Page 2
KONA • Read the warnings in this instruction Contact professionally qualified per- booklet carefully, since they provide sonnel. Any repair/replacement of important information on installation, parts must only be carried out by pro- use and maintenance. fessionally qualified personnel using •...
Page 3
KONA • In case of doubt, do not use the unit. • UNIT INTENDED FOR DOMESTIC Contact the supplier. USE, NOT SUITABLE FOR INDUS- • The unit and its accessories must be TRIAL USE appropriately disposed of in compli- ance with current regulations.
Page 5
KONA The new is a high performance, low emissions FULLY SEALED water heater for the production of domestic hot water, running on and equipped with high modulation, state of the art burner which reduces the emission of pollutant gases and provides stable and precise combustion.
Page 6
KONA From STANDBY mode, by touching the Standby button the unit If this mode is disabled, it is necessary to touch the button. enters OPERATION mode, the display turns on. From OPER- The symbol will light up on the display immediately.
Page 7
KONA • The combustion circuit is sealed with respect to the place of Before installing the water heater, make installation and therefore the unit can be installed in any room. sure the water and gas connections are The place of installation must be sufficiently ventilated to pre- vent the creation of dangerous conditions in case of gas leaks.
Page 8
KONA WATER inlet symbol GAS inlet symbol HOT WATER outlet symbol °fH °fH The gas connection (see Section 4.1) must be carried out in Fig. 1 - compliance with current regulations. Carry out the connection with a rigid metal pipe (for the gas...
Page 9
KONA • Make sure the hose complies with current regulations. • Avoid areas with heat emission. • Avoid bending or pinching the hose. • The connections on both sides (gas valve and other components) must comply with the national regulations.
Page 10
KONA • Coaxial intake / exhaust duct kit • For connection of separate pipes Ø 80/100 (010039X0): For connection 90° + coaxial pipe, Ø 60/100 (010040X0): Before installation, check by a simple calculation that the maximum permissible flue length is not exceeded: 1.
Use the following procedure to install the conversion Kit: ing and on the technical data plates. • Disconnect the KONA water heater from the power supply. The unit can run on NATURAL GAS (G20, G25), PROPANE AIR • Remove the burner manifold and fit the new one according to (G230) or LPG (G30, G31).
). To convert from G30 to G31, still Total maximum pressure (entire burner) 20 - F0 for the KONA LPG model, the procedure would be the same up to this point, modifying the parameter FA with the corresponding value. Minimum pressure (burner minimum section) 20 - F0 B.
Page 13
KONA To set the parameter , touch the “ ” or “ ” button on the panel until the pressure gauge indicates the Minimum • Check the tightness of the gas system with soapy water to detect nominal pressure plus 0.5 mbar. Wait 10 seconds for the any leaks in the connections.
Page 14
KONA Undo the screws Remove the front panel Disconnect the display panel cable relevant code. At the same time, an acoustic signal sounds. If a fault occurs, all the gas valves are turned off immediately. The fan keeps running for 30 seconds until stopping.
Page 15
“ ” Par. Description Range Default value KONA 12 KONA 15 KONA 17 Unit adjustment: - Type of water heater (12 L, 15 L, 17 L) 1 - 15 G20 G31 G30 G25...
KONA OPTIONAL ACCESSORY Gas inlet [10] Smoke chamber Cold water inlet [11] Fan Domestic hot water outlet (DHW) outlet [12] Temperature limiter Gas valve [13] Electronic board (PCB) Flowmeter [14] Gas manifold Cold water temperature sensor [15] Hot water temperature sensor...
Page 18
KONA (IT) 2HM3B/P (FR) 2Esi3P (IE) 2H3B/P (FR) 2Er3P (FR) 2R3R (PL) 2ELwLs3B/P (GB) 2H3P 29.7 20.9 10 x 0.74 16 x 0.75 16 x 0.75 No. x Ø 10 x 1.07 16 x 1.13 16 x 1.13 mbar mbar 12.5...
Page 19
KONA 0DK96IAA 0DK95IAA 0DK97IAA CODE 0DK96KAA 0DK95KAA 0DK97KAA 0.082 0.082 0.082 21.052 20.996 20.996 Water flow sensor Water inlet NTC probe Water outlet NTC probe Temperature control sensor Ground wire PROPORTIONAL gas valve Gas ON/OFF valve Coil 1 line Coil 2 line (15/17 L)