Burcam 300828TW Installation Instructions Manual

Submersible sump pump

Advertisement

Available languages

Available languages

2190 Dagenais Blvd. West
Laval (Quebec)
Canada
H7L 5X9
see us at
Your pump has been carefully packaged at the
factory to prevent damage during shipping.
However, occasional damage may occur due to
rough handling. Carefully inspect your pump
for damages that could cause failures. Report any
damage to your carrier or your point of purchase.
NOTICE
This unit has been designed to
pump water only. This unit is
not designed for applications
involving salt water, brine or any
other liquids including petroleum
products. Use with salt, brine
or any other liquids including
petroleum products will void the
warranty.
ELECTRICAL CONNECTION
For pumping systems using more
than one pump, each pump
needs to be connected to its own
dedicated circuit protected by a
fuse or breaker. The use of dedicated
circuits will allow the other pumps
to continue functioning even if
the fuse or breaker of one of the
pumps trips .
Tel. : 514.337.4415
Fax : 514.337.4029
info@burcam.com
www.burcam.com
INSTALLATION
INSTRUCTIONS
SUBMERSIBLE
© 2024 BURCAM Printed in Canada 310343TW
MODEL
300828TW
SUMP PUMP
Please read these
instructions
carefully. Failure
to comply to
instructions and
designed
operation of
this system,
may void
the warranty.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 300828TW and is the answer not in the manual?

Questions and answers

Summary of Contents for Burcam 300828TW

  • Page 1 The use of dedicated circuits will allow the other pumps to continue functioning even if the fuse or breaker of one of the pumps trips . © 2024 BURCAM Printed in Canada 310343TW...
  • Page 2: Safety Instructions

    SAFETY INSTRUCTIONS This fine pump that you have just purchased is designed from the latest in material and workmanship. Before installation and operation, we recommend the following procedures : Check with your local electrical and plumbing codes to ensure you comply with the regulations.
  • Page 3 • Two (2) pumps have to be installed in the sump pit. The first pump as a primary pump and the second pump as the backup unit. • Burcam alarm system model 450455 has to be installed to advise you any malfunctions. • As sump pumps are electrically powered and activated so to prevent flooding, a Burcam battery powered back-up pump model 300403 has to be installed to evacuate the water.
  • Page 4: Maintenance

    SUMP PUMP APPLICATION (SEE DIAGRAM ON PAGE 5) Prepare your choice of discharge pipe. STEP 3 Install and position your submersible sump pump in the centre of your sump STEP 4 pit or basin and ensure that there is clearance to allow the float switch a free working area without obstructions (pipe, pit’s wall, power cord).
  • Page 5: Repair Parts

    Oil seal 310267 ‘‘O’’ ring 310268 Screw 310269 Cable cord and nut 310270 Handle 450447AG Vertical switch (not shown) 310271 Motor assembly 310410 Float support (not shown) Repair parts may be ordered your authorized point of sale of from BURCAM PUMPS...
  • Page 6 TROUBLE SHOOTING GUIDE CHECKLIST NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM THE RECEPTACLE. TROUBLE PROBABLE CAUSE ACTION Switch is off position Turn switch to on position Motor does not run.
  • Page 7: Instructions D'installation

    à des fusibles ou disjoncteurs indépendants. Ainsi, l’alimentation électrique d’une pompe ne sera pas interrompu si le fusible de l’autre pompe brûle ou si le disjoncteur de l’autre pompe se déclenche. © 2024 BURCAM Imprimé au Canada 310343TW...
  • Page 8: Conseils De Sécurité

    CONSEILS DE SÉCURITÉ : La pompe que vous venez d’acquérir est un produit fabriqué avec les meilleurs matériaux et par une main-d’oeuvre spécialisée. Veuillez suivre les instructions d’utilisation et prendre les précautions nécessaires pour votre sécurité : Consultez les normes de plomberie et d’électricité se rapportant à...
  • Page 9: Étapes D'installation

    • Comme les pompes de puisard fonctionnent à l’électricité, pour prévenir une inondation, une pompe d’urgence à batterie Burcam modèle 300403 doit être installée pour évacuer l’eau. La sélection de pompe et l’installation adéquate et conforme sont obligatoires pour respecter les règles et codes locaux.
  • Page 10 APPLICATION DE POMPE PUISARD (VOIR LE DIAGRAMME À LA PAGE 5) Préparez votre choix de tuyau d’évacuation. ÉTAPE 3 Positionner la pompe submersible au centre de la fosse ou du bassin et s’assurer ÉTAPE 4 que l’espace requis au mouvement de la flotte verticale est libre de tout obstacle (tuyau, mur du bassin, câble d’alimentation).
  • Page 11: Pièces De Rechange

    310269 Câble d’alimentation et adaptateur du câble 310270 Poignée 450453A Interrupteur vertical 310271 Assemblage moteur (non illustré) 310410 Support de flotte (non illustré) Les pièces de rechange peuvent être commandées de votre point de vente autorisé ou de POMPES BURCAM...
  • Page 12: Guide De Résolution Des Problèmes

    GUIDE DE RÉSOLUTION DES PROBLÈMES LORS D’AJUSTEMENT SUR DES APPAREILS ÉLECTRIQUES, TOUJOURS S’ASSURER QUE LE COURANT EST DÉBRANCHÉ. NE PAS SEULEMENT ENLEVER LE FUSIBLE OU METTRE LE DISJONCTEUR HORS TENSION. IL FAUT DÉBRANCHER LE CÂBLE D’ALIMENTATION DE LA PRISE. PROBLÈME CAUSE POSSIBLE ACTION Commutateur hors circuit Remttre en circuit...

Table of Contents