Page 1
AC unit. Installation is easy. The user simply “teaches” th e Beta-1 how to control the AC by using the remote control that comes with their AC unit. Once the Beta-1 learns the lR remote signals, the Beta-1 will automatically change the settings on their AC unit, to temperature settings selected by the user.
Page 2
IR Receiver LCD Sreen Day Status Night Status Photocell Sensor Power Supply Cord Down Setting Enter Back IR Emitter Sensor Holder IR Emitter...
SAFETY The Beta-1 has other important built-in safety functions. Power reset: lf power is interrupted to the Beta-1, it will resend the lR signal to turn on your AC back on to the correct temperature. Temperature monitoring: To ensure the AC has been set to the desired user temperature, the BETA-1 will also constantly monitor the environment temperature using its temperature sensor.
Page 4
OPERATION INSTRUCTIONS Teaching (learning) theremote control codes The next step is to teach the Beta-1 your remote control “codes". Before you start, you must first figure out the setting range for YOUR particular AC unit. Using the remote control that came with your AC, use the UP and DOWN buttons to display, and then write down the lowest and the highest possible temperature settings that your remote control allows.
Page 5
AC, the value that you wrote down earlier. The default LOWEST temperature set-point for the Beta-1 will be 50°F / 10°C. So next use the up button on the Beta-1 to adjust the temperature setting to your desired lowest set-point to be the same as the lowest possible setting on the remote control.
Page 6
°F ENTER button *If the BETA-1 failed to learn the Remote code during the process, the LCD will show “Error" and stay at the unlearned set-point. Adjust the remote set-point backwardly to send the same set-point signal tp redo the learning process.
Page 7
1. Set Day Temperature Set-point Press the Setting button to enter the Day set-point page. Use the up and down buttons to adjust the set-point and then press the Enter button. → 2. Set Night Temperature Set-point Press the Setting button to enter the Night set-point page. Use the up and down buttons to adjust the set-point and then press the Enter button.
COOL mode. With this example above, you will be able to set the BETA-1 to send heating or auto settings to the mini-split from 64 to 72 degrees, and send cooling signals to the mini-split from 73 to 86 degrees.
Need help?
Do you have a question about the BETA-1 and is the answer not in the manual?
Questions and answers