Page 1
Jøtul F 200/F 205 UKCA UKCA - Information UK - Installation and operating instructions F 200 - Classic F 205 - Modern Manualen må oppbevares under hele produktets levetid. Käyttöohje on säilytettävä tuotteen koko käyttöiän ajan. The manuals which are enclosed with the product must be kept throughout the product’s entire service life. Les manuels fournis avec le produit doivent être conservés pendant toute la durée de vie du produit.
Page 2
Attention! Use this approval label when the stoves has been installed (only for UK). Cut off the bottom part and replace the label already attached with this one. It is important that the lot + pin number is viewable. Note: An approved CO monitor should be installed in the same room as the appliance.
ENGLISH UK - Installation and 1.0 Relationship to the operating instructions authorities Installation of a fi replace must be according to local codes and regulations in each country. Table of contents All local regulations, including those which refer to national and European standards, must be observed when installing 1.0 Relationship to the authorities the product.
ENGLISH 3.0 Safety Requirements for protection of infl ammable fl oors under the fi replace NB! To guarantee optimal performance and safety, Jøtul The fl oorplate must comply with national laws and regulations. recommends that its stoves are fi tted by a qualifi ed Contact your local building authorities regarding restrictions installer (see www.jotul.com for a complete list of dealers).
ENGLISH 4.0 Installation Fig. 3b Installation of the door handle (F 205 - modern) • Before installing the fi replace, check it carefully for any signs of damage. • The product is heavy! Ask someone to help you when positioning and installing it. •...
Page 10
ENGLISH 4.3 Assembly with an external air Fig. 4b supply (optional extra - 51047509) Fresh air supply The air used for combustion in any well-insulated house needs to be replaced. This is particularly important in houses with mechanical ventilation. Such replacement air can be procured in several ways.
Page 11
ENGLISH Fig. 6b Through the fl oor and ground plate Fig. 8a Switch between rear outlet and bottom outlet for outdoor air 1. Loosen the two screws that secure the outdoor air adapter. Fig. 8b Fig. 6c Through the fl oor and basement 2.
ENGLISH Fig. 9 Installation of cover for outdoor air minimum dimensions. (Optional equipment - 50061978) • Use a fl ue pipe bend with a sweep hatch to allow sweeping. • Flue pipe bends with any change in direction infl uence/ reduce the chimney draught.
ENGLISH 4.7 Requirement for UK - 5.0 Daily use Smoke control Areas 5.1 Odours when using the fi replace for the fi rst time The Clean Air Act Odours when using the fi replace for the fi rst time “The Clean Air Act 1993 and Smoke Control Areas” When the fi...
Page 14
ENGLISH Fig. 13 Be especially careful never to use the following materials as fuel in your fi replace: • Household rubbish, plastic bags, etc. • Painted or impregnated timber (which is extremely toxic). • Laminated wooden planks. • Driftwood These may harm the product and are also pollutants. NB: Never use petrol, paraffi...
ENGLISH 5.8 Removing the ashes 5.11 The importance of the chimney • Only remove ashes when the fi replace is cold. The chimney is the engine that drives the fi replace and it’s • Use a showel to scrape the ashes out, but always leave essential to have a good chimney in order for the fi...
ENGLISH 7.0 Service 6.3 Sweeping of fl ue pipes to the chimney Any unauthorised modifi cations to the product are prohibited! Only original spare parts may be used! On certain free-standing fi replaces the top plate can be lifted off and the pipe swept through the top. Otherwise, fl...
Page 17
ENGLISH 7.2 Replacing the exhaust defl ectors 7.3 Replacing the burn plates and ash grate Fig. 17 Fig. 20 Replacing the ash grate 1. Lift the upper defl ector up to the rear edge. This is located on a groove in the lower defl ector, see fi g. 18. 2.
ENGLISH Fig. 22a Replace the rear burnplate Fig. 23 Insulation mat on rear burner plate OBS! Ash grate and side burner plates must be removed fi rst 1. the insulation mat (A) is inserted into the groove on the back of the burner plate (B), before carefully refi tting the burner plate as shown in fi...
ENGLISH 9.0 Optional equipment 2. The guarantee does not cover: 2.1. Damage to consumables such as burn plates, fi re grates, fl ue baffl es, gaskets and similar as these deteriorate over 9.1 External air supply cover time due to normal wear and tear. 2.2.
Page 20
Jøtul arbeider kontinuerlig for om mulig å forbedre sine produkter, og vi forbeholder oss retten til å endre spesifi kasjoner, farger og utstyr uten nærmere kunngjøring. Jøtul works continuously to improve its products if possible, and we reserve the right to change specifi...