Page 1
Intel® Storage Adapters RS3P4GF016J and RS3P4QF160J Hardware User Guide A document providing an overview of product features, specification data, and hardware installation instructions. Rev. 1.3 March 2022 Delivering Breakthrough Data Center System Innovation – Experience What’s Inside!
Page 2
Intel® Storage Adapters RS3P4GF016J and RS3P4QF160J Hardware User Guide <Blank page>...
• Added missing heartbeat LED on figure 3. • Corrected cable names on figures 10 and 11. • Added support for the Intel Server Systems R2000WF and R1000WF Families. • Corrected cable names on figures 11 and 12. • Removed safety page.
Page 4
Current characterized errata are available on request. You may not use or facilitate the use of this document in connection with any infringement or other legal analysis concerning Intel products described herein. You agree to grant Intel a non-exclusive, royalty-free license to any patent claim thereafter drafted which includes subject matter disclosed herein.
Page 5
Intel® Storage Adapters RS3P4GF016J and RS3P4QF160J Hardware User Guide Warnings Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals.
Figure 5. Intel® Storage Adapter RS3P4QF160J SFF-8654 Connector ................21 Figure 6. Intel® Storage Adapter RS3P4QF160J Card Connection to the 2U Intel® Server System M50CYP Backplane for SAS / SATA Drives ............... 23 Figure 7. Intel® Storage Adapter RS3P4QF160J Card Connection to the 2U Intel®...
Characteristics. Details on the characteristics for each of the products covered by this guide. • Hardware Installation. Support for the installation of the product on the Intel systems (where they are supported). • Safety and Regulatory (Class A). Covers intended application, also the product’s compliance on safety, EMC, and environmental aspects.
Intel® Storage Adapters RS3P4GF016J and RS3P4QF160J Hardware User Guide Product Overview The Intel Storage Adapters RS3P4QF160J and RS3P4GF016J are part of the second generation of tri-mode Intel storage adapters. This new generation of host bus adapters (HBAs) provides the capability of installing...
The Intel Storage Adapter RS3P4QF160J includes a Serial Attached SCSI (SAS) interface and a Non-Volatile Memory Express (NVMe) interface. By using the proper cables, it is possible to connect NVMe only drives, SAS / SATA drives, or a mix of them. The Intel Storage Adapter RS3P4GF016J includes only an external SAS interface.
Common clock and SRIS drive support. Safety Characteristics All the tri-mode Intel storage adapters meet or exceed the requirements of UL flammability rating 94 V0. Each bare board is also marked with the supplier name or trademark, type, and UL flammability rating.
The tri-mode Intel storage adapters include a UART interface for special debugging purposes. The UART connector debug port requires a special cable and Intel support to gather detailed ROC / IOC status. The UART connector uses the layout shown in the following table.
Intel® Storage Adapter RS3P4QF160J Description The Intel Storage Adapter RS3P4QF160J with 16 internal ports is based on the Avago* SAS3816 IOC. It has an x8 PCI Express (PCIe) 4.0 interface and it supports up to: 1024 physical SAS / SATA devices; 4 direct attach NVMe drives;...
Intel® Storage Adapters RS3P4GF016J and RS3P4QF160J Hardware User Guide 4.1.2 Intel® Storage Adapter RS3P4QF160J Dimensions The next figure shows the dimensions for the Intel Storage Adapter RS3P4QF160J in millimeters, without the PCI bracket. Figure 2. Intel® Storage Adapter RS3P4QF160J Dimensions...
Relative humidity range is 20–80% non-condensing. • Temperature range: 0–+55 °C (with or without the RMFBU Adapter attached). List of non-operating conditions (while in storage or in transit) for the Intel Storage Adapter RS3P4QF160J: • Relative humidity range is 5–95% non-condensing.
Intel® Storage Adapter RS3P4GF016J Description The Intel Storage Adapter RS3P4GF016J with 16 internal ports is based on the Avago SAS3816 IOC. It has an x8 PCIe 4.0 interface and it supports up to 1024 physical SAS / SATA devices. The next figures describe the connectors for this adapter.
Intel® Storage Adapters RS3P4GF016J and RS3P4QF160J Hardware User Guide 4.2.2 Intel® Storage Adapter RS3P4GF016J Dimensions The next figure shows the dimensions for the Intel Storage Adapter RS3P4GF016J in millimeters, without the PCI bracket. Figure 4. Intel® Storage Adapter RS3P4GF016J Dimensions...
• Relative humidity range is 20–80% non-condensing. • Temperature range: 0–+55 °C. List of non-operating conditions (while in storage or in transit) for the Intel Storage Adapter RS3P4GF016J: • Relative humidity range is 5–95% non-condensing. • Temperature range: -45–+105 °C.
