▶ Install the appliance into a cold-water circuit containing – a list entry (second level) water for human consumption (closed circuit). Table 1 ▶ The installation must only be carried out by an authorised contractor. Tronic Advanced – 6721888539 (2025/01)
Page 4
The work can only be carried out by a specialized and water supply is closed. authorized contractor that has to carry out all the work and ▶ Prepare the water connections before the electrical immediately eliminate the detected faults. connections. Tronic Advanced – 6721888539 (2025/01)
Use as intended The appliance was designed to heat potable water. Please observe all country-specific regulations, guidelines and standards for potable water. The appliance should only be installed in sanitary installations with a pressurised circuit. Tronic Advanced – 6721888539 (2025/01)
About the appliance Dimensions Fig. 1 Appliance dimensions in mm Fig. 2 Installation dimensions in mm [1] Cold water Inlet [2] Hot water Outlet Tronic Advanced – 6721888539 (2025/01)
[15] Appliance wall-mounting point Transportation and storage The appliance must be transported and stored in a dry, frost- The appliance heats the water as it circulates inside it. free location. When handling, ▶ Do not drop the appliance. Tronic Advanced – 6721888539 (2025/01)
White LED flashes Holiday mode active (only possible [6] Wi-Fi/Connectivity (1x every through the APP). The appliance does [7] Locked 4 seconds) not heat the water. [8] Handwashing operating mode [9] Operating mode Shower Table 2 Tronic Advanced – 6721888539 (2025/01)
Roughly 1.5 seconds Less than 3 seconds To select one of the operating modes, see chapter 4.5.1. 65 °C Roughly 1 second Roughly 1.5 seconds 68 °C Less than 1 second Roughly 1 second Table 4 Tronic Advanced – 6721888539 (2025/01)
▶ Clean the exterior with mild cleaning agents. 4.5.3 Fault history ▶ Clean the remains of dirt or limescale. To display the fault history: ▶ Press and hold the keys simultaneously until the fault history is shown on the display. Tronic Advanced – 6721888539 (2025/01)
In order to ensure the correct installation and operation of the appliance, please observe all regulations, technical guidelines and applicable national and regional directives. Fig. 7 Tronic Advanced – 6721888539 (2025/01)
▶ Purge the appliance completely before turning on the residual current device, by turning on the hot water tap completely and let the water circulate in the appliance for 1 minute. Tronic Advanced – 6721888539 (2025/01)
▶ Install the appliance in a room where the ambient temperature never drops below 0 °C. ▶ Do not install the appliance in locations with an altitude Fig. 10 Remove the front fascia above 2000 m above sea level. Tronic Advanced – 6721888539 (2025/01)
Page 14
Fig. 13 Fig. 11 Loosen the screw ▶ Remove the hydraulic block from the back. ▶ Loosen and remove the front fascia of the appliance. Fig. 14 Fig. 12 ▶ Turn around the hot water pipe. Tronic Advanced – 6721888539 (2025/01)
Fig. 16. ▶ Only use taps and accessories with capacity to operate in a closed circuit (under pressure). Fig. 16 Horizontal water connections [1] Cold water inlet (G ½") [2] Hot water outlet (G ½") Tronic Advanced – 6721888539 (2025/01)
▶ Separate the fixing parts. Fig. 18 ▶ Use the back of the appliance as a hole pattern. ▶ Support the appliance on the cold water accessory to Fig. 20 facilitate marking on the wall. Tronic Advanced – 6721888539 (2025/01)
Fig. 22 Electrical installation of the appliance It is possible to connect the power cable in three different positions; • Upper connection • Lower Connection • Lower connection for short cables Fig. 24 Tronic Advanced – 6721888539 (2025/01)
Page 18
If the appliance is not securely fixed to the wall, ▶ Use the screws to fix the spacers to the wall. If the appliance is not perpendicular to the wall, ▶ Use spacers at the bottom to level the appliance. Tronic Advanced – 6721888539 (2025/01)
Page 19
Aquastop system (TR .001 A), the additional bushing supplied with the appliance must be installed. ▶ Install the additional bushing to allow for the correct installation of Aquastop (Image 30). Fig. 30 Additional bushing After levelling the appliance, Tronic Advanced – 6721888539 (2025/01)
