RC GROUP MP2000 User Manual page 99

Air conditioners microprocessor control
Table of Contents

Advertisement

Software per condizionatori d'aria a pompa di calore e Roof Top • EPROM CPX.... • Software for heat pump air conditioners and Roof Top
ON DISPLAY
Clock board
Supervisor code
Supervisor mode
Probe selction
Supply air temp.
Outl. water temp.
Ext. air temp.
Room humidity
Integr. humidif.
High pressure probe present
Min. scale
Max. scale
Low pressure probe min. scale
Low pressure probe max. scale
Analog input 7 board 1 used like
Analog input 7 board 2 used like
Analog input 8 board 2 used like
Voltage line max scale
Line current max scale
Configuration
Enable heater
Condenser type
Unloader comp.
En. double speed
Analog out.1 board 1
Analog out.1 board 2
RC GROUP - 149_ItEn.0102
MP2000 AIR CONDITIONERS
CONFIGURAZIONE UNITA'
Premere per 4 secondi
quindi inserire Password
TIPO DI SET
scheda orologio
codice supervisione
modo supervisore
selezione sonda
temperatura mandata aria
uscita acqua condensatore
temperatura aria esterna
umidità ambiente
umidificatore integrato (*)
presenza sonda di alta pressione
scala minima pressione
scala massima pressione
scala minima sonda di bassa pressione
scala massima sonda di bassa pressione low pressure probe max. scale
ingr. analogico 7 board 1 usato come (*)
(*) con "Integr. humidif. Y" è utilizzato in
automatico per corrente umidificatore e
questo set non viene visualizzato.
ingr. analogico 7 board 2 usato come
ingr.analogico 8 board 2 usato come
scala massima tensione linea
scala massima corrente linea
configurazione unità
abilitazione riscaldamento
tipo di condensatore
parzializzazione compressore
compressore doppia velocità
uscita analogica xY0 board 1
uscita analogica xY0 board 2
UNIT CONFIGURATION
Press for 4 seconds
PRG
HOME
than digit Password
1
3
SET TYPE
clock board
supervisor code
supervisor mode
probe selection
supply air temperature
outlet condenser water
external air temperature
room humidity
integrated humidifier (*)
high pressure probe present
min pressure scale
max pressure scale
low pressure probe min. scale
analog input 7 boad 1 used like (*) not used
(*) with "Integr. humidif. Y" it is automatically
used for humidifier current measurement
and this set is not displayed
analog input 7 boad 2 used like
analog input 8 board 2 used like
max voltage line scale
max line current scale
unit configuration
2 compr. - 2 circ. - 2 board —
2 compr. - 1 circ. - 2 board —
2 compr. - 1 circ. - 1 board —
enable heater
condenser type
unloader compressor
double speed compressor
analog output xY0 board 1
analog output xY0 board 2
DEFAULT
RANGE
N
N - Y
0
00
99
R
R - W
N
N - Y
N
N - Y
N
N - Y
N
N - Y
N
N - Y
N
N - Y
0 kPa
500 kPa
3000 kPa
0 5000 kPa
0 kPa
0 500 kPa
1500 kPa
0 1500 kPa
not used
voltage line
line current
ext. compens.
not used
not used
voltage line
line current
ext. compens.
not used
not used
voltage line
line current
ext. compens.
600 V
0 700 V
100 A
0 700 A
1 compr. - 2 board
1 compr. - 1 board
N
Y - N
AIR
AIR - WATER
N
N - Y
N
N - Y
cooling valve
cooling valve
heating valve
not used
cool valve +dehumid
cooling valve
cooling valve
heating valve
not used
cool valve +dehumid
SYMBOL
xY0
xY0
99