RC GROUP MP2000 User Manual page 67

Air conditioners microprocessor control
Table of Contents

Advertisement

Software per condizionatori d'aria • EPROM CZX.... • Software for air conditioners
ON DISPLAY
Clock board
Supervisor code
Supervisor mode
Probe selction
Supply air temp.
Outl. water temp.
Ext. air temp.
Inlet water temp.
Room humidity
Integr. humidif.
Pressure probe present
Min. scale
Max. scale
Analog input 7 used like
Analog input 8 used like
Voltage line max scale
Line current max scale
Configuration
Unit no. present
Heater no.
Unloader comp.
En. double speed
Analog input 7 board 2 used as
Line current
Max. scale
Analog input 8 board 2 used as
Voltage line
Max. scale
Analog output 1
Cooling fl. valve
Heating fl. valve
RC GROUP - 149_ItEn.0102
MP2000 AIR CONDITIONERS
CONFIGURAZIONE UNITA'
Premere per 4 secondi
quindi inserire Password
TIPO DI SET
scheda orologio
codice supervisione
modo supervisore
selezione sonda
temperatura mandata aria
uscita acqua refrigerata
temperatura aria esterna
ingresso acqua refrigerata
umidità ambiente
umidificatore integrato (*)
presenza sonda di pressione
scala minima pressione
scala massima pressione
ingresso analogico 7 usato come (*)
(*) con "Integr. humidif. Y" è utilizzato in
automatico per corrente umidificatore e
questo set non viene visualizzato.
ingresso analogico 8 usato come
scala massima tensione linea
scala massima corrente linea
configurazione unità
numero unità presenti in rete
numero stati riscaldamento elettrico
parzializzazione compressore
compressore doppia velocità
ingresso analogico 7 board 2 usato come analog input 7 board 2 used as
corrente di linea
scala massima corrente
ingresso analogico 8 board 2 usato come analog input 8 board 2 used as
voltaggio di linea
scala massima tensione
uscita analogica xY0
valvola 3 punti raffreddamento ad acqua
valvola 3 punti riscaldamento ad acqua
UNIT CONFIGURATION
Press for 4 seconds
PRG
HOME
than digit Password
1
3
SET TYPE
clock board
supervisor code
supervisor mode
probe selection
supply air temperature
outlet water temperature
external air temperature
inlet water temperature
room humidity
integrated humidifier (*)
pressure probe present
min pressure scale
max pressure scale
analog input 7 used like (*)
(*) with "Integr. humidif. Y" it is automatically
used for humidifier current measurement
and this set is not displayed
analog input 8 used like
max voltage line scale
max line current scale
unit configuration
2 compr. - 2 circ. - 2 board —
2 compr. - 1 circ. - 2 board —
2 compr. - 1 circ. - 1 board —
units no. present in network
heaters step number
unloader compressor
double speed compressor
line current
max current scale
voltage line
max voltage scale
analog output xY0
cooling floating valve (water)
heating floating valve (water)
DEFAULT
RANGE
N
N - Y
0
00
99
R
R - R/W
N
N - Y
N
N - Y
N
N - Y
N
N - Y
N
N - Y
N
N - Y
N
N - Y
0 kPa
500 kPa
3000 kPa
0 5000 kPa
not used
not used
voltage line
line current
ext. compens.
not used
not used
voltage line
line current
ext. compens.
conductivity
600 V
0 700 V
100 A
0 700 A
1 compr. - 2 board
1 compr. - 1 board
0 compr. - 2 board
0 compr. - 1 board
1
1 - 2 - 3 - 4
0
0 - 1 - 2 - binary
N
N - Y
N
N - Y
N
N - Y
100 A
0 500 A
N
N - Y
600 V
0 700 V
cooling valve
cooling valve
heating used
not used
cooling + freecooling
cool valve +dehumid
N
N - Y
N
N - Y
SYMBOL
xY0
67