Elkay ENLZS8WSAP-W1 1A Series Installation & Use Manual
Elkay ENLZS8WSAP-W1 1A Series Installation & Use Manual

Elkay ENLZS8WSAP-W1 1A Series Installation & Use Manual

Bottle filling stations & coolers

Advertisement

Patent zurn-elkay.com/patents
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov
AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov
ENLZS8WSAP-W1_1A, ENLZS8WSMP-W1_1A, ENLZS8WSSP-W1_1A
Enhanced
INSTALLATION & USE MANUAL
LZ
Series Bottle Filling Stations & Coolers
SMART CONNECTED-READY
Pre-installation steps
Install Zurn Gateway and Register Product in
plumbSMART
1. Install Zurn Gateway (required and sold separately)
per the gateway instructions manual, if an existing
gateway is not within communication range.
2. Be sure the gateway is powered on and connected
(per gateway installation instructions) prior to
installing your bottle filler. Serial number located
on back of the Gateway, is required to register the
gateway to your tenant.
3. If you have not already set up an tenant account
and your administrator access, request at
844-987-67 37 or
zurnconnectedproducts@zurn.com
4. Log into plumbsmart.zurn.com
5. Register Connected product in plumbSMART
using plumbSMART Registration ID located on
plumbSMART ID Registration Label, (See Fig.
8a, Pg. 6). (Watch How-To videos to get started.
Located in the support section inside the portal.)
Page 1
2000002202 (Rev. B - 02/25)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ENLZS8WSAP-W1 1A Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Elkay ENLZS8WSAP-W1 1A Series

  • Page 1 ID Registration Label, (See Fig. 8a, Pg. 6). (Watch How-To videos to get started. Located in the support section inside the portal.) Patent zurn-elkay.com/patents WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov Page 1 2000002202 (Rev.
  • Page 2 ENLZS8WSAP-W1_1A, ENLZS8WSMP-W1_1A, ENLZS8WSSP-W1_1A Fig. 1 2000002202 (Rev. B - 02/25) Page 2...
  • Page 3 ENLZS8WSAP-W1_1A, ENLZS8WSMP-W1_1A, ENLZS8WSSP-W1_1A INSTRUCTIONS FOR REMOVING WRAPPER Fig. B(ii) Fig. B(i) 1) Remove the two security screws (size T25) from the front panel. (see Fig B(i)) NOTE: SCREW THREADS INTO BUSHING WHILE ANGLED. DO NOT ATTEMPT TO THREAD SCREW INTO BUSHING HORIZONTALLY. 2) Gently pull the wrapper down and rotate the wrapper to a downward position (see Fig B(ii)).
  • Page 4: Programming Button

    7) Connect electrical power by plugging in unit’s power cord. 8) Turn on water supply and flush filter to purge air and fine carbon particles from filter before use. Visit elkay.com/fi ltration for additional details. Also run water through bottle filler until all air is removed and water flow is clear.
  • Page 5 ENLZS8WSAP-W1_1A, ENLZS8WSMP-W1_1A, ENLZS8WSSP-W1_1A FIG. 2 FIG. 3 Secure cooler frame to wall by installing (2) screws and washers (not supplied). Fig. 4 Lay gasket along back of bottle filler mounting plate. Align BF and lay on cooler basin. Fig. 5 Attach the 3/8 water line into the bulkhead fitting.
  • Page 6: Wall Mounting Plate

    ENLZS8WSAP-W1_1A, ENLZS8WSMP-W1_1A, ENLZS8WSSP-W1_1A Fig. 6 Fig. 7 Connect the bottle filler electrical harness. (Gasket removed from bottle filler for clarity) plumbSMART registration ID Fig. 8a MOUNTING BOLT HOLES (6) WALL MOUNTING PLATE Fig. 8 BOTTLE FILLING UNIT 2000002202 (Rev. B - 02/25) Page 6...
  • Page 7 ENLZS8WSAP-W1_1A, ENLZS8WSMP-W1_1A, ENLZS8WSSP-W1_1A 115V Refrigerated Wiring Diagram with Alpha/Numeric Display Connected-Ready - Enhanced Bottle Filler Wire End-point harness Board Fig. 9 WARNING • INGESTION HAZARD: This product contains a button cell or coin battery. • DEATH or serious injury can occur if ingested. •...
  • Page 8 Blue indicates normal operation, no immediate attention needed. Red indicates immediate attention 3/8” required to maintain proper function. Water Inlet Scan for trouble shooting and to sign up for auto replenishment of authentic Elkay filters. Fig. 14 WATERSENTRY Filter Detail ® WATERSENTRY FILTER PARTS LIST ®...
  • Page 9: Temperature Control

    ENLZS8WSAP-W1_1A, ENLZS8WSMP-W1_1A, ENLZS8WSSP-W1_1A Note: Danger! Electrical shock hazard. Disconnect power before servicing unit. Service Instructions Lower and Upper Shroud To access the refrigeration system and plumbing connections, Remove two (2) screws from front of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars, regulator, solenoid valve or other components located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires and water tube.
  • Page 10 ENLZS8WSAP-W1_1A, ENLZS8WSMP-W1_1A, ENLZS8WSSP-W1_1A 2000002202 (Rev. B - 02/25) Page 10...
  • Page 11: Error Description

    ENLZS8WSAP-W1_1A, ENLZS8WSMP-W1_1A, ENLZS8WSSP-W1_1A Enhanced EZH2O Error Codes Error Error Description Corrective Action Code Bottle filler area obstructed • Remove obstruction. • Clean lens on IR sensor • Unplug unit for at least 30 seconds and restart • If error repeats, replace IR sensor E013 Missing or Incompatible Filter •...
  • Page 12: Filter Location

    ENLZS8WSAP-W1_1A, ENLZS8WSMP-W1_1A, ENLZS8WSSP-W1_1A Pictured is unit only without bottle filler. Note: Danger! Electrical shock hazard. Disconnect power before servicing unit. Uses HFC-134A refrigerant Filter Location See Fig. 12 12 or 13 See Fig. 15 21, 24 Fig. 16 2000002202 (Rev. B - 02/25) Page 12...
  • Page 13 1000004573 Kit - Solenoid 120V (BF) 1000004573 Kit - Solenoid 120V (BF) 2000002090 2000002089 Nameplate - Elkay Filtered (AW) Nameplate - Elkay Filtered (MB) 2000002072 Kit - Top Cover Assy (BF) (AW) 2000002071 Kit - Top Cover Assy (BF) (MB)
  • Page 14 115V PARTS LIST FOR LZS8WSSP-W1 ATTENTION: If the product serial number is before 190424189, please refer to archived PART ITEM DESCRIPTION documents section of Elkay.com for the most accurate parts list. (www.elkay.com/archived-documents) Hanger Bracket 28401C 0000001337 Basin - Stainless Steel...
  • Page 15: Fcc Compliance Statement

    ENLZS8WSAP-W1_1A, ENLZS8WSMP-W1_1A, ENLZS8WSSP-W1_1A FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment This device complies with Part 15 of the FCC Rules. Operation to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 16 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 PRINTED IN U.S.A. • ELKAY MANUFACTURING COMPANY • 1333 BUTTERFIELD ROAD • DOWNERS GROVE, IL 60515 • 630.574.8484 www.elkay.com 2000002202 (Rev. B - 02/25) Page 16...

Table of Contents