Installation Requirements; Tools And Parts; Location Requirements - Whirlpool 9761413 Installation Instructions Manual

30" (76.2 cm) freestanding and slide-in gas ranges
Table of Contents

Advertisement

Available languages

Available languages

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the safety instructions provided with any tools
listed here.
Tools needed
Tape measure
Flat-blade screwdriver
Phillips screwdriver
Level
Hand or electric drill
Hammer
Channel lock pliers
Pipe wrench
" combination wrench
" drive ratchet
" nut driver
" (3.2 mm) drill bit (for
wood floors)
Parts supplied
Check that all parts are included.
B
A. Anti-tip bracket
B. Plastic anchors (2)
C. #10 x
D. Rear vent (for slide-in models)
Brackets must be securely mounted to subfloor. Thickness of
flooring may require longer screws to anchor bracket to
subfloor. Longer screws are available from your local
hardware store.
Parts needed
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See "Electrical Requirements" and
"Gas Supply Requirements" sections.
†®TORX is a registered trademark of Textron Innovations Inc.
4

INSTALLATION REQUIREMENTS

Marker or pencil
Masking tape
Pipe-joint compound
resistant to LP gas
" (4.8 mm) carbide-tipped
masonry drill bit (for
concrete/ceramic floors)
Noncorrosive leak-detection
solution
For LP/Natural Gas
Conversions
½" combination wrench
7 mm combination wrench
7 mm nut driver
®†
Size T20 TORX
screwdriver
A
C
D
" screws (2)

Location Requirements

IMPORTANT: Observe all governing codes and ordinances. Do
not obstruct flow of combustion and ventilation air.
It is the installer's responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located on the oven frame behind
the storage drawer panel.
The range should be located for convenient use in the
kitchen.
Recessed installations must provide complete enclosure of
the sides and rear of the range.
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
All openings in the wall or floor where range is to be installed
must be sealed.
Do not seal the range to the side cabinets.
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see "Install Anti-Tip
Bracket" section.
Grounded electrical supply is required. See "Electrical
Requirements" section. Proper gas supply connection must
be available. See "Gas Supply Requirements" section.
Contact a qualified floor covering installer to check that the
floor covering can withstand at least 200°F (93°C).
Use an insulated pad or ¼" (0.64 cm) plywood under range if
installing range over carpeting.
IMPORTANT: Some cabinet and building materials are not
designed to withstand the heat produced by the oven for baking
and self-cleaning. Check with your builder or cabinet supplier to
make sure that the materials used will not discolor, delaminate or
sustain other damage.
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the
current standards CAN/CSA-A240-latest edition, or with local
codes.
Mobile home installations require:
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the standards
listed above.

Advertisement

Table of Contents
loading

Table of Contents