Hide thumbs Also See for MG2000:

Advertisement

Owners's Manual
MG2000
Tachometer
IS0208
rev. A ecr#5028 11/17/04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MG2000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Faria MG2000

  • Page 1 Owners’s Manual MG2000 ™ Tachometer IS0208 rev. A ecr#5028 11/17/04...
  • Page 2 Index Figure 1 Default screens page 1 Description page 1 Normal Mode page 2 Contrast and Lighting page 2 Displayed Functions page 3 Default screen 1 page 3 Default screen 2 page 3 Default screen 3 page 3 Default screen 4 page 4 Figure 2 Screen Sequence page 4...
  • Page 3 “screens” can engine water pressure. be configured as the user wishes. As The MG2000™ provides a Faria Bus received, the screens are configured output to allow use of various 5, 4, and 2 as shown in Figure 1.
  • Page 4 Press the “Mode” button to exit the Normal Mode “screen selection mode” and return to When the MG2000™ is turned on, normal mode or do not push any buttons the unit enters “Self Test” mode. The for 4 seconds and the current screen will screen will display “The Self Test Mode...
  • Page 5 EDIT function: “Fuel Tank Displayed Functions Size”; and “Fuel Tank Full” OR “Amount MG2000™ Tachometer of Fuel”. The default “Fuel Tank Size” is The tachometer is a digital instrument with 0. The operator must set the Fuel Tank the appearance of an analog instrument.
  • Page 6 Screen “4” Screen “1” Screen “2” Screen “3” This screen displays fault conditions based on engine data received from the ECU or alarms based on internally set alarm points. Engine alarms from Screen “4” the ECU will be displayed as “Check Engine !”...
  • Page 7 Page 5...
  • Page 8 ������ �������� �� ��� setting the values for “Fuel Tank Size” ������� ���������� and either “Fuel Tank Full” or “Amount of Fuel” in the MG2000 Tachometer. ™ ���� ���� “Fuel Left” is calculated based on the ����...
  • Page 9 Functions that are set or adjusted in the The “Edit” mode is used to adjust or set “Edit” mode the values of numerous functions and options in the MG2000. The procedure 1. Select Default Screen. below specifies the steps to be taken 2. Reset Fuel Used.
  • Page 10 Reset Reset Fuel Used Fuel Used Press & Hold “UP” & “DOWN” for 2 sec to reset “fuel used” to zero (0) Automatically resets fuel used to zero and returns to “Edit mode” Press “UP” or “DOWN” to select another function or “Mode”...
  • Page 11 Press “UP” / “DOWN” to set the amount of fuel Fuel known to be in the fuel tank. Adjust until the displayed volume matches the known amount of Amount fuel in the tank. When the volume is correctly set, press & hold XXX G “UP”...
  • Page 12 Press & Hold “UP” & “DOWN” for 2 sec to save selection for Screen 1, line 3 and advance to view new screen 1. Press “Mode” to exit with no change made Press & Hold “UP” & “DOWN” for 2 sec to save Display new Screen 1 an exit to Customer’s...
  • Page 13 > 60 psi Press “UP” / “DOWN” to select. When selected, press & hold “UP” & “DOWN” for 2 80 psi sec to save and return to “gauge range” selection 100 psi Select Select Coolant Temp Dial Coolant Temp Dial Press &...
  • Page 14 Set Trim DOWN Using the Trim control, set the trim to the full “DOWN” position Press DOWN Press “DOWN” button to save “DOWN” setting TRIM Press “UP” to recal “UP” if desired Repeat as necessary When complete, press & hold “UP” & “DOWN” for 2 sec to save and return to “Calibrate Trim Sender”...
  • Page 15 > Press “UP” / “DOWN” to select. When selected, press & hold “UP” & “DOWN” for 2 LITERS sec to save and return to select “units” Select Select Temperature Units Temperature Units Press & Hold “UP” & “DOWN” for 2 sec to select “temperature units”...
  • Page 16 Select Select Press “UP” / “DOWN” to select either the Standard or Other fuel tank selections. If Standard is selected, press & hold “UP” & Other Standard “DOWN” for 2 sec to go to the following selection screens. Fuel Fuel Tank If Other is selected, press &...
  • Page 17 Press & Hold “UP” & “DOWN” for 2 sec to select “fuel tank calibration” Press “UP” or “DOWN” to select another function Calibrate Ensure that fuel tank is as empty as possible Fuel EMPTY Press & Hold “UP” & “DOWN” for 2 sec to set empty calibration.
  • Page 18 Shallow warning Depth Sounder Warnings Deep warning Keel Offset Press & Hold “UP” & “DOWN” for 2 sec to select “warning or offset”. Press “UP” or “DOWN” to adjust the function Press & Hold “UP” & “DOWN” for 2 sec to select “warning or offset”.
  • Page 19: Alarm Mode

    Available Functions for Display The “alarm” screen appears only if an alarm condition exists. The alarm in J1708 / J1587 MG2000 condition may be a warning sent from Tachometer Screens the engine ECU or a “local” alarm such as “Low Fuel”. When an alarm condition The functions listed below can be occurs, the “Alarm Screen”...
  • Page 20: Engine Warnings

    Press “Mode” to turn off LED, silence alarm horn, and return to “Run” mode. Alarm will reactivate in 15 minutes but can continue to be deactivated as required. ENGINE WARNINGS Any engine alarm except “Engine Emergency CHECK Stop” ENGINE Red LED blinks Horn “beeps”...
  • Page 21 LOW COOLANT LEVEL COOLANT LEVEL WATER WATER FLOW FLOW WATER WATER IN FUEL FUEL CHARGE INDICATOR CHARGE INDICATOR PREHEAT PREHEAT INDICATOR INDICATOR HIGH HIGH BOOST PRESSURE BOOST PRESSURE REV LIMIT EXCEEDED LIMIT EXCEEDED EGR SYSTEM SYSTEM THROTTLE THROTTLE POSITION SENSOR POSITION SENSOR ENGINE...
  • Page 22 Copyright 2005 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the company. Faria® is the trademark of the Thomas G. Faria Corporation...

Table of Contents