4 fan speeds and timer
Activated carbon pre-filter
True HEPA* filtration system + UV-C light and ionizer
Footnotes:
* True HEPA filter efficiency of 99.985% with respect to particles 0.3 μm in diameter indicated by third-party testing conducted pursuant to method BS EN 1822-3.
BEFORE OPERATING THE AIR PURIFIER:
When moving the air purifier, always lift unit by the carrying handle located on back.
OPERATING THE AIRPURIFIER
Important note: When the unit is not in use, switch it off, and unplug it.
FILTER REPLACE INDICATOR
The power LED light flickering continuously indicates that it is time to replace the filter. Replace the filter according to the directions then press the ON/OFF(Filter reset) button and hold for 5 seconds to restart the system. The light will stop flickering.
*The 3 in 1 HEPA filter will last approximately 3-6 months depending on usage and air quality.
The air purifier should be cleaned at least once every month and the pre-filter attached to the HEPA Filter should be cleaned every month. More frequent cleaning may be required depending on environmental conditions.
FILTERS
Clean with the brush attachment of your vacuum cleaner. This will remove lint and dirt.
NOTE:
The 3 in 1 filter is one filter system. The multiple layers include: the carbon coated pre-filter and HEPA Filter.
Hg LAMP CONTAINS MERCURY
Manage in accordance with Spills, Disposal and Site Cleanup Requirements. In case of breakage, follow clean-up procedures provided by contacts below.
www.epa.gov/cflcleanup
1-866-284-4010
MAINTENANCE PRECAUTIONS
Use a clean, dry, soft cloth to wipe the external surface of the unit.
NOTE: Do NOT stick any foreign objects or your fingers inside of the unit. CAUTION: Do NOT use gasoline, benzene, thinner, harsh cleaners, etc. on and/or in the unit while cleaning as they will damage the product.
NEVER use alcohol or other solvents.
Before carrying out any of the following service checks, unplug the unit from the mains.
Insufficient air flow | Check that the filters are clean Check for any obstructions in the air inlet and outlet |
Unit will not start | Check the power supply and electric fuses. Check that the Front Cover is latched firmly in place. Check that the Filter is firmly in place. |
Excessive noise | Check for any foreign objects in contact with the fan. The filter may be clogged and ready for replacement. The foam sealing gaskets have been installed incorrectly. Uneven positioning. |
Why is the replace filter light blinking? | The replace filter light is set to automatically go off after 4,320 hours. It is only a reminder to check the filter to keep the air purifier running smoothly. To reset the light, please hold down the power button while the unit is on for 5 seconds. |
How often should I change filters? | The filter replacement frequency varies greatly on environment. We recommend checking the pre-filter monthly. Vacuum off any visible dust and hair on the pre-filter or replace the pre-filter with a new one. For HEPA filter replacement, we recommend going by looking at the backside of the filter. Once the backside turns a grayish color indicating that dirt has penetrated to the last layer of the filter, we recommend changing it. |
Why does my air purifier smell? | The scent is usually from the carbon pre-filter. You can test if this is the case by running the filter without the pre-filter attached. If this scent is bothersome, we recommend using our gray pre-filter without carbon coating. Please contact us for more information. |
What is the difference between your 2 filters you offer? | We offer two filters for this air purifier, the IC-5018- Filter and IC-5018-Hepa-C-Filter. The IC-5018-Filter features a HEPA filter with a pre-filter coated with activated carbon. The IC-5018-Hepa-C-Filter features a HEPA filter with a honeycomb array of pelletized carbon and a plain washable pre-filter. It has much more activated carbon content and is optimized for VOC gas and odor removal. |
When should I change the bulb? | The bulb should be changed yearly for optimum performance. |
My unit no longer powers on, what should I do? | First, please check another outlet to see if it is a problem with the outlet. Second, please make sure the two hooks at the bottom of the door are intact and not broken off. If they are broken off, the safety sensor will not be depressed and the unit will not power on. Please contact us to replace the door. |
How do I tell if my UV lamp is wo rking? | Please remove the filter and replace the door. You should see a blue glow from the UV bulb when looking into the unit from the air intake on the right side front of the unit. Please only look at the UV light from a distance and do not look at it directly for any length of time. |
READ AND SAVE THESE INSTRUCTIONS
Failure to comply with the warnings listed below may result in electric shock or serious injury.
This product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
Rated Voltage: AC 110V-240V, 60Hz
Rated Power: 55W
Noise Level: From 30dB(LOW) to 55dB(TURBO)
UV Light: Wave length: 254 nanometers
Lamp life: Approx. 20,000 hours
Dimensions: 12.34(L) x 6.25(W) x 17.75(H) inches