▶ Position the water inlet and outlet pipes into the sealing membrane. Fig. 33 ▶ Place the bonded washers onto the water connections. Fig. 32 ▶ Tighten the water connections. ▶ Check if there are leaks. Tronic Advanced – 6721888539 (2025/01)
▶ Tighten the water connection. Fig. 37 ▶ Press the two tabs and remove the Aquastop protection Fig. 34 device. ▶ Place the Aquastop in the hole in the sealing membrane. Fig. 38 Fig. 35 Tronic Advanced – 6721888539 (2025/01)
5.10.1 Setting maximum temperature ▶ Use Jumper J5 to set the maximum temperature of the appliance, according to the table below. Max. Temperature Jumper: J5 Maximum Temperature 42 °C ▶ Remove jumper J5. Table 5 Setting maximum temperature Tronic Advanced – 6721888539 (2025/01)
The layout of the electrical cables must be positioned in accordance with the images below. Fig. 43 Lower connection Lower connection for short cables Fig. 44 Lower connection for short cables Tronic Advanced – 6721888539 (2025/01)
Page 24
▶ Pass the power cable through the cable conduit guaranteeing a minimum of 10 mm of insulating cover for the electrical cable. Fig. 46 Fig. 49 Tronic Advanced – 6721888539 (2025/01)
Lower connection short cables ▶ Position the electrical cable so that it is not in the way of where the appliance's central screw is inserted and it allows the appliance cover to be correctly fitted. Fig. 53 Tronic Advanced – 6721888539 (2025/01)
▶ Give the customer all the printed documents for the appliance. Removing/Replacing the flow limiter The appliance needs a minimum water pressure and flow rate to start ( Tab. 10.1). Tronic Advanced – 6721888539 (2025/01)
NOTICE Damage to the appliance! ▶ For safe and environmentally compatible operation, maintenance and cleaning must be carried out at least once every 12 months in accordance with chapter 8. Tronic Advanced – 6721888539 (2025/01)
The display shows an Malfunction in the ▶ Close and open the hot water tap. error code “E..”. appliance. If the error remains; ▶ Contact customer support. Table 6 Problems Tronic Advanced – 6721888539 (2025/01)
AS/NZS 3000. 2) The first time the appliance is commissioned, the minimum water flow rate should be 3.5 l/min. 3) The pressure drop in the mixer should be added to this value. Table 7 Technical characteristics Tronic Advanced – 6721888539 (2025/01)
Or via post to: Used appliances Robert Bosch Aust Pty Ltd, Attention TT Warranty Department, Used appliances contain valuable materials that can be Locked Bag 66, Clayton South, Victoria, 3169. recycled. Claims received by post will take longer to process and we The various assemblies can be easily dismantled.
"Important Note: Mandatory Australian Consumer Law statement” above. Warranty Period and Coverage The following is a list of the classes of products sold by Bosch which are covered by this voluntary warranty, and the warranty periods which apply in each case. Product Group...
Page 32
Operation, use, or maintenance of the Products otherwise than in accordance with instructions provided for the Products by Bosch, or without reasonable care; connection to water from a bore, dam or swimming pool; connection to faulty equipment, such as damaged valves; foreign matter in the water supply;...
Page 33
Australia, you can post details of your claim to Robert Bosch (Australia) Pty Ltd, Attn HC Warranty Department, Locked Bag 66, Clayton Sth, Victoria, 3169. Claims received by post will take longer to process and we encourage you to call. Bosch may refer you to one of its Bosch Warranty Authorised Service Dealers.
Page 34
It is therefore critical that all warranty claims are promptly submitted to Bosch as soon as the product fails, and in any event before the end of the warranty period.
Page 36
Robert Bosch (Australia) Pty Ltd Thermotechnology Division 1555 Centre Road Clayton Victoria 3168 Australia Phone: 1300 30 70 37 Fax: 1300 30 70 38 www.bosch-homecomfort.au New Zealand Phone: 0800 54 33 52 Fax: 0800 54 33 55 www.bosch-homecomfort.nz...
Need help?
Do you have a question about the Tronic Advanced and is the answer not in the manual?
Questions and answers