BETA Series -Single Controller OVERVIEW Thank you for purchasing the TrolMaster's BETA-6 Day/Night Humidity Controller. BETA-6 offers indoor gardeners an economical and simple method of monitoring and controlling humidity level within the grow area. It utilizes a highly visible and intuitive LED screen to let you know current humidity level or max/min humidity recorded values.
Page 2
Humidifying Device LED Indicator Dehumidifying Device LED Indicator LED Screen Day/Night Humidity Setpoint LED Indicator Max/Min Humidity Record LED Indicator Humidity Device LED Indicator Power Supply Cord Down Home Power Output for Humidity Humidity Device Sensor...
FEATURES LED Display, Easy Operation ● Built-In Photocell Detecting Day/Night Status ● Alternative Humidifyingor Dehumidifying Function ● Humidity Sensor with 16ft Cable for Close Placement to Plant Canopy ● INSTALLATION Mount the Controller on the wall, place the sensor at plant height in a well- ventilated area. ●...
Page 4
2. Set Humidifying or Dehumidifying Mode Press the HOME button for 1 time, the Humidifying LED indicator or the Dehumidifying LED will be flashing and no digital display on the LED screen. Press UP or DOWN button to indicator convert between Humidifying and Dehumidifying mode. The unit will automatically save the change. When the connected device is for humidifying purpose (such ashumidifier), please select the Humidifying mode.
Page 5
3. Set DaySetpoint Press the Home button for 2 times, the Day Setpoint LED indicator will be flashing and the LED screen will display current humidity Day Setpoint. Press UP or DOWN button to change the setpoint. The unit will automatically save the change. When the humidifying mode is selected (humidifier connected) and the humidity is detected BELOW the setpoint, the BETA-6 Controller will automatically turn on the power supply of the humidifier and its LED indicator stays on.
Page 6
4. Set Night Setpoint Press the Home button for 3 times, the Night Setpoint LED indicator will be flashing and the LED screen will display current humidity Night Setpoint. Press UP or DOWN button to change the setpoint. The unit will automatically save the change.
Page 7
5. Max/Min Recorded Value After power-on, the LED screen will display the current humidity. Press UP or DOWN button, the LED screen will display the Max or Min recorded value respectively. lt will keep flashing for 1 minute and then turn back to normal measured humidityvalue. While the value is flashing, long press HOME button and the Max or Min recorded value will be deleted.