard.
Electro-Magnetic Compatibility (EMC) 11/2004 9.1.4 Three general cases of EMC performance are applicable as detailed below Case 1: General Industrial Compliance with the EMC Product Standard for Power Drive Systems EN 61800-3 for use in Second Environment (Industrial) and Restricted Distribution. Table 9-2 Case 1 - General Industrial EMC Phenomenon...
Electro-Magnetic Compatibility (EMC) 11/2004 Case 3: Filtered - for residential, commercial and light industry This level of performance will allow the manufacturer / assembler to self-certify compliance of their apparatus with the EMC directive for the residential, commercial and light industrial environment as regards the EMC performance characteristics of the power drive system.
Electro-Magnetic Compatibility (EMC) 11/2004 Table 9-5 Compliance Table Model Remarks Case 1 – General Industrial 6SL3211-0****-*U*0 Unfiltered units, all voltages and powers. The product standard EN 61800-3 + A11 for “Adjustable speed electrical power drive systems – Part3: EMC product standard including specific test methods” specifies limits for conducted emissions, which cannot be matched from unfiltered inverters in the 2 environment.
11/2004 Removal of ‘Y’ Capacitor Link Removal of ‘Y’ Capacitor Link To use the SINAMICS G110 FSB and FSC on ungrounded supplies the ‘Y’ capacitor (cap) link must be removed as follows: 1. Ensure the inverter has been disconnected from all power supplies. 2.
DIN Rail Mounting Kit 11/2004 DIN Rail Mounting Kit The DIN Rail Mounting Kit is an optional accessory for the SINAMICS G110 inverter. It must be ordered as a separate item using the following Order Numbers: For FSA: 6SL3261-1BA00-0AA0. For FSB: 6SL3261-1BB00-0AA0.
Page 82
11/2004 DIN Rail Mounting Kit 4. Holding the front of the inverter, pull the inverter forward and upwards to release it from the DIN rail. Figure B-1 Installing the DIN Rail Mounting Kit (FSA) SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0...
11/2004 Description of the BOP Description of the BOP Panel/Button Function Effects Indicates The LCD displays the settings currently used by the converter. Status Pressing the button starts the inverter. This button is disabled Start motor by default. To enable this button set P0700 = 1. OFF1 Pressing the button causes the inverter to come to a standstill at the selected ramp down rate.
Underwriters Laboratories UL and CUL LISTED POWER CONVERSION EQUIPMENT for use in a pollution degree 2 environment ISO 9001 Siemens plc operates a quality management system, which complies with the requirements of ISO 9001. NOTICE: Machinery Directive The devices are suitable for installation in machines. According to the machinery directive 89/392/EC the compliance requires a separate certificate of conformity.
11/2004 List of Abbreviations List of Abbreviations Alternating current Analog digital converter ADC1 Analog input 1 Basic operator panel Cold Plate Assembly Controlled Power Module Constant torque Direct current Digital input Dual in-line package (switch) DOUT Digital output European Community ELCB Earth leakage circuit breaker Electro-magnetic compatibility...
Page 87
List of Abbreviations 11/2004 SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0...
11/2004 Index Index Drill pattern for SINAMICS G110 · 21 2-wire control · 55 2-wire Logic · 58 Electrical Installation · 23 Electro-Magnetic Compatibility 3-wire control · 55 general · 73 3-wire Control · 59, 60 self-certification · 73 technical construction file · 73 Abbreviations ·...
Page 89
Index 11/2004 Serial · 42 Operation Shock · 18 starting and stopping the motor · 54, 61 Siemens standard Control · 56 Operation with SINAMICS G110 long cables · 24 available options · 71 Residual Current Device · 24 general · 15 ungrounded IT supplies ·...
Suggestions and/or Corrections Suggestions Siemens AG Corrections Automation & Drives Group For Publication/Manual: SD SM 5 P.O. Box 3269 SINAMICS G110 Operating Instructions D-91050 Erlangen Federal Republic of Germany Email: documentation.sd@siemens.com User Documentation From Operating Instructions Name: Order Number: Company/Service Department...
Need help?
Do you have a question about the SINAMICS G110 CPM110 and is the answer not in the manual?
Questions and answers