  • Page 1 SW300DC Swing Gate Opener User Manual...
  • Page 2: Table Of Contents

    CONTENTS: 1. Safety Instruction........................1 2. Packing List..........................2 3. Technical Parameters........................ 3 4. Installation............................ 4 4.1 Installation Drawing..........................4 4.2 Size of Main Machine and Mounting Bracket................4 4.2.1 Size of Main Machine........................4 4.2.2 Size of Mounting Bracket......................5 4.3 Installation Steps........................... 5 4.3.1 Preparation before Main Machine Installation................
  • Page 3: Safety Instruction

    Dear users, Thank you for choosing this product. Please read the manual carefully before assembling and using it. Please do not leave out the manual if you send this product to a third party. 1. Safety Instruction ● Please read this manual carefully before installation, in which involves with important information about installation、using、maintenance and safety.
  • Page 4: Packing List

    2. Packing List (Standard) Picture Name Quantity Main machine Manual release key Remote control Control box Wall bracket Front mounting bracket Connecting bracket Screw M8X25 Mounting screw (short) Screw M8×45...
  • Page 5: Technical Parameters

    Packing List (Optional) Picture Name Quantity Infrared sensor Wireless keypad Alarm lamp Electric lock Storage battery 3. Technical Parameters Model SW300DC Power supply 220V/50Hz;110V/60Hz Motor power Gate moving speed 18~22s / 90° Max.single-leaf weight 300kg Max.single-leaf length 2.5M Max.piston stroke 32cm Max.force...
  • Page 6: Installation

    14kg 4. Installation SW300DC swing gate opener is applicable to single leaf gate weight less than 300kg, and the length shorter than 2.5m. The drive mode adopts planetary transmission to combine with the screw rod transmission. This gate opener must be installed inside the enclosure or yard for protection.
  • Page 7: Size Of Mounting Bracket

    709.5mmMIN 1037.5mmMAX Figure 2 4.2.2 Size of Mounting Bracket Wall bracket Front mounting bracket Figure 3 4.3 Installation Steps 4.3.1 Preparation before Main Machine Installation a) Before installing the door opener, please confirm that the doors were installed correctly, please ensure that the door can be manually operated smoothly, and the door safety stopper can effectively prevent the door to continue moving.
  • Page 8: Accessory Installation

    One PVC pipe for motor and power cables, the other one for control cables. Mounting brackets fixing In order to install the SW300DC main machines firmly, it is recommended to use the expansion screws to fix the mounting brackets. 4.3.2 Accessory Installation a) Before installing the main machines, please install the wall bracket on the wall first, then fix the connecting bracket, finally install the front mounting bracket on the door.
  • Page 9: Main Machine Installation

    cable is over 1.5mm², sectional diameter of other cables is over 0.5mm². The cable length should be determined by users according to their installation situations. Note: The outlet on the PVC pipe should be downward in order to avoid the rain water flowing into the pipe along the cable.
  • Page 10 Note: Note: The The limit limit stopper stopper has has to to be be installed. installed. Note: Note: The The gate gate safety safety stopper stopper has has to to be installed installed (should (should be be prepared prepared by users users themselves) themselves)
  • Page 11 Note: Note: The The gate gate safety safety stopper stopper has has to to be installed installed (should (should be be prepared prepared by users users themselves) themselves) Install Install the the limit limit stopper stopper Figure 9 95° 100° SIZE(mm) 100°...
  • Page 12: Size Of Control Box

    4.3.4 Size of Control Box 170mm 78.75mm Figure 10 Warning To ensure safety and protect the machines, please install a gate stopper at the open limit  position when the door opens outward to prevent the gate from running over its travel. Meanwhile, to enable the 2 swings to close to its accurate limit position, please install a limit stopper at the close limit position (as shown in figure 9).
  • Page 13: Wiring And Debugging

    After installation, please check whether the mechanical property is good or not, whether gate  movement is flexible or not after unlocking, and whether the infrared sensor (optional) is installed correctly and effectively. 5. Wiring and Debugging 5.1 Wiring Instructions...
  • Page 14: Control Board Drawing And Instructions