Intel® Storage Adapters RS3P4GF016J and RS3P4QF160J Hardware User Guide Connector Pinout The Intel Storage Adapter RS3P4QF160J has two standard female SFF-8654 (SlimSAS* 8i) connectors to connect to a data cable. The connector pinout follows the SFF-9402 specification. SFF-9402 defines how to share sideband signals between SAS and PCIe (with NVMe).
SlimSAS to 2x MiniSAS HD, and one 860-mm long SlimSAS to 2x MiniSAS HD. The next figures show the connection diagram for SAS / SATA drives between the Intel Storage Adapter RS3P4QF160J and the backplanes for a 2U Intel Server System M50CYP and a 2U Intel® Server System R2000WF.
SAS-Compatible Intel® Storage Expander Configuration for the Intel® Storage Adapter RS3P4QF160J The SAS ports of the Intel Storage Adapters RS3P4QF160J and RS3P4GF016J are divided into two separate SAS domains: Domain 1 and Domain 2. One or two SAS connectors within a common domain can be cabled to a single SAS-compatible Intel storage expander card when cabling the storage adapter to a SAS expander.
Intel® Storage Adapters RS3P4GF016J and RS3P4QF160J Hardware User Guide Figure 8. Intel® Storage Adapter RS3P4QF160J SAS Port Domain Identification Figure 9. Intel® Storage Adapter RS3P4GF016J SAS Port Domain Identification Supported SAS-compatible Intel storage expanders include several multiport MiniSAS HD (8643) connectors.
Intel® Storage Adapters RS3P4GF016J and RS3P4QF160J Hardware User Guide Figure 10. SAS Ports for the Intel® Storage Expander RES3TV360 Notes for the input cable configuration: • The SAS expander card identified above can support one (1) or two (2) input SAS port cables.
Intel® Storage Adapters RS3P4GF016J and RS3P4QF160J Hardware User Guide NVMe* Drive Support The Intel Storage Adapter RMS4PQF160J can support a variety of NVMe drive configurations. At launch, only four direct-attach common clock NVMe drives are supported. The support for NVMe drives is limited to the U.2 (SFF-8639) form factor, connected through a supported backplane using an SFF-8654 8i to SFF-8654 8i.
Intel® Storage Adapters RS3P4GF016J and RS3P4QF160J Hardware User Guide Figure 12. Intel® Storage Adapter RS3P4QF160J Card Connection to the 1U Intel® Server System M50CYP Backplane for Direct-Attach NVMe* Drives...
ESD can occur without the user feeling a shock while working inside the system chassis or while improperly handling electronic devices like processors, memory or other storage devices, and add-in cards. Intel recommends the following steps be taken when performing any procedures described within this document or while performing service to any computer system.
1. Intel storage adapter. 2. Low profile mounting bracket. 3. Attention document. Note: Intel storage products do not include SAS / SATA / NVMe data cables. Appropriate data cables may be included with the server system or must be purchased separately. 5.1.3...
Carefully route data cables back to the Intel storage adapter. Connect the data cables to the storage adapter card. 10. Reinstall the computer cover, and reconnect the AC power cords to the system. The hardware installation is now complete, and the Intel storage adapter is ready to be used.
Intended application. Intel RAID products are evaluated as information technology equipment (ITE) as part of Intel server chassis systems. These products are intended to be part of Intel server systems to be installed in offices, schools, computer rooms, and similar commercial-type locations.
Intel® Storage Adapters RS3P4GF016J and RS3P4QF160J Hardware User Guide 6.2.3 CE Certification (Europe) • EN 55032:2015+A11:2020 Class A. • BS EN 55032:2015+A11:2020 Class A. • AS/NZS CISPR 32:2015 Class A. • CISPR 32:2015+COR1:2016 Class A. • EN IEC 61000-3-2:2019 Class A.
EU REACH Regulation No. 1907/2006. Product Environmental Compliance Intel has a system in place to restrict the use of banned substances in accordance with worldwide regulatory requirements. A material declaration datasheet is available for Intel products. For more reference on material restrictions and compliance, view Intel’s Environmental Product Content Specification at...
A piece of hardware (such as a video monitor, drive, printer, or CD-ROM) used with a computer and under the devices control of the computer. SCSI peripherals are controlled through an Intel® RAID controller (host adapter). The interface required to transmit and receive data packets transferred across the serial bus.
Need help?
Do you have a question about the RS3P4GF016J and is the answer not in the manual?
Questions and answers