PCI Hot Plug support

PCI Hot Plug is the ability to physically insert, remove, or replace PCI adapters while a ProLiant server
is powered on. PCI Hot Plug operations may be performed under Windows Server 2003
supported ProLiant servers with the PCI Hot Plug Filter Driver installed. ProLiant storage options and
network interface controllers are supported for PCI Hot Plug operations.
Table 9 identifies ProLiant servers that are capable of PCI Hot Plug.
Table 9. ProLiant servers with PCI Hot Plug support
HP ProLiant DL servers
ProLiant DL380 G2
ProLiant DL380 G3
ProLiant DL580
ProLiant DL580 G2
ProLiant DL740
ProLiant DL760
ProLiant DL760 G2
NOTE:
Future service pack papers will not include PCI Hot Plug support
information, as it applies to older ProLiant server models.

Hot Plug Memory support

Higher availability on HP and Microsoft solutions has been achieved through the deployment of Hot
Plug RAID Memory, the most robust memory-protection solution in the HP Advanced Memory
Protection scheme. With the introduction of industry-leading ProLiant 8-way platforms, the ProLiant
DL760 G2 and ProLiant DL740, HP became the first and only vendor to offer Hot Plug RAID Memory
in an industry-standard platform. These two platforms based on the HP F8 chipset enable customers to
deploy mainframe levels of availability in their industry-standard IT environments, without the high cost
of mainframe technology. With these HP/Microsoft solutions, customers can dynamically hot-add
memory capacity without powering down the server. These solutions deliver true resource scalability
and maximum uptime for enterprise customers. The Hot Add Memory feature in the specified 4-way
and 8-way ProLiant servers is only supported in Windows Server 2003.
The following Hot Plug RAID Memory Driver and Utility are included in Version 7.60A and earlier of
the ProLiant Support Pack for Microsoft Windows Server 2003:
• HP ProLiant Hot-Plug Memory Configuration Utility for Windows Server 2003
• HP ProLiant Hot Plug Memory Driver for Windows Server 2003
NOTE:
Future service pack papers will not include Hot Plug Memory
support information, as it applies to older ProLiant server models.
HP ProLiant ML servers
ProLiant ML370 G2
ProLiant ML530 G2
ProLiant ML570
ProLiant ML570 G2
ProLiant ML750
on
SP2
Compaq ProLiant servers
ProLiant 6400R
ProLiant 6500 Xeon
ProLiant 7000 Xeon
ProLiant 8000
ProLiant 8500
21

Advertisement

Table of Contents
loading

Table of Contents