    Battery Battery 220VAC 220VAC 24V(1) 24V(1) FUSE FUSE 5A/250V 5A/250V Transformer Transformer 12V(1) 12V(1) MAX 24Vac 24Vac AC IN IN +BATT- +BATT- MODE MODE S.D. S.D. SPEED SPEED OBSTD. OBSTD. S W 3 0 0 V 1 . 0 LOCK LOCK M2 M2 +12-...
  • Page 15 MAX 24Vac 24Vac AC IN IN +BATT- +BATT- MODE MODE S.D. S.D. SPEED SPEED OBSTD. OBSTD. S W 3 0 0 V 1 . 0 LOCK LOCK M2 M2 +12- +12- 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 Figure 12 Instructions: Terminal...
  • Page 16 9. Analog closing edge input (8K2 ohm) For protector connecting 10. Common Highest priority. It always stops motors and blocks 11. Stop input (NC) control unit activity unless this button is released. 12. Common Space-13-14. Power supply output 24V/12Vdc 250mA 12/24V 1A (fix on MOT2) 15-16.
  • Page 17 J1. Back up battery voltage selection The default is 24VDC.
  • Page 18 5.3 Inputs Status When the control unit is in standby. User can read inputs status on display: : Initial Display No input active. : Stop input active. : Photo stop input active. : Photocells input active. : Start input active. : Pedestrian input active.
  • Page 19: Travel Setting

    5.4 Travel Setting (VERY IMPORTANT) After the first time installation but before starting normal operation, one important step you have to take it to set the opening and closing limit stop positions for the running travel. Please unlock the actuator first, manually swing the 2 doors to fully opened position then lock the actuator.
  • Page 20: Control Board Settings

    Open/Close/Stop Open/Close/Stop Open Open Close Close Stop Stop Pedestrian Pedestrian single single channel channel four four channel channel remote remote remote remote (R1 mode) mode) Figure 13 5.7 Control Board Settings 5.7.1 Base Menu At the Initial display , push enter button TS2 once for at least 1 second to enter base menu. is on the display, with up/down it’s possible to select other functions of this menu.
  • Page 21 (with Automatic closing function.) To delete just one code, select Learn a remote on and push the learned channel1.Both motor control remote button removed, on the display is show “OK” for a while if operation is done. Learn a remote on channel2. Learning/ removing Single motor control (motor2) To delete all codes, select...
  • Page 22 5.7.2 Advance Menu At the Initial display ,push enter button till on the display is shown . With up/down it’s possible to select all items In this menu. To exit this menu select or push up/down together. After 2 minutes without actions, control unit exits itself from this menu. Option Menu Default/Attention...
  • Page 23 Not set Enable opening analogue edge Not set Enable closing analogue edge Disable Enable Enabling this function it’s possible to Disable Automatic remote insert transmitters without learning accessing base menu. Refer “Automatic transmitters learning”. Disable Disable Low power mode Enable Disable Enable In this menu you can Disable...
  • Page 24: Infrared Photocell Connection (Optional)

    disable (block stop) disable Series motor limit enable (Magnetic Limit) Table 5 5.8 Infrared Photocell Connection (Optional) Before connecting the infrared photocell, please remove the jumper wire between terminal 5 and 6 first. Infrared photocell function: To protect passengers or property from clipping, during gate closing, once infrared photocell ray is cut, the gate will open immediately.
  • Page 25: Solar Panel Connection (Optional)

    +BATT- +BATT- AC IN IN +SOLAR- +SOLAR- S.D. S.D. SPEED SPEED OBSTD. OBSTD. I D 2 1 0 V 1 . 0 OUT LPW LOCK LOCK +24 +12 +12 COM 1 31 4 1 41 5 1 51 6 1 61 7 1 71 8 1 81 9 1 92 0...
  • Page 26: Solar Panel

    Solar Solar panel panel Solar Solar charger charger S TR S TR S PD S PD P HS P HS ST P ST P - + Storage Storage battery battery - + Figure 15...
  • Page 27: Others

    6. Others 6.1 Maintenance Check whether the gate operates normally every month. For the sake of safety, each gate is suggested to be equipped with infrared protector, and regular inspection is required as well. Before installation and operation of the gate opener, please read all instructions carefully. We reserve the right to change the instruction without prior notice.
  • Page 28 1.Motor output force is not 1.Check whether the transformer The gate moves to the enough. power is normal, if not, change the middle position to stop or 2.Sensitivity of obstacle is too transformer. reverse. high. 2.Adjust the TR2. 3.Gate meets obstacle. 3.Remove the obstacle.
  • Page 29: Warranty

    Warranty Warranty Ordinance 1. To repair against this warranty card and invoice during the warranty period. 2. Warranty period: 1 year after the date of invoice. 3. Without unauthorized dismantling, any product broken or damage due to quality problem, we’ll offer the repair service for free or replace for free.